{"title":"Confiabilidade interavaliadores e intra-avaliador do escoliômetro","authors":"Guilherme H. Bonagamba, Daniel M. Coelho, A. S. Oliveira","doi":"10.1590/S1413-35552010005000025","DOIUrl":null,"url":null,"abstract":"BACKGROUND: The scoliometer was developed to analyze the axial rotation of the trunk in patients with idiopathic scoliosis. However, there is controversy regarding the reliability of the measures obtained with this device. OBJECTIVES: To test the intra-rater and inter-rater reliability of the scoliometer in patients with scoliosis. METHODS: 24 volunteers of both sex with idiopathic scoliosis diagnostic (18±4 years-old) and curvatures with mean and standard deviation of 24.8±12.7o Cobb. The measurement procedure was accomplished in one day by two trained examiners. The palpation and determination of each spinal level was accomplished by just one examiner. Each examiner obtained one measure with the device for each vertebra from the thoracic and lumbar levels in each evaluation. For statistical analysis the measurements were divided by spinal levels into upper thorax, medium thorax, lower thorax and lumbar segments. The Intraclass Correlation Coefficient type 1,1 (ICC1,1) was used to determine the intra-rater reliability while the ICC3,1 was used to determine the inter-rater reliability. RESULTS: The observed intra-rater reliability values for the medium and lower thorax and lumbar segments of the subjects ranged from very good to excellent. The inter-rater reliability of the measures of axial trunk rotations was considered good to the upper thorax and excellent for the medium and lower thorax and lumbar spine. CONCLUSIONS: The scoliometer is a device that has intra-rater reliability estimates ranging from very good to excellent. The inter-rater reliability for the upper and low thorax and for the lumbar spine is relatively lower than the intra-rater values for the same spinal segments, even when the errors from palpation and positioning of the instrument were eliminated.","PeriodicalId":21195,"journal":{"name":"Revista Brasileira De Fisioterapia","volume":"27 1","pages":"432-438"},"PeriodicalIF":0.0000,"publicationDate":"2010-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"44","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira De Fisioterapia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S1413-35552010005000025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 44

摘要

背景:脊柱侧弯测量仪用于分析特发性脊柱侧凸患者躯干的轴向旋转。然而,对于使用该装置获得的测量结果的可靠性存在争议。目的:检验脊柱侧凸患者脊柱侧弯计的内部和内部可靠性。方法:诊断为特发性脊柱侧凸的男女24名,年龄18±4岁,曲率平均值和标准差为24.8±12.70 Cobb。测量过程由两名经过培训的检验员在一天内完成。每个脊柱水平的触诊和确定仅由一名检查人员完成。在每次评估中,每个检查者使用该装置对每个椎体从胸椎和腰椎水平获得一个测量值。为了进行统计分析,测量结果按脊柱水平分为上胸、中胸、下胸和腰椎节段。类内相关系数类型1,1 (ICC1,1)用于确定评分内信度,而ICC3,1用于确定评分间信度。结果:观察到的受试者中、下胸腰椎节段的评分内信度值从非常好到优秀不等。轴向躯干旋转测量的评分间可靠性被认为对上胸很好,对中、下胸和腰椎很好。结论:脊柱侧弯计是一种具有从非常好到优秀的内部可靠性评估的设备。即使排除触诊和器械定位的误差,上、下胸和腰椎的评分间信度相对低于同一脊柱节段的评分内值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Confiabilidade interavaliadores e intra-avaliador do escoliômetro
BACKGROUND: The scoliometer was developed to analyze the axial rotation of the trunk in patients with idiopathic scoliosis. However, there is controversy regarding the reliability of the measures obtained with this device. OBJECTIVES: To test the intra-rater and inter-rater reliability of the scoliometer in patients with scoliosis. METHODS: 24 volunteers of both sex with idiopathic scoliosis diagnostic (18±4 years-old) and curvatures with mean and standard deviation of 24.8±12.7o Cobb. The measurement procedure was accomplished in one day by two trained examiners. The palpation and determination of each spinal level was accomplished by just one examiner. Each examiner obtained one measure with the device for each vertebra from the thoracic and lumbar levels in each evaluation. For statistical analysis the measurements were divided by spinal levels into upper thorax, medium thorax, lower thorax and lumbar segments. The Intraclass Correlation Coefficient type 1,1 (ICC1,1) was used to determine the intra-rater reliability while the ICC3,1 was used to determine the inter-rater reliability. RESULTS: The observed intra-rater reliability values for the medium and lower thorax and lumbar segments of the subjects ranged from very good to excellent. The inter-rater reliability of the measures of axial trunk rotations was considered good to the upper thorax and excellent for the medium and lower thorax and lumbar spine. CONCLUSIONS: The scoliometer is a device that has intra-rater reliability estimates ranging from very good to excellent. The inter-rater reliability for the upper and low thorax and for the lumbar spine is relatively lower than the intra-rater values for the same spinal segments, even when the errors from palpation and positioning of the instrument were eliminated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信