{"title":"再治疗过程中对碎片根尖挤压的评价:R-Endo旋转器械与手锉","authors":"Nazan Yırgın Akgül, F. Haznedaroğlu, Çagla Vardar","doi":"10.5577/intdentres.2022.vol12.no2.6","DOIUrl":null,"url":null,"abstract":"Aim: The aim of this ex vivo study was to compare the amount of debris extruded during retreatment using stainless steel hand files (Hedstroem files) and R-Endo Nickel Titanium rotary instruments.\nMethodology: Eighty single-rooted freshly extracted human mandibular premolars were divided into two groups consisting of 40 teeth each. Retreatment was performed with R-Endo (Micro-Mega, Besançon, France) and Hedstroem files (Dentsply, Maillefer, Ballaigeus, Switzerland). The experimental teeth were obturated with lateral condensation technique. Then, 1.5-mL Eppendorf tubes were used to collecting the material that was extruded during preparation by subtracting post-instrumentation weight from pre-instrumentation weight.\nResults: There were significant differences in the amount of debris extruded between the groups (p<0.001). The amount of apical extrusion in the R-Endo group was determined to be less than in the hand instrumentation group.\nConclusion: Within the limitations of this study, it might be concluded that all tested instruments resulted in apical extrusion of debris. During endodontic retreatment procedures, the hand files extruded a significantly higher amount of debris than the R-Endo.\n \nHow to cite this article: \nYırgın Akgül N, Haznedaroğlu F, Vardar Ç. Evaluation of apical extrusion of debris during retreatment: R-Endo rotary instruments versus hand files. Int Dent Res 2022;12(2):82-7. https://doi.org/10.5577/intdentres.2022.vol12.no2.6\n \nLinguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.","PeriodicalId":31322,"journal":{"name":"Journal of International Clinical Dental Research Organization","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of apical extrusion of debris during retreatment: R-Endo rotary instruments versus hand files\",\"authors\":\"Nazan Yırgın Akgül, F. Haznedaroğlu, Çagla Vardar\",\"doi\":\"10.5577/intdentres.2022.vol12.no2.6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: The aim of this ex vivo study was to compare the amount of debris extruded during retreatment using stainless steel hand files (Hedstroem files) and R-Endo Nickel Titanium rotary instruments.\\nMethodology: Eighty single-rooted freshly extracted human mandibular premolars were divided into two groups consisting of 40 teeth each. Retreatment was performed with R-Endo (Micro-Mega, Besançon, France) and Hedstroem files (Dentsply, Maillefer, Ballaigeus, Switzerland). The experimental teeth were obturated with lateral condensation technique. Then, 1.5-mL Eppendorf tubes were used to collecting the material that was extruded during preparation by subtracting post-instrumentation weight from pre-instrumentation weight.\\nResults: There were significant differences in the amount of debris extruded between the groups (p<0.001). The amount of apical extrusion in the R-Endo group was determined to be less than in the hand instrumentation group.\\nConclusion: Within the limitations of this study, it might be concluded that all tested instruments resulted in apical extrusion of debris. During endodontic retreatment procedures, the hand files extruded a significantly higher amount of debris than the R-Endo.\\n \\nHow to cite this article: \\nYırgın Akgül N, Haznedaroğlu F, Vardar Ç. Evaluation of apical extrusion of debris during retreatment: R-Endo rotary instruments versus hand files. Int Dent Res 2022;12(2):82-7. https://doi.org/10.5577/intdentres.2022.vol12.no2.6\\n \\nLinguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.\",\"PeriodicalId\":31322,\"journal\":{\"name\":\"Journal of International Clinical Dental Research Organization\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of International Clinical Dental Research Organization\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5577/intdentres.2022.vol12.no2.6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of International Clinical Dental Research Organization","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5577/intdentres.2022.vol12.no2.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
目的:本离体研究的目的是比较使用不锈钢手锉(Hedstroem锉)和R-Endo镍钛旋转器械再处理时挤压出的碎片数量。方法:将80颗刚拔除的单根人下颌前磨牙分为两组,每组40颗。再治疗采用R-Endo (Micro-Mega, besanon,法国)和Hedstroem锉(Dentsply, Maillefer, Ballaigeus,瑞士)。采用侧缩技术对实验牙进行封闭。然后,用1.5 ml埃彭多夫管收集制备过程中挤出的材料,方法是用仪器前重量减去仪器后重量。结果:两组间挤出碎片量差异有统计学意义(p<0.001)。R-Endo组的根尖挤压量小于手部器械组。结论:在本研究的局限性内,可以得出结论,所有测试的器械都会导致碎片的根尖挤压。在根管再治疗过程中,手锉比R-Endo挤出更多的碎片。本文出处:Yırgın akg l N, Haznedaroğlu F, Vardar Ç。再治疗过程中对碎片根尖挤压的评价:R-Endo旋转器械与手锉。国际医学杂志,2016;12(2):82-7。https://doi.org/10.5577/intdentres.2022.vol12.no2.6语言修改:本手稿中的英语已由至少两名专业编辑检查,他们都是英语母语者。
Evaluation of apical extrusion of debris during retreatment: R-Endo rotary instruments versus hand files
Aim: The aim of this ex vivo study was to compare the amount of debris extruded during retreatment using stainless steel hand files (Hedstroem files) and R-Endo Nickel Titanium rotary instruments.
Methodology: Eighty single-rooted freshly extracted human mandibular premolars were divided into two groups consisting of 40 teeth each. Retreatment was performed with R-Endo (Micro-Mega, Besançon, France) and Hedstroem files (Dentsply, Maillefer, Ballaigeus, Switzerland). The experimental teeth were obturated with lateral condensation technique. Then, 1.5-mL Eppendorf tubes were used to collecting the material that was extruded during preparation by subtracting post-instrumentation weight from pre-instrumentation weight.
Results: There were significant differences in the amount of debris extruded between the groups (p<0.001). The amount of apical extrusion in the R-Endo group was determined to be less than in the hand instrumentation group.
Conclusion: Within the limitations of this study, it might be concluded that all tested instruments resulted in apical extrusion of debris. During endodontic retreatment procedures, the hand files extruded a significantly higher amount of debris than the R-Endo.
How to cite this article:
Yırgın Akgül N, Haznedaroğlu F, Vardar Ç. Evaluation of apical extrusion of debris during retreatment: R-Endo rotary instruments versus hand files. Int Dent Res 2022;12(2):82-7. https://doi.org/10.5577/intdentres.2022.vol12.no2.6
Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.