一个真正的全双工32通道0.135cm3神经接口

Dejan Rozgić, Vahagn Hokhikyan, Wenlong Jiang, Sina Basir-Kazeruni, H. Chandrakumar, Weiyu Leng, D. Markovic
{"title":"一个真正的全双工32通道0.135cm3神经接口","authors":"Dejan Rozgić, Vahagn Hokhikyan, Wenlong Jiang, Sina Basir-Kazeruni, H. Chandrakumar, Weiyu Leng, D. Markovic","doi":"10.1109/BIOCAS.2017.8325193","DOIUrl":null,"url":null,"abstract":"We propose a novel neuromodulation (NM) interface with true 100mV pp linear input range that enables concurrent neural sensing and stimulation. It includes a flexible 4-driver-to-32-contact stimulator that can deliver up to 3.1mA per driver (total 12.4mA) and a 32-channel sensing unit. This 32-channel interface meets design requirements of human-quality implants at unprecedented electronic miniaturization (20x reduction) as compared to prior art. It offers major new clinical perspectives: always-on sensing for enhanced closed-loop therapy, multi-channel arbitrary stimulation waveforms with user-friendly programming, and a high spatial resolution neural interface for precise target localization.","PeriodicalId":73279,"journal":{"name":"IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference","volume":"24 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A true full-duplex 32-channel 0.135cm3 neural interface\",\"authors\":\"Dejan Rozgić, Vahagn Hokhikyan, Wenlong Jiang, Sina Basir-Kazeruni, H. Chandrakumar, Weiyu Leng, D. Markovic\",\"doi\":\"10.1109/BIOCAS.2017.8325193\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We propose a novel neuromodulation (NM) interface with true 100mV pp linear input range that enables concurrent neural sensing and stimulation. It includes a flexible 4-driver-to-32-contact stimulator that can deliver up to 3.1mA per driver (total 12.4mA) and a 32-channel sensing unit. This 32-channel interface meets design requirements of human-quality implants at unprecedented electronic miniaturization (20x reduction) as compared to prior art. It offers major new clinical perspectives: always-on sensing for enhanced closed-loop therapy, multi-channel arbitrary stimulation waveforms with user-friendly programming, and a high spatial resolution neural interface for precise target localization.\",\"PeriodicalId\":73279,\"journal\":{\"name\":\"IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference\",\"volume\":\"24 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2017.8325193\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2017.8325193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

我们提出了一种新颖的神经调节(NM)接口,具有真正的100mV pp线性输入范围,可以同时实现神经传感和刺激。它包括一个灵活的4驱动器到32触点刺激器,每个驱动器可提供高达3.1mA(总12.4mA)和一个32通道传感单元。与现有技术相比,这种32通道接口以前所未有的电子小型化(缩小20倍)满足人体质量植入物的设计要求。它提供了主要的新临床前景:用于增强闭环治疗的始终在线传感,具有用户友好编程的多通道任意刺激波形,以及用于精确定位目标的高空间分辨率神经接口。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A true full-duplex 32-channel 0.135cm3 neural interface
We propose a novel neuromodulation (NM) interface with true 100mV pp linear input range that enables concurrent neural sensing and stimulation. It includes a flexible 4-driver-to-32-contact stimulator that can deliver up to 3.1mA per driver (total 12.4mA) and a 32-channel sensing unit. This 32-channel interface meets design requirements of human-quality implants at unprecedented electronic miniaturization (20x reduction) as compared to prior art. It offers major new clinical perspectives: always-on sensing for enhanced closed-loop therapy, multi-channel arbitrary stimulation waveforms with user-friendly programming, and a high spatial resolution neural interface for precise target localization.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信