血管内外周动脉瘤修复中自膨胀支架的变形。

M. E. Sitsen, G. Ho, J. Blankensteijn
{"title":"血管内外周动脉瘤修复中自膨胀支架的变形。","authors":"M. E. Sitsen, G. Ho, J. Blankensteijn","doi":"10.1177/152660289900600313","DOIUrl":null,"url":null,"abstract":"PURPOSE\nTo demonstrate the deformation of self-expandable stents after endovascular repair of peripheral aneurysms.\n\n\nMETHODS AND RESULTS\nThe Corvita Endoluminal Graft was used to treat a traumatic false aneurysm of the right subclavian artery and a common iliac artery aneurysm in 2 patients. In the subclavian case, the stent-graft showed a \"cigar-shaped\" deformation with hemodynamically significant stenoses at the proximal and distal ends at 3 months. In the second case, the same type of deformity was noted only 1 day after implantation. Two months later, the stent-graft occluded, necessitating surgical repair.\n\n\nCONCLUSIONS\nBoth cases demonstrate the possibility of stent deformation of self-expanding stent-grafts implanted at arterial sites not subject to external compression.","PeriodicalId":79443,"journal":{"name":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","volume":"27 1","pages":"288-92"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Deformation of self-expanding stent-grafts complicating endovascular peripheral aneurysm repair.\",\"authors\":\"M. E. Sitsen, G. Ho, J. Blankensteijn\",\"doi\":\"10.1177/152660289900600313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE\\nTo demonstrate the deformation of self-expandable stents after endovascular repair of peripheral aneurysms.\\n\\n\\nMETHODS AND RESULTS\\nThe Corvita Endoluminal Graft was used to treat a traumatic false aneurysm of the right subclavian artery and a common iliac artery aneurysm in 2 patients. In the subclavian case, the stent-graft showed a \\\"cigar-shaped\\\" deformation with hemodynamically significant stenoses at the proximal and distal ends at 3 months. In the second case, the same type of deformity was noted only 1 day after implantation. Two months later, the stent-graft occluded, necessitating surgical repair.\\n\\n\\nCONCLUSIONS\\nBoth cases demonstrate the possibility of stent deformation of self-expanding stent-grafts implanted at arterial sites not subject to external compression.\",\"PeriodicalId\":79443,\"journal\":{\"name\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"volume\":\"27 1\",\"pages\":\"288-92\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/152660289900600313\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/152660289900600313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

目的观察血管内修复周围动脉瘤后自膨胀支架的变形情况。方法与结果采用Corvita腔内移植物治疗2例外伤性右锁骨下动脉假性动脉瘤和髂总动脉瘤。在锁骨下病例中,支架移植物在3个月时出现“雪茄形”变形,并在近端和远端出现血流动力学上明显的狭窄。在第二个病例中,同一类型的畸形在植入后仅1天就出现了。两个月后,支架闭塞,需要手术修复。结论这两例病例均表明,在动脉部位不受外压的情况下,自膨胀支架植入有支架变形的可能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Deformation of self-expanding stent-grafts complicating endovascular peripheral aneurysm repair.
PURPOSE To demonstrate the deformation of self-expandable stents after endovascular repair of peripheral aneurysms. METHODS AND RESULTS The Corvita Endoluminal Graft was used to treat a traumatic false aneurysm of the right subclavian artery and a common iliac artery aneurysm in 2 patients. In the subclavian case, the stent-graft showed a "cigar-shaped" deformation with hemodynamically significant stenoses at the proximal and distal ends at 3 months. In the second case, the same type of deformity was noted only 1 day after implantation. Two months later, the stent-graft occluded, necessitating surgical repair. CONCLUSIONS Both cases demonstrate the possibility of stent deformation of self-expanding stent-grafts implanted at arterial sites not subject to external compression.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信