基于振动传感器阵列的变压器绕组松动诊断

Yuhang Shi, Wefgel Lu, Fan Zhang, Y. Dang, C. Zhan, S. Ji, Ziqian Zhu
{"title":"基于振动传感器阵列的变压器绕组松动诊断","authors":"Yuhang Shi, Wefgel Lu, Fan Zhang, Y. Dang, C. Zhan, S. Ji, Ziqian Zhu","doi":"10.1109/CMD.2018.8535884","DOIUrl":null,"url":null,"abstract":"The vibration of the oil-tank can reflect the mechanical condition of transformer internal windings and cores. Although there were several studies about the vibration of the transformer, most of them do not take into account the inherent connection between different measuring points, which results in insufficient utilization of vibration information. To conquer this shortcoming, a fault diagnosis method for transformer winding looseness based on vibration sensor array is proposed. An array measurement system was set up, and a suitable measurement method was put forward. Because the voltage fluctuation of the transformer in actual operation is very small while the load current fluctuates greatly and the winding vibration is mainly influenced by the current. Load tests were conducted on a single-phase transformer. The influence of the current on the vibration characteristics was studied. Different levels of winding looseness were set up and their vibration characteristics were studied. The matrix distance was used to judge the deviation of the array signal. The results show that the array signal does not change with the current change. When the windings are loosened, the array distance of the array signal increases significantly. It provides a new idea for the diagnosis of the mechanical fault of transformer windings based on vibration signals.","PeriodicalId":6529,"journal":{"name":"2018 Condition Monitoring and Diagnosis (CMD)","volume":"65 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Diagnosis of Transformer Winding Looseness Based on Vibration Sensor Array\",\"authors\":\"Yuhang Shi, Wefgel Lu, Fan Zhang, Y. Dang, C. Zhan, S. Ji, Ziqian Zhu\",\"doi\":\"10.1109/CMD.2018.8535884\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The vibration of the oil-tank can reflect the mechanical condition of transformer internal windings and cores. Although there were several studies about the vibration of the transformer, most of them do not take into account the inherent connection between different measuring points, which results in insufficient utilization of vibration information. To conquer this shortcoming, a fault diagnosis method for transformer winding looseness based on vibration sensor array is proposed. An array measurement system was set up, and a suitable measurement method was put forward. Because the voltage fluctuation of the transformer in actual operation is very small while the load current fluctuates greatly and the winding vibration is mainly influenced by the current. Load tests were conducted on a single-phase transformer. The influence of the current on the vibration characteristics was studied. Different levels of winding looseness were set up and their vibration characteristics were studied. The matrix distance was used to judge the deviation of the array signal. The results show that the array signal does not change with the current change. When the windings are loosened, the array distance of the array signal increases significantly. It provides a new idea for the diagnosis of the mechanical fault of transformer windings based on vibration signals.\",\"PeriodicalId\":6529,\"journal\":{\"name\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"volume\":\"65 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CMD.2018.8535884\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Condition Monitoring and Diagnosis (CMD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CMD.2018.8535884","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

油箱的振动可以反映变压器内部绕组和铁芯的机械状况。虽然已有一些关于变压器振动的研究,但大多没有考虑到不同测点之间的内在联系,导致振动信息利用不足。针对这一缺点,提出了一种基于振动传感器阵列的变压器绕组松动故障诊断方法。建立了阵列测量系统,并提出了合适的测量方法。因为变压器在实际运行中电压波动很小,而负载电流波动很大,绕组振动主要受电流影响。负载试验在单相变压器上进行。研究了电流对振动特性的影响。设置了不同程度的绕组松动,并对其振动特性进行了研究。利用矩阵距离来判断阵列信号的偏差。结果表明,阵列信号不随电流变化而变化。当绕组松动时,阵列信号的阵列距离明显增大。为基于振动信号的变压器绕组机械故障诊断提供了一种新的思路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnosis of Transformer Winding Looseness Based on Vibration Sensor Array
The vibration of the oil-tank can reflect the mechanical condition of transformer internal windings and cores. Although there were several studies about the vibration of the transformer, most of them do not take into account the inherent connection between different measuring points, which results in insufficient utilization of vibration information. To conquer this shortcoming, a fault diagnosis method for transformer winding looseness based on vibration sensor array is proposed. An array measurement system was set up, and a suitable measurement method was put forward. Because the voltage fluctuation of the transformer in actual operation is very small while the load current fluctuates greatly and the winding vibration is mainly influenced by the current. Load tests were conducted on a single-phase transformer. The influence of the current on the vibration characteristics was studied. Different levels of winding looseness were set up and their vibration characteristics were studied. The matrix distance was used to judge the deviation of the array signal. The results show that the array signal does not change with the current change. When the windings are loosened, the array distance of the array signal increases significantly. It provides a new idea for the diagnosis of the mechanical fault of transformer windings based on vibration signals.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信