{"title":"Płock高架桥桥台混凝土透气性诊断","authors":"W. Kubissa, W. Dobaczewska","doi":"10.7409/RABDIM.021.010","DOIUrl":null,"url":null,"abstract":"The durability of reinforced concrete engineering structures is related to the resistance of the reinforcement cover to the penetration of aggressive liquid and gaseous media. According to Eurocode recommendations, the cover thickness should be adapted to the aggressiveness of the environment. Attempts are being made to use measurements of air perme- ability of concrete to assess the concrete integrity in the cover layer in order to detect possible imperfections in workmanship. The paper presents the results of air permeability test using the Torrent method carried out on the abutments of the road viaduct built in Plock. The abutments were made of air-entrained concrete of strength class C35/45, designed for exposure classes XC4, XD3, XF2. The air permeability test was carried out in accordance with Swiss standard SIA 262/1 to verify the quality of concrete in the structure. Air permeability measurements were also made on moulded control specimens for comparison. The usefulness of the method allowing for non-destructive verification of the cover layer uniformity in reinforced concrete structures was demonstrated.","PeriodicalId":44000,"journal":{"name":"Roads and Bridges-Drogi i Mosty","volume":"17 1","pages":"157-171"},"PeriodicalIF":0.5000,"publicationDate":"2021-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostics of air permeability of concrete in abutments of the viaduct in Płock\",\"authors\":\"W. Kubissa, W. Dobaczewska\",\"doi\":\"10.7409/RABDIM.021.010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The durability of reinforced concrete engineering structures is related to the resistance of the reinforcement cover to the penetration of aggressive liquid and gaseous media. According to Eurocode recommendations, the cover thickness should be adapted to the aggressiveness of the environment. Attempts are being made to use measurements of air perme- ability of concrete to assess the concrete integrity in the cover layer in order to detect possible imperfections in workmanship. The paper presents the results of air permeability test using the Torrent method carried out on the abutments of the road viaduct built in Plock. The abutments were made of air-entrained concrete of strength class C35/45, designed for exposure classes XC4, XD3, XF2. The air permeability test was carried out in accordance with Swiss standard SIA 262/1 to verify the quality of concrete in the structure. Air permeability measurements were also made on moulded control specimens for comparison. The usefulness of the method allowing for non-destructive verification of the cover layer uniformity in reinforced concrete structures was demonstrated.\",\"PeriodicalId\":44000,\"journal\":{\"name\":\"Roads and Bridges-Drogi i Mosty\",\"volume\":\"17 1\",\"pages\":\"157-171\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2021-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Roads and Bridges-Drogi i Mosty\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7409/RABDIM.021.010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Roads and Bridges-Drogi i Mosty","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7409/RABDIM.021.010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Diagnostics of air permeability of concrete in abutments of the viaduct in Płock
The durability of reinforced concrete engineering structures is related to the resistance of the reinforcement cover to the penetration of aggressive liquid and gaseous media. According to Eurocode recommendations, the cover thickness should be adapted to the aggressiveness of the environment. Attempts are being made to use measurements of air perme- ability of concrete to assess the concrete integrity in the cover layer in order to detect possible imperfections in workmanship. The paper presents the results of air permeability test using the Torrent method carried out on the abutments of the road viaduct built in Plock. The abutments were made of air-entrained concrete of strength class C35/45, designed for exposure classes XC4, XD3, XF2. The air permeability test was carried out in accordance with Swiss standard SIA 262/1 to verify the quality of concrete in the structure. Air permeability measurements were also made on moulded control specimens for comparison. The usefulness of the method allowing for non-destructive verification of the cover layer uniformity in reinforced concrete structures was demonstrated.
期刊介绍:
The quarterly journal Roads and Bridges – Drogi i Mosty is published by the Road and Bridge Research Institute since September 2012 as a bilingual English-Polish journal. From 2002 to 2012 the journal was printed under the title Drogi i Mosty. The journal mission is to promote current achievements in science and technology in the field of road and bridge engineering. The journal is intended as a forum of the exchange of innovative concepts and solutions between the researches from different countries. Original scientific and technical papers in the field of civil engineering and related engineering sciences are published. The scope of Roads and Bridges – Drogi i Mosty includes design, construction, maintenance and safe use of roads, bridges, airports and other transportation structures.