单相电网系统的功率注入

Fauzan Ismail, A. Effendi, Witrionanda Witrionanda
{"title":"单相电网系统的功率注入","authors":"Fauzan Ismail, A. Effendi, Witrionanda Witrionanda","doi":"10.26418/ELKHA.V11I1.30932","DOIUrl":null,"url":null,"abstract":"This paper deals with power injection on single phase grid connected inverter. The simple method is introduced to understand the concept of grid connected systems. A phase Lock Loop (PLL) method estimates the phase-angle of grid system. The output of PLL is used to defines Iref , and the current of inverter becomes a feedback (IL). Both current are derived to produce PWM using current mode controller method. As long as the grid system on fault condition like voltage distortion, therefore the single-phase inverter that connected into the grid should change the role and keep stabilization. The voltages sag and swell are the possible conditions that occurred on a power system. Voltage Sag is an event where the line voltage decreases from the nominal line-voltage for a short period of time. Voltage swell is the event when the line voltage increase from the nominal line voltage. By using PSIM software, the injection and absorption of power into a grid system is verified during a voltage sag, swell, and normal. The simulation shows voltage grid vg, current inverter iinv, current grid, active power P, reactive power Q. The waveform of the measured parameter is analized to define the role of inverter toward grid. the The result shows performance of the proposed inverter to absorb reactive power during swell, and inject reactive power when sagging. ","PeriodicalId":32754,"journal":{"name":"Elkha Jurnal Teknik Elektro","volume":"41 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Power Injection on Single Phase Grid System\",\"authors\":\"Fauzan Ismail, A. Effendi, Witrionanda Witrionanda\",\"doi\":\"10.26418/ELKHA.V11I1.30932\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with power injection on single phase grid connected inverter. The simple method is introduced to understand the concept of grid connected systems. A phase Lock Loop (PLL) method estimates the phase-angle of grid system. The output of PLL is used to defines Iref , and the current of inverter becomes a feedback (IL). Both current are derived to produce PWM using current mode controller method. As long as the grid system on fault condition like voltage distortion, therefore the single-phase inverter that connected into the grid should change the role and keep stabilization. The voltages sag and swell are the possible conditions that occurred on a power system. Voltage Sag is an event where the line voltage decreases from the nominal line-voltage for a short period of time. Voltage swell is the event when the line voltage increase from the nominal line voltage. By using PSIM software, the injection and absorption of power into a grid system is verified during a voltage sag, swell, and normal. The simulation shows voltage grid vg, current inverter iinv, current grid, active power P, reactive power Q. The waveform of the measured parameter is analized to define the role of inverter toward grid. the The result shows performance of the proposed inverter to absorb reactive power during swell, and inject reactive power when sagging. \",\"PeriodicalId\":32754,\"journal\":{\"name\":\"Elkha Jurnal Teknik Elektro\",\"volume\":\"41 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Elkha Jurnal Teknik Elektro\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26418/ELKHA.V11I1.30932\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elkha Jurnal Teknik Elektro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26418/ELKHA.V11I1.30932","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文研究了单相并网逆变器的功率注入问题。介绍了一种简单的方法来理解并网系统的概念。一种锁相环估计电网系统相角的方法。锁相环的输出用于定义Iref,逆变器的电流成为反馈(IL)。这两个电流都是通过电流模式控制器的方法来产生PWM的。只要电网系统处于电压畸变等故障状态,那么接入电网的单相逆变器就应该改变作用,保持稳定。电压跌落和电压膨胀是电力系统中可能发生的情况。电压骤降是指线路电压在短时间内从标称线路电压下降。电压膨胀是指线路电压高于标称线路电压时发生的事件。通过使用PSIM软件,可以在电压跌落、膨胀和正常时验证电网系统的电力注入和吸收情况。仿真显示了电压栅格vg、逆变器电流iinv、电流栅格、有功功率P、无功功率q。通过对实测参数波形的分析,明确了逆变器对栅格的作用。结果表明,该逆变器具有膨胀时吸收无功、下垂时注入无功的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power Injection on Single Phase Grid System
This paper deals with power injection on single phase grid connected inverter. The simple method is introduced to understand the concept of grid connected systems. A phase Lock Loop (PLL) method estimates the phase-angle of grid system. The output of PLL is used to defines Iref , and the current of inverter becomes a feedback (IL). Both current are derived to produce PWM using current mode controller method. As long as the grid system on fault condition like voltage distortion, therefore the single-phase inverter that connected into the grid should change the role and keep stabilization. The voltages sag and swell are the possible conditions that occurred on a power system. Voltage Sag is an event where the line voltage decreases from the nominal line-voltage for a short period of time. Voltage swell is the event when the line voltage increase from the nominal line voltage. By using PSIM software, the injection and absorption of power into a grid system is verified during a voltage sag, swell, and normal. The simulation shows voltage grid vg, current inverter iinv, current grid, active power P, reactive power Q. The waveform of the measured parameter is analized to define the role of inverter toward grid. the The result shows performance of the proposed inverter to absorb reactive power during swell, and inject reactive power when sagging. 
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
23
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信