{"title":"一种简单的水下辐照度计的设计","authors":"T.H. Moller, H. Bailey","doi":"10.1016/S0302-3524(80)80088-0","DOIUrl":null,"url":null,"abstract":"<div><p>A description is given of the assembly, calibration and performance of an irradiance meter intended for underwater measurements in a single wave-band. The meter features high sensitivity by utilizing CdS photoconductors and a FET-type ohm meter, giving a linear response from 10<sup>−1</sup>–10<sup>−6</sup> W m<sup>−2</sup>. Instrument performance is discussed in relation to angular light response, immersion effect, response time, temperature dependence and filter bandwidth error.</p></div>","PeriodicalId":100492,"journal":{"name":"Estuarine and Coastal Marine Science","volume":"11 3","pages":"Pages 347-352"},"PeriodicalIF":0.0000,"publicationDate":"1980-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0302-3524(80)80088-0","citationCount":"2","resultStr":"{\"title\":\"A design for a simple underwater irradiance meter\",\"authors\":\"T.H. Moller, H. Bailey\",\"doi\":\"10.1016/S0302-3524(80)80088-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A description is given of the assembly, calibration and performance of an irradiance meter intended for underwater measurements in a single wave-band. The meter features high sensitivity by utilizing CdS photoconductors and a FET-type ohm meter, giving a linear response from 10<sup>−1</sup>–10<sup>−6</sup> W m<sup>−2</sup>. Instrument performance is discussed in relation to angular light response, immersion effect, response time, temperature dependence and filter bandwidth error.</p></div>\",\"PeriodicalId\":100492,\"journal\":{\"name\":\"Estuarine and Coastal Marine Science\",\"volume\":\"11 3\",\"pages\":\"Pages 347-352\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0302-3524(80)80088-0\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Estuarine and Coastal Marine Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0302352480800880\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Estuarine and Coastal Marine Science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0302352480800880","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
介绍了一种用于单波段水下测量的辐照度计的组装、校准和性能。该仪表采用CdS光导体和fet型欧姆计,具有高灵敏度,线性响应范围为10−1-10−6 W m−2。讨论了仪器性能与角光响应、浸入效应、响应时间、温度依赖性和滤波器带宽误差的关系。
A description is given of the assembly, calibration and performance of an irradiance meter intended for underwater measurements in a single wave-band. The meter features high sensitivity by utilizing CdS photoconductors and a FET-type ohm meter, giving a linear response from 10−1–10−6 W m−2. Instrument performance is discussed in relation to angular light response, immersion effect, response time, temperature dependence and filter bandwidth error.