标准化人血清蛋白溶液对一系列微生物病原体和毒素的抗体反应性:与新鲜冷冻血浆的比较

H. Schmidt, R. Lissner, W. Struff, O. Thamm, H. Karch
{"title":"标准化人血清蛋白溶液对一系列微生物病原体和毒素的抗体反应性:与新鲜冷冻血浆的比较","authors":"H. Schmidt, R. Lissner, W. Struff, O. Thamm, H. Karch","doi":"10.1046/J.1526-0968.2002.00347.X","DOIUrl":null,"url":null,"abstract":"In this study, we compared a standardized solution of human serum protein (HSP) and fresh frozen plasma (FFP) with regard to the antibody specificity against a number of microbial pathogens and some important pathogenicity factors of bacterial pathogens. Due to the clinical use of HSP and FFP for therapeutical plasma exchange, we have chosen a spectrum of microbial pathogens for serological analysis that is critical in clinical settings. With the enzyme-linked immunosorbent assay technique, we could show that HSP contains marked IgG antibody reactivity against antigens of Escherichia coli, Campylobacter jejuni, Enterobacter sakazakii, Proteus mirabilis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Staphylococcus aureus, S. epidermidis, Streptococcus pneumoniae, Enterococcus faecalis, Chlamydia pneumoniae, and Candida albicans. Although no IgM antibodies against the pathogens tested could be detected in HSP, moderate IgA reactivity was found against 4 of 12 microbial antigens. Immunoblot analysis demonstrated specific IgA and IgG responses against the endoproteinase Glu-C and the superantigens enterotoxin A and B of S. aureus, the IgA-protease of Neisseria gonorrhoeae, and Shiga toxin 2 of enterohemorrhagic E. coli. By using 3 different HSP batches in parallel, we could demonstrate antibody reactivity against important microbial pathogens and toxins. This antibody profile is essentially more homogeneous than that of 3 batches of FFP.","PeriodicalId":79755,"journal":{"name":"Therapeutic apheresis : official journal of the International Society for Apheresis and the Japanese Society for Apheresis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Antibody reactivity of a standardized human serum protein solution against a spectrum of microbial pathogens and toxins: comparison with fresh frozen plasma.\",\"authors\":\"H. Schmidt, R. Lissner, W. Struff, O. Thamm, H. Karch\",\"doi\":\"10.1046/J.1526-0968.2002.00347.X\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, we compared a standardized solution of human serum protein (HSP) and fresh frozen plasma (FFP) with regard to the antibody specificity against a number of microbial pathogens and some important pathogenicity factors of bacterial pathogens. Due to the clinical use of HSP and FFP for therapeutical plasma exchange, we have chosen a spectrum of microbial pathogens for serological analysis that is critical in clinical settings. With the enzyme-linked immunosorbent assay technique, we could show that HSP contains marked IgG antibody reactivity against antigens of Escherichia coli, Campylobacter jejuni, Enterobacter sakazakii, Proteus mirabilis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Staphylococcus aureus, S. epidermidis, Streptococcus pneumoniae, Enterococcus faecalis, Chlamydia pneumoniae, and Candida albicans. Although no IgM antibodies against the pathogens tested could be detected in HSP, moderate IgA reactivity was found against 4 of 12 microbial antigens. Immunoblot analysis demonstrated specific IgA and IgG responses against the endoproteinase Glu-C and the superantigens enterotoxin A and B of S. aureus, the IgA-protease of Neisseria gonorrhoeae, and Shiga toxin 2 of enterohemorrhagic E. coli. By using 3 different HSP batches in parallel, we could demonstrate antibody reactivity against important microbial pathogens and toxins. This antibody profile is essentially more homogeneous than that of 3 batches of FFP.\",\"PeriodicalId\":79755,\"journal\":{\"name\":\"Therapeutic apheresis : official journal of the International Society for Apheresis and the Japanese Society for Apheresis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic apheresis : official journal of the International Society for Apheresis and the Japanese Society for Apheresis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1046/J.1526-0968.2002.00347.X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic apheresis : official journal of the International Society for Apheresis and the Japanese Society for Apheresis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1046/J.1526-0968.2002.00347.X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

在这项研究中,我们比较了人血清蛋白(HSP)和新鲜冷冻血浆(FFP)的标准化溶液对多种微生物病原体和细菌病原体的一些重要致病因子的抗体特异性。由于临床使用热休克蛋白和FFP进行治疗性血浆交换,我们选择了一组微生物病原体进行血清学分析,这在临床环境中至关重要。通过酶联免疫吸附试验技术,我们可以发现HSP对大肠杆菌、空肠弯曲杆菌、阪崎肠杆菌、奇迹变形杆菌、铜绿假单胞菌、肺炎克雷伯菌、金黄色葡萄球菌、表皮葡萄球菌、肺炎链球菌、粪肠球菌、肺炎衣原体和白色念珠菌抗原具有显著的IgG抗体反应性。虽然在HSP中未检测到针对病原菌的IgM抗体,但在12种微生物抗原中有4种具有中等程度的IgA反应性。免疫印迹分析显示,对金黄色葡萄球菌的内源性蛋白酶Glu-C和超抗原肠毒素A和B、淋病奈瑟菌的IgA蛋白酶和肠出血性大肠杆菌的志贺毒素2有特异性的IgA和IgG反应。通过平行使用3个不同批次的HSP,我们可以证明抗体对重要的微生物病原体和毒素的反应性。该抗体谱基本上比3批FFP的抗体谱更均匀。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Antibody reactivity of a standardized human serum protein solution against a spectrum of microbial pathogens and toxins: comparison with fresh frozen plasma.
In this study, we compared a standardized solution of human serum protein (HSP) and fresh frozen plasma (FFP) with regard to the antibody specificity against a number of microbial pathogens and some important pathogenicity factors of bacterial pathogens. Due to the clinical use of HSP and FFP for therapeutical plasma exchange, we have chosen a spectrum of microbial pathogens for serological analysis that is critical in clinical settings. With the enzyme-linked immunosorbent assay technique, we could show that HSP contains marked IgG antibody reactivity against antigens of Escherichia coli, Campylobacter jejuni, Enterobacter sakazakii, Proteus mirabilis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Staphylococcus aureus, S. epidermidis, Streptococcus pneumoniae, Enterococcus faecalis, Chlamydia pneumoniae, and Candida albicans. Although no IgM antibodies against the pathogens tested could be detected in HSP, moderate IgA reactivity was found against 4 of 12 microbial antigens. Immunoblot analysis demonstrated specific IgA and IgG responses against the endoproteinase Glu-C and the superantigens enterotoxin A and B of S. aureus, the IgA-protease of Neisseria gonorrhoeae, and Shiga toxin 2 of enterohemorrhagic E. coli. By using 3 different HSP batches in parallel, we could demonstrate antibody reactivity against important microbial pathogens and toxins. This antibody profile is essentially more homogeneous than that of 3 batches of FFP.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信