并网和离网光伏系统潮流控制

Zakaria Abousserhane, A. Abbou, Lahoucine Id-Khajine, N. Zakzouk
{"title":"并网和离网光伏系统潮流控制","authors":"Zakaria Abousserhane, A. Abbou, Lahoucine Id-Khajine, N. Zakzouk","doi":"10.1109/IRSEC48032.2019.9078274","DOIUrl":null,"url":null,"abstract":"This paper presents a PV system featuring two grid modes; on and standalone (off) mode. The main purpose of this work is verifying the effectiveness and feasibility of the power flow management strategy of the proposed system to fulfill the connected load demand with best utilization of considered sources, analyze the PV system performance under different grid modes. In case of normal grid conditions (mode ON), the PV system is connected to a three-phase grid and AC load. It supplies the load and grid in case of excess of PV power, and shares the peak load demands between grid and PV system. In case of grid faults, PV switches to off-grid mode, which it supplies the connected load and battery bank. The latter can store excess PV power or supplies the load in case of low or zero irradiances. The considered system tested using MATLAB/ Simulink.","PeriodicalId":6671,"journal":{"name":"2019 7th International Renewable and Sustainable Energy Conference (IRSEC)","volume":"36 1","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Power Flow Control of PV System Featuring On-Grid and Off-Grid Modes\",\"authors\":\"Zakaria Abousserhane, A. Abbou, Lahoucine Id-Khajine, N. Zakzouk\",\"doi\":\"10.1109/IRSEC48032.2019.9078274\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a PV system featuring two grid modes; on and standalone (off) mode. The main purpose of this work is verifying the effectiveness and feasibility of the power flow management strategy of the proposed system to fulfill the connected load demand with best utilization of considered sources, analyze the PV system performance under different grid modes. In case of normal grid conditions (mode ON), the PV system is connected to a three-phase grid and AC load. It supplies the load and grid in case of excess of PV power, and shares the peak load demands between grid and PV system. In case of grid faults, PV switches to off-grid mode, which it supplies the connected load and battery bank. The latter can store excess PV power or supplies the load in case of low or zero irradiances. The considered system tested using MATLAB/ Simulink.\",\"PeriodicalId\":6671,\"journal\":{\"name\":\"2019 7th International Renewable and Sustainable Energy Conference (IRSEC)\",\"volume\":\"36 1\",\"pages\":\"1-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 7th International Renewable and Sustainable Energy Conference (IRSEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IRSEC48032.2019.9078274\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 7th International Renewable and Sustainable Energy Conference (IRSEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRSEC48032.2019.9078274","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种具有两种电网模式的光伏发电系统;打开和独立(关闭)模式。本工作的主要目的是验证所提出的系统潮流管理策略的有效性和可行性,以最大限度地利用所考虑的资源来满足并网负荷需求,并分析不同电网模式下光伏系统的性能。在正常电网条件下(ON模式),光伏系统连接到三相电网和交流负载。在光伏发电电量过剩时,对负荷和电网进行供电,并在电网和光伏系统之间分担高峰负荷需求。当电网出现故障时,光伏发电切换到离网模式,向并网负载和蓄电池组供电。后者可以存储多余的光伏发电或在低辐照度或零辐照度的情况下提供负载。采用MATLAB/ Simulink对系统进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power Flow Control of PV System Featuring On-Grid and Off-Grid Modes
This paper presents a PV system featuring two grid modes; on and standalone (off) mode. The main purpose of this work is verifying the effectiveness and feasibility of the power flow management strategy of the proposed system to fulfill the connected load demand with best utilization of considered sources, analyze the PV system performance under different grid modes. In case of normal grid conditions (mode ON), the PV system is connected to a three-phase grid and AC load. It supplies the load and grid in case of excess of PV power, and shares the peak load demands between grid and PV system. In case of grid faults, PV switches to off-grid mode, which it supplies the connected load and battery bank. The latter can store excess PV power or supplies the load in case of low or zero irradiances. The considered system tested using MATLAB/ Simulink.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信