{"title":"也门亚丁省药房供应的药用人血清白蛋白制剂的质量评价","authors":"Ahmed Thabet Ahmed Al-Sarhe, Mutea’a Edrous Saeed","doi":"10.47372/ejua-ba.2023.2.247","DOIUrl":null,"url":null,"abstract":"Human serum albumin(HAS) is important for the body, as it performs a set of functions such as maintaining osmotic pressure inside cells, transporting drugs and ions, and others. The fraudulent process of such preparations may lead to the deterioration of the patient's health condition and sometimes death. In the current study, two types of albumin preparations that were not authorized by the Yemeni ministry of health and entered the country through smuggling were studied. The results of the study proved that these preparations were exposed to high temperatures, so that denaturation of HSA, in addition to the oxidation process of the substance N-acetyl-tryptophan. The reverse phase (RP) high-performance liquid chromatography (HPLC) method to assess HSA, a gradient elution (a combination of acetonitrile/water, supplemented with 0.1% (v/v) trifluoroacetic acid) was used to separate samples on a C4 (n-butyl-coated silica) column. Two main peaks were observed at 4.970 and 10.850 min, representing the stabilizer N-acetyl-tryptophan (N-Ac-Trp) and HSA respectively. Validation of the method demonstrated that HSA can be determined in an accurate and precise manner, in a range between 0.1 and 5g/ml, without the interference of matrix ingredients. The limit of detection (LOD) and lower limit of quantification (LLOQ) values were 0.23 and 0.72 g /ml, respectively. The results of the study proved that these preparations do not meet the quality specifications of the World Health Organization, in addition to exposure to temperatures and bad storage leading to oxidation. The results of the analysis of all samples were less than the permissible limit because each sample must contain 10 grams per 50 ml.","PeriodicalId":11552,"journal":{"name":"Electronic Journal of University of Aden for Basic and Applied Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"QUALITY EVALUATION OF PHARMACEUTICAL HUMAN SERUM ALBUMIN PREPARATIONS AVAILABLE IN PHARMACIES IN ADEN GOVERNORATE - YEMEN\",\"authors\":\"Ahmed Thabet Ahmed Al-Sarhe, Mutea’a Edrous Saeed\",\"doi\":\"10.47372/ejua-ba.2023.2.247\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Human serum albumin(HAS) is important for the body, as it performs a set of functions such as maintaining osmotic pressure inside cells, transporting drugs and ions, and others. The fraudulent process of such preparations may lead to the deterioration of the patient's health condition and sometimes death. In the current study, two types of albumin preparations that were not authorized by the Yemeni ministry of health and entered the country through smuggling were studied. The results of the study proved that these preparations were exposed to high temperatures, so that denaturation of HSA, in addition to the oxidation process of the substance N-acetyl-tryptophan. The reverse phase (RP) high-performance liquid chromatography (HPLC) method to assess HSA, a gradient elution (a combination of acetonitrile/water, supplemented with 0.1% (v/v) trifluoroacetic acid) was used to separate samples on a C4 (n-butyl-coated silica) column. Two main peaks were observed at 4.970 and 10.850 min, representing the stabilizer N-acetyl-tryptophan (N-Ac-Trp) and HSA respectively. Validation of the method demonstrated that HSA can be determined in an accurate and precise manner, in a range between 0.1 and 5g/ml, without the interference of matrix ingredients. The limit of detection (LOD) and lower limit of quantification (LLOQ) values were 0.23 and 0.72 g /ml, respectively. The results of the study proved that these preparations do not meet the quality specifications of the World Health Organization, in addition to exposure to temperatures and bad storage leading to oxidation. The results of the analysis of all samples were less than the permissible limit because each sample must contain 10 grams per 50 ml.\",\"PeriodicalId\":11552,\"journal\":{\"name\":\"Electronic Journal of University of Aden for Basic and Applied Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electronic Journal of University of Aden for Basic and Applied Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47372/ejua-ba.2023.2.247\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electronic Journal of University of Aden for Basic and Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47372/ejua-ba.2023.2.247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
人血清白蛋白(HAS)对人体很重要,因为它执行一系列功能,如维持细胞内的渗透压,运输药物和离子等。这类制剂的伪造过程可能导致病人健康状况恶化,有时甚至死亡。在目前的研究中,研究了两种未经也门卫生部批准并通过走私进入该国的白蛋白制剂。研究结果证明,这些制剂暴露在高温下,使HSA变性,氧化过程中除了物质n -乙酰-色氨酸。采用反相(RP)高效液相色谱(HPLC)法测定HSA,采用梯度洗脱(乙腈/水组合,添加0.1% (v/v)三氟乙酸),在C4(正丁基包覆二氧化硅)柱上分离样品。在4.970 min和10.850 min出现两个主要峰,分别代表稳定剂n -乙酰基色氨酸(N-Ac-Trp)和HSA。验证结果表明,在不受基质成分干扰的情况下,测定HSA的准确度在0.1 ~ 5g/ml范围内。检测限为0.23 g /ml,定量限为0.72 g /ml。研究结果证明,这些制剂不符合世界卫生组织的质量标准,此外,暴露于温度和不良储存导致氧化。所有样品的分析结果均低于允许限量,因为每个样品每50毫升必须含有10克。
QUALITY EVALUATION OF PHARMACEUTICAL HUMAN SERUM ALBUMIN PREPARATIONS AVAILABLE IN PHARMACIES IN ADEN GOVERNORATE - YEMEN
Human serum albumin(HAS) is important for the body, as it performs a set of functions such as maintaining osmotic pressure inside cells, transporting drugs and ions, and others. The fraudulent process of such preparations may lead to the deterioration of the patient's health condition and sometimes death. In the current study, two types of albumin preparations that were not authorized by the Yemeni ministry of health and entered the country through smuggling were studied. The results of the study proved that these preparations were exposed to high temperatures, so that denaturation of HSA, in addition to the oxidation process of the substance N-acetyl-tryptophan. The reverse phase (RP) high-performance liquid chromatography (HPLC) method to assess HSA, a gradient elution (a combination of acetonitrile/water, supplemented with 0.1% (v/v) trifluoroacetic acid) was used to separate samples on a C4 (n-butyl-coated silica) column. Two main peaks were observed at 4.970 and 10.850 min, representing the stabilizer N-acetyl-tryptophan (N-Ac-Trp) and HSA respectively. Validation of the method demonstrated that HSA can be determined in an accurate and precise manner, in a range between 0.1 and 5g/ml, without the interference of matrix ingredients. The limit of detection (LOD) and lower limit of quantification (LLOQ) values were 0.23 and 0.72 g /ml, respectively. The results of the study proved that these preparations do not meet the quality specifications of the World Health Organization, in addition to exposure to temperatures and bad storage leading to oxidation. The results of the analysis of all samples were less than the permissible limit because each sample must contain 10 grams per 50 ml.