{"title":"基于软件的DVFS技术为并行应用节省电力","authors":"C. Chaitra","doi":"10.1109/ICPCSI.2017.8392197","DOIUrl":null,"url":null,"abstract":"Scientific parallel applications need more computing power, to produce such computing power we need high end hardware. This hardware consumes more power and generates lot of heat. Cooling system is required to make sure that the hardware is healthy otherwise it will be prone to failure. As a result cost of data center operation will be more and it will not be environmental friendly. By reducing the power consumption we can reduce the cost as well as make data center environmental friendly. This work proposes a software based Dynamic Voltage and Frequency Scaling technique which helps in reducing the power consumption by parallel applications. To evaluate our technique we used popular NAS parallel benchmark and observed that up to 40% energy saving is achieved.","PeriodicalId":6589,"journal":{"name":"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)","volume":"47 1","pages":"2648-2651"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Software based DVFS technique for parallel applications to conserve the power\",\"authors\":\"C. Chaitra\",\"doi\":\"10.1109/ICPCSI.2017.8392197\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Scientific parallel applications need more computing power, to produce such computing power we need high end hardware. This hardware consumes more power and generates lot of heat. Cooling system is required to make sure that the hardware is healthy otherwise it will be prone to failure. As a result cost of data center operation will be more and it will not be environmental friendly. By reducing the power consumption we can reduce the cost as well as make data center environmental friendly. This work proposes a software based Dynamic Voltage and Frequency Scaling technique which helps in reducing the power consumption by parallel applications. To evaluate our technique we used popular NAS parallel benchmark and observed that up to 40% energy saving is achieved.\",\"PeriodicalId\":6589,\"journal\":{\"name\":\"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)\",\"volume\":\"47 1\",\"pages\":\"2648-2651\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPCSI.2017.8392197\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPCSI.2017.8392197","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

科学并行应用需要更多的计算能力,要产生这样的计算能力,我们需要高端硬件。这种硬件消耗更多的电力并产生大量的热量。冷却系统需要确保硬件是健康的,否则它将容易出现故障。因此,数据中心的运营成本将会更高,而且对环境也不友好。通过降低功耗,我们可以降低成本,并使数据中心环保。这项工作提出了一种基于软件的动态电压和频率缩放技术,有助于降低并行应用的功耗。为了评估我们的技术,我们使用了流行的NAS并行基准测试,并观察到节能高达40%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Software based DVFS technique for parallel applications to conserve the power
Scientific parallel applications need more computing power, to produce such computing power we need high end hardware. This hardware consumes more power and generates lot of heat. Cooling system is required to make sure that the hardware is healthy otherwise it will be prone to failure. As a result cost of data center operation will be more and it will not be environmental friendly. By reducing the power consumption we can reduce the cost as well as make data center environmental friendly. This work proposes a software based Dynamic Voltage and Frequency Scaling technique which helps in reducing the power consumption by parallel applications. To evaluate our technique we used popular NAS parallel benchmark and observed that up to 40% energy saving is achieved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信