集成自对准参比电极的微针尖电极阵列的制备

Bum-Ryul Maeng, Seung-Ki Lee, S. Bai, Jaehyoung Park
{"title":"集成自对准参比电极的微针尖电极阵列的制备","authors":"Bum-Ryul Maeng, Seung-Ki Lee, S. Bai, Jaehyoung Park","doi":"10.1109/TRANSDUCERS.2015.7181185","DOIUrl":null,"url":null,"abstract":"This paper presents a novel microtip-based electrode array with the reference electrode around tips. A microelectromechanical systems process for a microtip electrode array has been developed using DRIE and RIE combination process. The conductive microtip with high aspect ratio, small apex radius and the height of tens of micron scale is insulated except the tip ends. The tips are closely surrounded by the self-aligned reference electrode. The whole process was completed with a single photography mask. The fabricated microtip-based electrode array was successfully verified with the cyclic voltammetry measurements and characterized with the measurement of photosynthetic reaction of chlorella cell using microtip electrode array.","PeriodicalId":6465,"journal":{"name":"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fabrication of microtip electrode array integrated with self-aligned reference electrode\",\"authors\":\"Bum-Ryul Maeng, Seung-Ki Lee, S. Bai, Jaehyoung Park\",\"doi\":\"10.1109/TRANSDUCERS.2015.7181185\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel microtip-based electrode array with the reference electrode around tips. A microelectromechanical systems process for a microtip electrode array has been developed using DRIE and RIE combination process. The conductive microtip with high aspect ratio, small apex radius and the height of tens of micron scale is insulated except the tip ends. The tips are closely surrounded by the self-aligned reference electrode. The whole process was completed with a single photography mask. The fabricated microtip-based electrode array was successfully verified with the cyclic voltammetry measurements and characterized with the measurement of photosynthetic reaction of chlorella cell using microtip electrode array.\",\"PeriodicalId\":6465,\"journal\":{\"name\":\"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TRANSDUCERS.2015.7181185\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2015.7181185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种基于微针尖的新型电极阵列,参考电极围绕针尖。采用DRIE和RIE相结合的工艺,开发了一种微针尖电极阵列的微机电系统工艺。高宽高比、小尖端半径和几十微米尺度高度的导电微针尖除针尖两端外均绝缘。尖端被自对准参比电极紧密包围。整个过程是用一个摄影面具完成的。利用循环伏安法对制备的微针尖电极阵列进行了验证,并利用微针尖电极阵列对小球藻细胞的光合反应进行了表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fabrication of microtip electrode array integrated with self-aligned reference electrode
This paper presents a novel microtip-based electrode array with the reference electrode around tips. A microelectromechanical systems process for a microtip electrode array has been developed using DRIE and RIE combination process. The conductive microtip with high aspect ratio, small apex radius and the height of tens of micron scale is insulated except the tip ends. The tips are closely surrounded by the self-aligned reference electrode. The whole process was completed with a single photography mask. The fabricated microtip-based electrode array was successfully verified with the cyclic voltammetry measurements and characterized with the measurement of photosynthetic reaction of chlorella cell using microtip electrode array.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信