转子磁通定向感应电机铁损辨识及失谐评估

E. Levi, M. Sokola, A. Boglietti, M. Pastorelli
{"title":"转子磁通定向感应电机铁损辨识及失谐评估","authors":"E. Levi, M. Sokola, A. Boglietti, M. Pastorelli","doi":"10.1109/PESC.1996.548788","DOIUrl":null,"url":null,"abstract":"Iron loss, as a source of detuned operation of rotor flux oriented induction machines, has attracted much attention. Appropriate mathematical expressions, that enable evaluation of detuning, have become available and performance deterioration due to iron loss has been evaluated for rated speed operation in the constant flux region. The available studies are based on the measurement of iron loss with sinusoidal supply of rated frequency. This paper at first describes an experimental procedure for determination of iron loss and hence an equivalent iron loss resistance over the frequency range of interest. The procedure is based on no-load tests with PWM inverter supply and it can be executed during commissioning of the drive. The second part of the paper evaluates detuning introduced by iron loss in a rotor flux oriented induction machine, utilising the experimentally determined values of equivalent iron loss resistance. The emphasis is placed on operation in the braking region and on operation in the field weakening region. It is shown that detuning characteristics in the braking region differ from those valid in the motoring region. Detuning in the field-weakening region is found to significantly exceed the one at rated flux, rated speed operation, especially if the machine runs at high speeds with light loads. Finally, a modified rotor flux estimator, that enables compensation of the iron loss, is introduced and verified by simulation.","PeriodicalId":19979,"journal":{"name":"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference","volume":"9 1","pages":"1555-1561 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1996-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Iron loss identification and detuning evaluation in rotor flux oriented induction machines\",\"authors\":\"E. Levi, M. Sokola, A. Boglietti, M. Pastorelli\",\"doi\":\"10.1109/PESC.1996.548788\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Iron loss, as a source of detuned operation of rotor flux oriented induction machines, has attracted much attention. Appropriate mathematical expressions, that enable evaluation of detuning, have become available and performance deterioration due to iron loss has been evaluated for rated speed operation in the constant flux region. The available studies are based on the measurement of iron loss with sinusoidal supply of rated frequency. This paper at first describes an experimental procedure for determination of iron loss and hence an equivalent iron loss resistance over the frequency range of interest. The procedure is based on no-load tests with PWM inverter supply and it can be executed during commissioning of the drive. The second part of the paper evaluates detuning introduced by iron loss in a rotor flux oriented induction machine, utilising the experimentally determined values of equivalent iron loss resistance. The emphasis is placed on operation in the braking region and on operation in the field weakening region. It is shown that detuning characteristics in the braking region differ from those valid in the motoring region. Detuning in the field-weakening region is found to significantly exceed the one at rated flux, rated speed operation, especially if the machine runs at high speeds with light loads. Finally, a modified rotor flux estimator, that enables compensation of the iron loss, is introduced and verified by simulation.\",\"PeriodicalId\":19979,\"journal\":{\"name\":\"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"9 1\",\"pages\":\"1555-1561 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1996.548788\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1996.548788","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

铁损是引起转子磁通定向异步电机失谐的主要原因之一,引起了人们的广泛关注。已经有了适当的数学表达式,可以评估失谐,并且已经评估了在恒通量区域额定速度运行时由于铁损失而导致的性能下降。现有的研究都是基于额定频率正弦电源下铁损耗的测量。本文首先描述了一个测定铁损的实验程序,从而在感兴趣的频率范围内得到等效铁损电阻。该程序基于PWM逆变器供电的空载测试,可以在驱动器调试期间执行。本文第二部分利用实验确定的等效铁损电阻值,对转子磁通定向感应电机中铁损引起的失谐进行了评价。重点介绍了制动区和弱磁场区的运行情况。结果表明,制动区域的失谐特性不同于运动区域的失谐特性。弱磁场区域的失谐明显超过额定磁通、额定转速运行时的失谐,特别是在机器以轻负荷高速运行时。最后,介绍了一种改进的转子磁链估计器,实现了铁损补偿,并进行了仿真验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Iron loss identification and detuning evaluation in rotor flux oriented induction machines
Iron loss, as a source of detuned operation of rotor flux oriented induction machines, has attracted much attention. Appropriate mathematical expressions, that enable evaluation of detuning, have become available and performance deterioration due to iron loss has been evaluated for rated speed operation in the constant flux region. The available studies are based on the measurement of iron loss with sinusoidal supply of rated frequency. This paper at first describes an experimental procedure for determination of iron loss and hence an equivalent iron loss resistance over the frequency range of interest. The procedure is based on no-load tests with PWM inverter supply and it can be executed during commissioning of the drive. The second part of the paper evaluates detuning introduced by iron loss in a rotor flux oriented induction machine, utilising the experimentally determined values of equivalent iron loss resistance. The emphasis is placed on operation in the braking region and on operation in the field weakening region. It is shown that detuning characteristics in the braking region differ from those valid in the motoring region. Detuning in the field-weakening region is found to significantly exceed the one at rated flux, rated speed operation, especially if the machine runs at high speeds with light loads. Finally, a modified rotor flux estimator, that enables compensation of the iron loss, is introduced and verified by simulation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信