x射线小角散射线光栅的尺寸控制:形状和粗糙度提取

J. Reche, Y. Blancquaert, G. Freychet, P. Gergaud, M. Besacier
{"title":"x射线小角散射线光栅的尺寸控制:形状和粗糙度提取","authors":"J. Reche, Y. Blancquaert, G. Freychet, P. Gergaud, M. Besacier","doi":"10.1109/ASMC49169.2020.9185351","DOIUrl":null,"url":null,"abstract":"The capabilities of Small Angle X-ray Scattering (SAXS) for dimensional control of line gratings are reviewed. We first introduce different experimental methodologies used to extract the pitch, the critical dimension (CD) and the side-wall angle (SWA) of line gratings. A special focus is done on line roughness extraction. We already demonstrated that the SAXS technique has the sensitivity to measure line roughness amplitude below 1 nm on a set of line gratings designed with a controlled line roughness [1]. Fast Fourier Transforms (FFT) simulations revealed that the Line Width Roughness (LWR) defined as a Power Spectral Density (PSD) can be measured in a SAXS pattern at some specific positions in the reciprocal space [2]. In the present study, a comparison of the LWR PSD extracted by SAXS and by Scanning Electron Microscope (SEM) on one set of samples was done.","PeriodicalId":6771,"journal":{"name":"2020 31st Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)","volume":"44 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Dimensional Control of Line Gratings by Small Angle X-Ray Scattering: Shape and Roughness Extraction\",\"authors\":\"J. Reche, Y. Blancquaert, G. Freychet, P. Gergaud, M. Besacier\",\"doi\":\"10.1109/ASMC49169.2020.9185351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The capabilities of Small Angle X-ray Scattering (SAXS) for dimensional control of line gratings are reviewed. We first introduce different experimental methodologies used to extract the pitch, the critical dimension (CD) and the side-wall angle (SWA) of line gratings. A special focus is done on line roughness extraction. We already demonstrated that the SAXS technique has the sensitivity to measure line roughness amplitude below 1 nm on a set of line gratings designed with a controlled line roughness [1]. Fast Fourier Transforms (FFT) simulations revealed that the Line Width Roughness (LWR) defined as a Power Spectral Density (PSD) can be measured in a SAXS pattern at some specific positions in the reciprocal space [2]. In the present study, a comparison of the LWR PSD extracted by SAXS and by Scanning Electron Microscope (SEM) on one set of samples was done.\",\"PeriodicalId\":6771,\"journal\":{\"name\":\"2020 31st Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)\",\"volume\":\"44 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 31st Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASMC49169.2020.9185351\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 31st Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASMC49169.2020.9185351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

综述了小角x射线散射(SAXS)在线光栅尺寸控制中的作用。本文首先介绍了用于提取线光栅的节距、临界尺寸(CD)和侧壁角(SWA)的不同实验方法。特别关注了线条粗糙度的提取。我们已经证明,SAXS技术具有在一组线光栅上测量1 nm以下的线粗糙度振幅的灵敏度,该光栅设计了一个受控的线粗糙度[1]。快速傅里叶变换(FFT)模拟表明,定义为功率谱密度(PSD)的线宽粗糙度(LWR)可以在倒数空间[2]的某些特定位置以SAXS模式测量。本研究比较了SAXS法和扫描电镜法在同一样品上提取的LWR PSD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dimensional Control of Line Gratings by Small Angle X-Ray Scattering: Shape and Roughness Extraction
The capabilities of Small Angle X-ray Scattering (SAXS) for dimensional control of line gratings are reviewed. We first introduce different experimental methodologies used to extract the pitch, the critical dimension (CD) and the side-wall angle (SWA) of line gratings. A special focus is done on line roughness extraction. We already demonstrated that the SAXS technique has the sensitivity to measure line roughness amplitude below 1 nm on a set of line gratings designed with a controlled line roughness [1]. Fast Fourier Transforms (FFT) simulations revealed that the Line Width Roughness (LWR) defined as a Power Spectral Density (PSD) can be measured in a SAXS pattern at some specific positions in the reciprocal space [2]. In the present study, a comparison of the LWR PSD extracted by SAXS and by Scanning Electron Microscope (SEM) on one set of samples was done.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信