多次冲击电压老化油膜介质的时域介电响应研究

Chenmeng Zhang, Kailin Zhao, S. Xie, Can Hu, Yu Zhang, Nanxi Jiang
{"title":"多次冲击电压老化油膜介质的时域介电响应研究","authors":"Chenmeng Zhang, Kailin Zhao, S. Xie, Can Hu, Yu Zhang, Nanxi Jiang","doi":"10.1109/ICHVE49031.2020.9279656","DOIUrl":null,"url":null,"abstract":"Power capacitors suffer multiple impulse voltage during their lifetime. With the multiple impulse voltage aging, the insulation - oil-film dielectric, may deteriorate and even fail in the early stage. The time-domain dielectric response of oil-film dielectric with multiple impulse voltage aging is studied in this paper. At first, an aging and testing platform for oil film medium under impulse voltage was built to test the time-domain dielectric response (polarization depolarization current, PDC) of oil-film dielectric with multiple impulse voltage aging. And then, according to tested PDC, extended Debye model and characteristic parameters were obtained by matrix pencil algorithm identification. The results show that with the increase of impulse voltage times, the time-domain dielectric response of oil-film dielectric changes accordingly, as well as the branch parameters and characteristic parameters of the extended Debye model. At last, the test results are discussed.","PeriodicalId":6763,"journal":{"name":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","volume":"5 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Time-domain Dielectric Response of Multiple Impulse Voltage Aging Oil-film Dielectric\",\"authors\":\"Chenmeng Zhang, Kailin Zhao, S. Xie, Can Hu, Yu Zhang, Nanxi Jiang\",\"doi\":\"10.1109/ICHVE49031.2020.9279656\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power capacitors suffer multiple impulse voltage during their lifetime. With the multiple impulse voltage aging, the insulation - oil-film dielectric, may deteriorate and even fail in the early stage. The time-domain dielectric response of oil-film dielectric with multiple impulse voltage aging is studied in this paper. At first, an aging and testing platform for oil film medium under impulse voltage was built to test the time-domain dielectric response (polarization depolarization current, PDC) of oil-film dielectric with multiple impulse voltage aging. And then, according to tested PDC, extended Debye model and characteristic parameters were obtained by matrix pencil algorithm identification. The results show that with the increase of impulse voltage times, the time-domain dielectric response of oil-film dielectric changes accordingly, as well as the branch parameters and characteristic parameters of the extended Debye model. At last, the test results are discussed.\",\"PeriodicalId\":6763,\"journal\":{\"name\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"volume\":\"5 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE49031.2020.9279656\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE49031.2020.9279656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

功率电容器在使用寿命期间承受多次脉冲电压。随着多次冲击电压的老化,绝缘油膜介质可能出现劣化,甚至早期失效。研究了多重冲击电压老化时油膜介质的时域介电响应。首先,搭建了冲击电压下油膜介质老化测试平台,测试了多重冲击电压老化下油膜介质的时域介电响应(极化去极化电流,PDC)。然后,根据实测PDC,通过矩阵铅笔算法辨识得到扩展Debye模型和特征参数。结果表明,随着冲击电压次数的增加,油膜介质的时域介电响应以及扩展Debye模型的分支参数和特征参数都发生了相应的变化。最后对试验结果进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on Time-domain Dielectric Response of Multiple Impulse Voltage Aging Oil-film Dielectric
Power capacitors suffer multiple impulse voltage during their lifetime. With the multiple impulse voltage aging, the insulation - oil-film dielectric, may deteriorate and even fail in the early stage. The time-domain dielectric response of oil-film dielectric with multiple impulse voltage aging is studied in this paper. At first, an aging and testing platform for oil film medium under impulse voltage was built to test the time-domain dielectric response (polarization depolarization current, PDC) of oil-film dielectric with multiple impulse voltage aging. And then, according to tested PDC, extended Debye model and characteristic parameters were obtained by matrix pencil algorithm identification. The results show that with the increase of impulse voltage times, the time-domain dielectric response of oil-film dielectric changes accordingly, as well as the branch parameters and characteristic parameters of the extended Debye model. At last, the test results are discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信