{"title":"经胸骨上切迹测量线性心输出量的连续波多普勒换能器优化问题","authors":"P. Tsiganos, A. Fairhead","doi":"10.1109/ULTSYM.1997.661811","DOIUrl":null,"url":null,"abstract":"In this work the authors address some of the problems associated with the optimization of CW transducers to be used via the suprasternal notch window (SSN) to insonate the aortic arch. Firstly, the geometrical characteristics of the anatomical region of interest are evaluated. Secondly, based on these characteristics, the required interrogation field (RIF) is defined and used as a criterion for classifying the suitability of any probe used in this application. Thirdly, the interrogation fields of two commercial probes are evaluated based on this criterion. Finally, a design methodology is proposed and implemented for defining a source and receiver distribution that produces an interrogation field with improved coverage of the RIF.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":"155 1","pages":"1277-1280 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the problem of CW Doppler transducer optimization for linear cardiac output measurement via the suprasternal notch\",\"authors\":\"P. Tsiganos, A. Fairhead\",\"doi\":\"10.1109/ULTSYM.1997.661811\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work the authors address some of the problems associated with the optimization of CW transducers to be used via the suprasternal notch window (SSN) to insonate the aortic arch. Firstly, the geometrical characteristics of the anatomical region of interest are evaluated. Secondly, based on these characteristics, the required interrogation field (RIF) is defined and used as a criterion for classifying the suitability of any probe used in this application. Thirdly, the interrogation fields of two commercial probes are evaluated based on this criterion. Finally, a design methodology is proposed and implemented for defining a source and receiver distribution that produces an interrogation field with improved coverage of the RIF.\",\"PeriodicalId\":6369,\"journal\":{\"name\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"volume\":\"155 1\",\"pages\":\"1277-1280 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1997.661811\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.661811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On the problem of CW Doppler transducer optimization for linear cardiac output measurement via the suprasternal notch
In this work the authors address some of the problems associated with the optimization of CW transducers to be used via the suprasternal notch window (SSN) to insonate the aortic arch. Firstly, the geometrical characteristics of the anatomical region of interest are evaluated. Secondly, based on these characteristics, the required interrogation field (RIF) is defined and used as a criterion for classifying the suitability of any probe used in this application. Thirdly, the interrogation fields of two commercial probes are evaluated based on this criterion. Finally, a design methodology is proposed and implemented for defining a source and receiver distribution that produces an interrogation field with improved coverage of the RIF.