超声辅助-分散-离子液-液微萃取法提取镉的新型配体-(4-溴苄氧基)苯甲醛硫代氨基脲(MBBOTSC)的合成与鉴定

A. Hassanzadeh, B. Amirheidari, Ahmad Salarifar, A. Asadipour, Yaghoub Pourshojaei
{"title":"超声辅助-分散-离子液-液微萃取法提取镉的新型配体-(4-溴苄氧基)苯甲醛硫代氨基脲(MBBOTSC)的合成与鉴定","authors":"A. Hassanzadeh, B. Amirheidari, Ahmad Salarifar, A. Asadipour, Yaghoub Pourshojaei","doi":"10.24200/amecj.v4.i04.161","DOIUrl":null,"url":null,"abstract":"In this research, meta-(4-bromobenzyloxy) benzaldehyde thiosemicarbazone (MBBOTSC) as a novel ligand was synthesized from the reaction between meta-(4-bromobenzyloxy) benzaldehyde and thiosemicarbazide under basic condition in water and ethanol as solvents. Ligand has the ability to chelate ions and therefore, it was used to form a complex and extract ions. Then, the cadmium ions in water and wastewater samples were separated based on MBBOTSC by ultrasound assisted-dispersive-ionic liquid-liquid microextraction method (USA-D-ILLME) before determination by AT-F-AAS. The MBBOTSC ligand was added to the mixture of the ionic liquid/acetone (IL/AC, [OMIM][PF6]) and then injected by syringe to 50 mL of water samples at pH 6-7. The sample was put into the ultrasonic accessory for 5 minutes, after complexation (Ligand-Cd; RS…Cd….RS), the water sample was centrifuged for 3 min for phase separation.  Due to complexation and back-extraction of Cd in liquid phase, the amount of Cd ions in the water samples was determined by AT-F-AAS . In optimized conditions, the Linear ranges and LOD for 50 mL of water samples were obtained 1-36 μg L-1 and 0.3 μg L-1, respectively (Mean RSD= 1.26%). The validation results were successfully achieved by spiking real samples and using ET-AAS.","PeriodicalId":7797,"journal":{"name":"Analytical Methods in Environmental Chemistry Journal","volume":"4 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Synthesis and identification of meta-(4-bromobenzyloxy) benzaldehyde thiosemicarbazone (MBBOTSC) as novel ligand for cadmium extraction by ultrasound assisted-dispersive-ionic liquid-liquid micro extraction method\",\"authors\":\"A. Hassanzadeh, B. Amirheidari, Ahmad Salarifar, A. Asadipour, Yaghoub Pourshojaei\",\"doi\":\"10.24200/amecj.v4.i04.161\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this research, meta-(4-bromobenzyloxy) benzaldehyde thiosemicarbazone (MBBOTSC) as a novel ligand was synthesized from the reaction between meta-(4-bromobenzyloxy) benzaldehyde and thiosemicarbazide under basic condition in water and ethanol as solvents. Ligand has the ability to chelate ions and therefore, it was used to form a complex and extract ions. Then, the cadmium ions in water and wastewater samples were separated based on MBBOTSC by ultrasound assisted-dispersive-ionic liquid-liquid microextraction method (USA-D-ILLME) before determination by AT-F-AAS. The MBBOTSC ligand was added to the mixture of the ionic liquid/acetone (IL/AC, [OMIM][PF6]) and then injected by syringe to 50 mL of water samples at pH 6-7. The sample was put into the ultrasonic accessory for 5 minutes, after complexation (Ligand-Cd; RS…Cd….RS), the water sample was centrifuged for 3 min for phase separation.  Due to complexation and back-extraction of Cd in liquid phase, the amount of Cd ions in the water samples was determined by AT-F-AAS . In optimized conditions, the Linear ranges and LOD for 50 mL of water samples were obtained 1-36 μg L-1 and 0.3 μg L-1, respectively (Mean RSD= 1.26%). The validation results were successfully achieved by spiking real samples and using ET-AAS.\",\"PeriodicalId\":7797,\"journal\":{\"name\":\"Analytical Methods in Environmental Chemistry Journal\",\"volume\":\"4 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Methods in Environmental Chemistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24200/amecj.v4.i04.161\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods in Environmental Chemistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24200/amecj.v4.i04.161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究以间(4-溴苄氧基)苯甲醛和硫代氨基脲为原料,在水和乙醇为溶剂的碱性条件下合成了间(4-溴苄氧基)苯甲醛硫代氨基脲(MBBOTSC)作为一种新型配体。配体具有螯合离子的能力,因此,它被用来形成络合物和提取离子。然后,采用超声辅助分散离子液-液微萃取法(USA-D-ILLME)对MBBOTSC水溶液和废水样品中的镉离子进行分离,并用AT-F-AAS法进行测定。将MBBOTSC配体加入到离子液体/丙酮混合物(IL/AC, [OMIM][PF6])中,然后在pH 6-7的条件下,用注射器注射到50 mL的水样中。将样品置于超声附件中5分钟,络合(配体- cd;RS…Cd....RS),水样离心3min进行相分离。由于Cd在液相中的络合作用和反萃取作用,采用AT-F-AAS法测定了水样中Cd离子的含量。优化条件下,50 mL水样的检出限分别为0.3 μg L-1和1 ~ 36 μg L-1(平均RSD= 1.26%)。通过对实际样品进行峰化和ET-AAS验证,验证结果得到了满意的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Synthesis and identification of meta-(4-bromobenzyloxy) benzaldehyde thiosemicarbazone (MBBOTSC) as novel ligand for cadmium extraction by ultrasound assisted-dispersive-ionic liquid-liquid micro extraction method
In this research, meta-(4-bromobenzyloxy) benzaldehyde thiosemicarbazone (MBBOTSC) as a novel ligand was synthesized from the reaction between meta-(4-bromobenzyloxy) benzaldehyde and thiosemicarbazide under basic condition in water and ethanol as solvents. Ligand has the ability to chelate ions and therefore, it was used to form a complex and extract ions. Then, the cadmium ions in water and wastewater samples were separated based on MBBOTSC by ultrasound assisted-dispersive-ionic liquid-liquid microextraction method (USA-D-ILLME) before determination by AT-F-AAS. The MBBOTSC ligand was added to the mixture of the ionic liquid/acetone (IL/AC, [OMIM][PF6]) and then injected by syringe to 50 mL of water samples at pH 6-7. The sample was put into the ultrasonic accessory for 5 minutes, after complexation (Ligand-Cd; RS…Cd….RS), the water sample was centrifuged for 3 min for phase separation.  Due to complexation and back-extraction of Cd in liquid phase, the amount of Cd ions in the water samples was determined by AT-F-AAS . In optimized conditions, the Linear ranges and LOD for 50 mL of water samples were obtained 1-36 μg L-1 and 0.3 μg L-1, respectively (Mean RSD= 1.26%). The validation results were successfully achieved by spiking real samples and using ET-AAS.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信