航空航天钛合金熔模铸件的x射线计算机断层扫描

Anton du Plessis , Pierre Rossouw
{"title":"航空航天钛合金熔模铸件的x射线计算机断层扫描","authors":"Anton du Plessis ,&nbsp;Pierre Rossouw","doi":"10.1016/j.csndt.2015.03.001","DOIUrl":null,"url":null,"abstract":"<div><p>This case study demonstrates the type of non-destructive analysis possible using X-ray micro computed tomography (microCT) for a titanium aerospace investment casting of 225 mm in its longest axis. The advantages of the method are highlighted while the limitations are also discussed. Recently the method has become more accessible and affordable due to multi-user service facilities and the analysis has become simpler due to software and hardware improvements. This case study demonstrates a typical analysis including defect detection, wall thickness and part to CAD comparison, which can be done in less than 4 h, while simpler results are possible in under 1 h. This will be particularly useful for industries requiring quick but detailed non-destructive analysis.</p></div>","PeriodicalId":100221,"journal":{"name":"Case Studies in Nondestructive Testing and Evaluation","volume":"3 ","pages":"Pages 21-26"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.csndt.2015.03.001","citationCount":"42","resultStr":"{\"title\":\"X-ray computed tomography of a titanium aerospace investment casting\",\"authors\":\"Anton du Plessis ,&nbsp;Pierre Rossouw\",\"doi\":\"10.1016/j.csndt.2015.03.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This case study demonstrates the type of non-destructive analysis possible using X-ray micro computed tomography (microCT) for a titanium aerospace investment casting of 225 mm in its longest axis. The advantages of the method are highlighted while the limitations are also discussed. Recently the method has become more accessible and affordable due to multi-user service facilities and the analysis has become simpler due to software and hardware improvements. This case study demonstrates a typical analysis including defect detection, wall thickness and part to CAD comparison, which can be done in less than 4 h, while simpler results are possible in under 1 h. This will be particularly useful for industries requiring quick but detailed non-destructive analysis.</p></div>\",\"PeriodicalId\":100221,\"journal\":{\"name\":\"Case Studies in Nondestructive Testing and Evaluation\",\"volume\":\"3 \",\"pages\":\"Pages 21-26\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.csndt.2015.03.001\",\"citationCount\":\"42\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Studies in Nondestructive Testing and Evaluation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214657115000040\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Studies in Nondestructive Testing and Evaluation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214657115000040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 42

摘要

本案例研究展示了使用x射线微计算机断层扫描(microCT)对最长轴为225毫米的钛航空航天熔模铸件进行非破坏性分析的可能性。强调了该方法的优点,同时也讨论了其局限性。最近,由于多用户服务设施,该方法变得更容易获得和负担得起,并且由于软件和硬件的改进,分析变得更简单。本案例研究展示了一个典型的分析,包括缺陷检测、壁厚和零件与CAD的比较,这可以在不到4小时内完成,而更简单的结果可能在1小时内完成。这对于需要快速但详细的非破坏性分析的行业特别有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
X-ray computed tomography of a titanium aerospace investment casting

This case study demonstrates the type of non-destructive analysis possible using X-ray micro computed tomography (microCT) for a titanium aerospace investment casting of 225 mm in its longest axis. The advantages of the method are highlighted while the limitations are also discussed. Recently the method has become more accessible and affordable due to multi-user service facilities and the analysis has become simpler due to software and hardware improvements. This case study demonstrates a typical analysis including defect detection, wall thickness and part to CAD comparison, which can be done in less than 4 h, while simpler results are possible in under 1 h. This will be particularly useful for industries requiring quick but detailed non-destructive analysis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信