湿式雾化过程中影响出药率的因素

A. Coates, C. F. MacNeish, L. Lands, A. A. Smountas, D. Meisner, S. Kelemen, E. Vadas
{"title":"湿式雾化过程中影响出药率的因素","authors":"A. Coates, C. F. MacNeish, L. Lands, A. A. Smountas, D. Meisner, S. Kelemen, E. Vadas","doi":"10.1089/JAM.1998.11.101","DOIUrl":null,"url":null,"abstract":"ABSTRACT Jet nebulization in an unvented nebulizer is a complex phenomenon which includes the physical fracturing of a liquid film into droplets of aerosol and the evaporative losses that accompany the interaction between the nebulizing gas and the nebulizer solution. The process of nebulization continues until a certain minimal residual volume (dead volume) is reached. This dead volume is determined by the loss of the liquid volume of the aerosol and the amount of evaporative losses, the latter partially determined by the relative humidity of the nebulizing gas. Evaporative losses are maximized if the nebulizing gas is free of water vapor and are minimized if it is wet, as is usually the case when room air is compressed but not dried. In order to explain differences in nebulizer output between dry and wet nebulizing gases, a mathematical model was developed that allows the calculation of the total output of drug, the liquid volume of aerosol, and the water loss due to evaporation, all with respect to tim...","PeriodicalId":14879,"journal":{"name":"Journal of Aerosol Medicine-deposition Clearance and Effects in The Lung","volume":"16 1","pages":"101-111"},"PeriodicalIF":0.0000,"publicationDate":"1998-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":"{\"title\":\"Factors Influencing the Rate of Drug Output During the Course of Wet Nebulization\",\"authors\":\"A. Coates, C. F. MacNeish, L. Lands, A. A. Smountas, D. Meisner, S. Kelemen, E. Vadas\",\"doi\":\"10.1089/JAM.1998.11.101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Jet nebulization in an unvented nebulizer is a complex phenomenon which includes the physical fracturing of a liquid film into droplets of aerosol and the evaporative losses that accompany the interaction between the nebulizing gas and the nebulizer solution. The process of nebulization continues until a certain minimal residual volume (dead volume) is reached. This dead volume is determined by the loss of the liquid volume of the aerosol and the amount of evaporative losses, the latter partially determined by the relative humidity of the nebulizing gas. Evaporative losses are maximized if the nebulizing gas is free of water vapor and are minimized if it is wet, as is usually the case when room air is compressed but not dried. In order to explain differences in nebulizer output between dry and wet nebulizing gases, a mathematical model was developed that allows the calculation of the total output of drug, the liquid volume of aerosol, and the water loss due to evaporation, all with respect to tim...\",\"PeriodicalId\":14879,\"journal\":{\"name\":\"Journal of Aerosol Medicine-deposition Clearance and Effects in The Lung\",\"volume\":\"16 1\",\"pages\":\"101-111\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Aerosol Medicine-deposition Clearance and Effects in The Lung\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/JAM.1998.11.101\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Aerosol Medicine-deposition Clearance and Effects in The Lung","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/JAM.1998.11.101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

在无通气的雾化器中,喷射雾化是一种复杂的现象,它包括液体薄膜物理破裂成气溶胶液滴,以及伴随着雾化气体和雾化器溶液之间相互作用的蒸发损失。雾化过程继续进行,直到达到一定的最小残余体积(死体积)。这个死体积是由气溶胶的液体体积损失和蒸发损失量决定的,蒸发损失量部分由雾化气体的相对湿度决定。如果雾化气体不含水蒸气,蒸发损失最大,如果是湿的,蒸发损失最小,通常是房间空气被压缩但不干燥的情况。为了解释干式和湿式雾化气体在雾化器输出量上的差异,建立了一个数学模型,可以计算出药物的总输出量、气溶胶的液体体积和由于蒸发而造成的水分损失,所有这些都与时间有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Factors Influencing the Rate of Drug Output During the Course of Wet Nebulization
ABSTRACT Jet nebulization in an unvented nebulizer is a complex phenomenon which includes the physical fracturing of a liquid film into droplets of aerosol and the evaporative losses that accompany the interaction between the nebulizing gas and the nebulizer solution. The process of nebulization continues until a certain minimal residual volume (dead volume) is reached. This dead volume is determined by the loss of the liquid volume of the aerosol and the amount of evaporative losses, the latter partially determined by the relative humidity of the nebulizing gas. Evaporative losses are maximized if the nebulizing gas is free of water vapor and are minimized if it is wet, as is usually the case when room air is compressed but not dried. In order to explain differences in nebulizer output between dry and wet nebulizing gases, a mathematical model was developed that allows the calculation of the total output of drug, the liquid volume of aerosol, and the water loss due to evaporation, all with respect to tim...
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信