差压变送器,与静压的跨度位移误差

Q3 Engineering
L. T. Akeley
{"title":"差压变送器,与静压的跨度位移误差","authors":"L. T. Akeley","doi":"10.1115/1.3425583","DOIUrl":null,"url":null,"abstract":"The author reviews methods of calibrating low-differential (25–300 in. H2 O) D.P. transmitters at high (up to 3000 psig) static pressure. Various test methods are described along with discussion of their merits. Included are use of one or more deadweight testers (gas or liquid) and use of a high-pressure mercury manometer as a standard. Five D.P. transmitters of different construction are tested and their static span-shift performance reported.","PeriodicalId":34897,"journal":{"name":"应用基础与工程科学学报","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1972-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Differential Pressure Transmitters, Span-Shift Errors With Static Pressure\",\"authors\":\"L. T. Akeley\",\"doi\":\"10.1115/1.3425583\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The author reviews methods of calibrating low-differential (25–300 in. H2 O) D.P. transmitters at high (up to 3000 psig) static pressure. Various test methods are described along with discussion of their merits. Included are use of one or more deadweight testers (gas or liquid) and use of a high-pressure mercury manometer as a standard. Five D.P. transmitters of different construction are tested and their static span-shift performance reported.\",\"PeriodicalId\":34897,\"journal\":{\"name\":\"应用基础与工程科学学报\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1972-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"应用基础与工程科学学报\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.1115/1.3425583\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"应用基础与工程科学学报","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.1115/1.3425583","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1

摘要

作者回顾了校准低差(25-300英寸)的方法。H2 O) dp变送器在高(高达3000 psig)静压下。描述了各种测试方法,并讨论了它们的优点。包括使用一个或多个自重测试仪(气体或液体)和使用高压水银压力计作为标准。对5种不同结构的dp发射机进行了测试,并报告了它们的静态跨移性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Differential Pressure Transmitters, Span-Shift Errors With Static Pressure
The author reviews methods of calibrating low-differential (25–300 in. H2 O) D.P. transmitters at high (up to 3000 psig) static pressure. Various test methods are described along with discussion of their merits. Included are use of one or more deadweight testers (gas or liquid) and use of a high-pressure mercury manometer as a standard. Five D.P. transmitters of different construction are tested and their static span-shift performance reported.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
应用基础与工程科学学报
应用基础与工程科学学报 Engineering-Engineering (all)
CiteScore
1.60
自引率
0.00%
发文量
2784
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信