由监测导管引起的股动脉假性动脉瘤感染。

J. Kjartansson, J. Swedenborg, B. Nylén
{"title":"由监测导管引起的股动脉假性动脉瘤感染。","authors":"J. Kjartansson, J. Swedenborg, B. Nylén","doi":"10.1097/00004630-198605000-00029","DOIUrl":null,"url":null,"abstract":"A patient suffering from severe burns developed a mycotic aneurysm in the femoral artery as a result of insertion of a monitoring catheter. Treatment with antibiotics and repeated arterial surgery failed and a below knee amputation was finally performed. The use of monitoring intraarterial catheters in burn patients is to be avoided, because of impaired immunity, wound infection and septicaemia in this type of patient which could facilitate the development of septic aneurysm. If, however, a monitoring catheter is mandatory, it should be inserted and cared for by highly experienced staff who appreciate the risks involved. A peripheral site of insertion should reduce morbidity.","PeriodicalId":77684,"journal":{"name":"Burns, including thermal injury","volume":"27 1","pages":"213-5"},"PeriodicalIF":0.0000,"publicationDate":"1986-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Infected pseudo-aneurysm of the femoral artery caused by a monitoring catheter.\",\"authors\":\"J. Kjartansson, J. Swedenborg, B. Nylén\",\"doi\":\"10.1097/00004630-198605000-00029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A patient suffering from severe burns developed a mycotic aneurysm in the femoral artery as a result of insertion of a monitoring catheter. Treatment with antibiotics and repeated arterial surgery failed and a below knee amputation was finally performed. The use of monitoring intraarterial catheters in burn patients is to be avoided, because of impaired immunity, wound infection and septicaemia in this type of patient which could facilitate the development of septic aneurysm. If, however, a monitoring catheter is mandatory, it should be inserted and cared for by highly experienced staff who appreciate the risks involved. A peripheral site of insertion should reduce morbidity.\",\"PeriodicalId\":77684,\"journal\":{\"name\":\"Burns, including thermal injury\",\"volume\":\"27 1\",\"pages\":\"213-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Burns, including thermal injury\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/00004630-198605000-00029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Burns, including thermal injury","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00004630-198605000-00029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一个患有严重烧伤的病人,由于植入监测导管,在股动脉中形成了霉菌性动脉瘤。抗生素治疗和反复动脉手术失败,最后进行膝盖以下截肢。应避免在烧伤患者中使用监测动脉内导管,因为这类患者的免疫功能受损、伤口感染和败血症可能促进败血性动脉瘤的发展。然而,如果监测导管是强制性的,则应由经验丰富的工作人员插入和护理,他们了解所涉及的风险。植入周边部位应能降低发病率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Infected pseudo-aneurysm of the femoral artery caused by a monitoring catheter.
A patient suffering from severe burns developed a mycotic aneurysm in the femoral artery as a result of insertion of a monitoring catheter. Treatment with antibiotics and repeated arterial surgery failed and a below knee amputation was finally performed. The use of monitoring intraarterial catheters in burn patients is to be avoided, because of impaired immunity, wound infection and septicaemia in this type of patient which could facilitate the development of septic aneurysm. If, however, a monitoring catheter is mandatory, it should be inserted and cared for by highly experienced staff who appreciate the risks involved. A peripheral site of insertion should reduce morbidity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信