{"title":"分布式发电集成,增强电力系统保护","authors":"Ramini Hareesh, C. Pramod","doi":"10.1109/TAPENERGY.2015.7229637","DOIUrl":null,"url":null,"abstract":"Distributed Generation (DG) has increased tremendously from last two decades because of its advantages like production of highly reliable power by utilizing the renewable resources. But due to the integration of DG, power quality issues and power system protection problems arise. Fuse Recloser miscoordination is one of the problem which occurs due to the integration of DG with the grid. This paper presents a control with which fuse recloser coordination will not fail and loadis shared between the DGs according to their rating. To validate the same, simulations have been done in MATLAB/Simulink. Load sharing between the DGs has been simulated with the help of fuzzy controller for more precise control.","PeriodicalId":6552,"journal":{"name":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","volume":"34 1","pages":"310-315"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Distributed Generation integration with enhanced power system protection\",\"authors\":\"Ramini Hareesh, C. Pramod\",\"doi\":\"10.1109/TAPENERGY.2015.7229637\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distributed Generation (DG) has increased tremendously from last two decades because of its advantages like production of highly reliable power by utilizing the renewable resources. But due to the integration of DG, power quality issues and power system protection problems arise. Fuse Recloser miscoordination is one of the problem which occurs due to the integration of DG with the grid. This paper presents a control with which fuse recloser coordination will not fail and loadis shared between the DGs according to their rating. To validate the same, simulations have been done in MATLAB/Simulink. Load sharing between the DGs has been simulated with the help of fuzzy controller for more precise control.\",\"PeriodicalId\":6552,\"journal\":{\"name\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"volume\":\"34 1\",\"pages\":\"310-315\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAPENERGY.2015.7229637\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAPENERGY.2015.7229637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Distributed Generation integration with enhanced power system protection
Distributed Generation (DG) has increased tremendously from last two decades because of its advantages like production of highly reliable power by utilizing the renewable resources. But due to the integration of DG, power quality issues and power system protection problems arise. Fuse Recloser miscoordination is one of the problem which occurs due to the integration of DG with the grid. This paper presents a control with which fuse recloser coordination will not fail and loadis shared between the DGs according to their rating. To validate the same, simulations have been done in MATLAB/Simulink. Load sharing between the DGs has been simulated with the help of fuzzy controller for more precise control.