石墨粉对钢筋混凝土的腐蚀作用及其物理电化学性能评价

A. Flores-Nicolás, M. Flores-Nicolás, J. Uruchurtu-Chavarín
{"title":"石墨粉对钢筋混凝土的腐蚀作用及其物理电化学性能评价","authors":"A. Flores-Nicolás, M. Flores-Nicolás, J. Uruchurtu-Chavarín","doi":"10.21041/ra.v11i1.501","DOIUrl":null,"url":null,"abstract":"The corrosion of reinforced concrete without and with the addition of graphite powder with low carbon content was evaluated. Phase identification processes and physical-electrochemical properties of the concrete were analyzed using X-ray diffraction techniques (XRD), scanning electron microscopy (SEM), half-cell potential, electrochemical noise (EN) and linear polarization resistance (LPR). Samples were studied for 168 days in saline solution. The results show that, when adding graphite powder in an amount of 2.5% by weight of cement, the compressive strength increased if compared with the control sample. The electrochemical tests show that the higher the level of graphite replacement, the higher the level of corrosion in concrete.","PeriodicalId":21260,"journal":{"name":"Revista ALCONPAT","volume":"77 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Corrosion effect on reinforced concrete with the addition of graphite powder and its evaluation on physical-electrochemical properties\",\"authors\":\"A. Flores-Nicolás, M. Flores-Nicolás, J. Uruchurtu-Chavarín\",\"doi\":\"10.21041/ra.v11i1.501\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The corrosion of reinforced concrete without and with the addition of graphite powder with low carbon content was evaluated. Phase identification processes and physical-electrochemical properties of the concrete were analyzed using X-ray diffraction techniques (XRD), scanning electron microscopy (SEM), half-cell potential, electrochemical noise (EN) and linear polarization resistance (LPR). Samples were studied for 168 days in saline solution. The results show that, when adding graphite powder in an amount of 2.5% by weight of cement, the compressive strength increased if compared with the control sample. The electrochemical tests show that the higher the level of graphite replacement, the higher the level of corrosion in concrete.\",\"PeriodicalId\":21260,\"journal\":{\"name\":\"Revista ALCONPAT\",\"volume\":\"77 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista ALCONPAT\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21041/ra.v11i1.501\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista ALCONPAT","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21041/ra.v11i1.501","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

研究了低碳石墨粉对钢筋混凝土的腐蚀性能。采用x射线衍射技术(XRD)、扫描电镜(SEM)、半电池电势、电化学噪声(EN)和线性极化电阻(LPR)分析了混凝土的物相识别过程和物理电化学性能。样品在盐水溶液中研究168天。结果表明,当石墨粉的掺量为水泥质量的2.5%时,其抗压强度较对照样品有所提高。电化学试验表明,石墨置换水平越高,混凝土腐蚀程度越高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Corrosion effect on reinforced concrete with the addition of graphite powder and its evaluation on physical-electrochemical properties
The corrosion of reinforced concrete without and with the addition of graphite powder with low carbon content was evaluated. Phase identification processes and physical-electrochemical properties of the concrete were analyzed using X-ray diffraction techniques (XRD), scanning electron microscopy (SEM), half-cell potential, electrochemical noise (EN) and linear polarization resistance (LPR). Samples were studied for 168 days in saline solution. The results show that, when adding graphite powder in an amount of 2.5% by weight of cement, the compressive strength increased if compared with the control sample. The electrochemical tests show that the higher the level of graphite replacement, the higher the level of corrosion in concrete.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信