频率估计驱动的自适应瞬时过流:一个使用巴西实际系统的案例研究

C. Souza, H. Sanca, F. Costa, B. A. Souza
{"title":"频率估计驱动的自适应瞬时过流:一个使用巴西实际系统的案例研究","authors":"C. Souza, H. Sanca, F. Costa, B. A. Souza","doi":"10.1109/TDC.2016.7520033","DOIUrl":null,"url":null,"abstract":"With increasing of distributed generation (DG) and smart grid applications, power protection system (PPS) have been passing for several challenges. Traditional relay coordination presents a relevant difficult to operate with DG plants. Modifications on short-circuits levels and current directionality may include miscoordinations on PPS. An alternative of traditional relay system is adaptive protective system (APS). APS provides an automatic update of relay setting ever when power grid have a modification. A large number of method may be used to identify these modification. In this paper a frequency estimation method was used to identify grid modification and flag to APS methods. To evaluate proposed method, a real Brazilian distribution system was used considering that only instantaneous overcurrent relay compose PPS. Obtainer results shown a efficacy on grid topology identification and same modification among obtained relay settings using APS architecture.","PeriodicalId":6497,"journal":{"name":"2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"68 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Adaptive Instantaneous Overcurrent Powered By Frequency Estimation: A case study using a real Brazilian system\",\"authors\":\"C. Souza, H. Sanca, F. Costa, B. A. Souza\",\"doi\":\"10.1109/TDC.2016.7520033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With increasing of distributed generation (DG) and smart grid applications, power protection system (PPS) have been passing for several challenges. Traditional relay coordination presents a relevant difficult to operate with DG plants. Modifications on short-circuits levels and current directionality may include miscoordinations on PPS. An alternative of traditional relay system is adaptive protective system (APS). APS provides an automatic update of relay setting ever when power grid have a modification. A large number of method may be used to identify these modification. In this paper a frequency estimation method was used to identify grid modification and flag to APS methods. To evaluate proposed method, a real Brazilian distribution system was used considering that only instantaneous overcurrent relay compose PPS. Obtainer results shown a efficacy on grid topology identification and same modification among obtained relay settings using APS architecture.\",\"PeriodicalId\":6497,\"journal\":{\"name\":\"2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)\",\"volume\":\"68 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDC.2016.7520033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2016.7520033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

随着分布式发电(DG)和智能电网应用的不断增加,电力保护系统(PPS)面临着诸多挑战。传统的继电器协调存在与DG电厂相关的操作困难。对短路电平和电流方向的修改可能包括PPS上的不协调。自适应保护系统是传统继电保护系统的一种替代方案。当电网发生变化时,APS可自动更新继电器设置。可以使用大量的方法来识别这些修改。本文采用频率估计方法识别网格修改,并将其标记为APS方法。为了验证所提出的方法,以一个实际的巴西配电系统为例,考虑了瞬时过流继电器构成PPS。获取器的结果表明,使用APS架构可以有效地识别网格拓扑,并在获得的中继设置之间进行相同的修改。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adaptive Instantaneous Overcurrent Powered By Frequency Estimation: A case study using a real Brazilian system
With increasing of distributed generation (DG) and smart grid applications, power protection system (PPS) have been passing for several challenges. Traditional relay coordination presents a relevant difficult to operate with DG plants. Modifications on short-circuits levels and current directionality may include miscoordinations on PPS. An alternative of traditional relay system is adaptive protective system (APS). APS provides an automatic update of relay setting ever when power grid have a modification. A large number of method may be used to identify these modification. In this paper a frequency estimation method was used to identify grid modification and flag to APS methods. To evaluate proposed method, a real Brazilian distribution system was used considering that only instantaneous overcurrent relay compose PPS. Obtainer results shown a efficacy on grid topology identification and same modification among obtained relay settings using APS architecture.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信