CDX-U环形液体锂限流器

IF 0.3 1区 艺术学 0 MUSIC
R. Majeski, G. Antar, M. Boaz, D. Buchenauer, L. Cadwallader, R. Causey, R. Conn, R. Doerner, P. Efthimion, M. Finkenthal, D. Hoffman, B. Jones, R. Kaita, H. Kugel, S. Luckhardt, R. Maingi, M. Maiorano, T. Munsat, S. Raftopoulos, T. Rognlein, J. Spaleta, V. Soukhanovskii, D. Stutman, G. Taylor, J. Timberlake, M. Ulrickson, D. Whyte
{"title":"CDX-U环形液体锂限流器","authors":"R. Majeski, G. Antar, M. Boaz, D. Buchenauer, L. Cadwallader, R. Causey, R. Conn, R. Doerner, P. Efthimion, M. Finkenthal, D. Hoffman, B. Jones, R. Kaita, H. Kugel, S. Luckhardt, R. Maingi, M. Maiorano, T. Munsat, S. Raftopoulos, T. Rognlein, J. Spaleta, V. Soukhanovskii, D. Stutman, G. Taylor, J. Timberlake, M. Ulrickson, D. Whyte","doi":"10.1109/FUSION.2002.1027707","DOIUrl":null,"url":null,"abstract":"Attention has focused recently on flowing liquid lithium as a first wall for a reactor because of its potentially attractive physics and engineering features. In order to test the suitability of liquid lithium as a plasma facing component, the Current Drive eXperiment - Upgrade (CDX-U) at the Princeton Plasma Physics Laboratory has recently installed a fully toroidal liquid lithium limiter. CDX-U is a compact (R = 34 cm, a = 22 cm, B/sub toroidal/ = 2 kG, I/sub p/ =100 kA, T/sub e/(O) /spl sim/ 100 eV, n/sub e/(0) /spl sim/ 5 /spl times/ 10/sup 19/ m/sup -3/ short-pulse (< 25 msec) spherical torus (ST) with extensive diagnostics. The limiter, which consists of a shallow circular stainless steel tray of radius 34 cm and width 10 cm, is filled with lithium to a depth of a few millimeters, and forms the lower limiting surface for the discharge. Heating elements beneath the tray are used to liquefy the lithium (melting point = 180.5/spl deg/C) prior to the experiment. The total area of liquid lithium exposed to the plasma is approximately 2000 cm/sup 2/. The design of the limiter, modifications to CDX-U to accommodate in-vessel inventories of approximately 1 liter of liquid lithium, techniques for loading lithium onto the limiter, and other preparations will be described. CDX-U has previously been successfully operated with a smaller area cm/sup 2/) liquid lithium rail limiter. Diagnostics specific to lithium operations include multichord spectrometry of the 135 /spl Aring/ LiIII line in the core plasma, monitors for neutral lithium light at the lithium limiter, and a fast (10,000 frame per second) camera which monitors motion of the liquid during the discharge. First results of plasma operations with the toroidal liquid lithium limiter will also be given.","PeriodicalId":44192,"journal":{"name":"NINETEENTH CENTURY MUSIC","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2002-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A toroidal liquid lithium limiter for CDX-U\",\"authors\":\"R. Majeski, G. Antar, M. Boaz, D. Buchenauer, L. Cadwallader, R. Causey, R. Conn, R. Doerner, P. Efthimion, M. Finkenthal, D. Hoffman, B. Jones, R. Kaita, H. Kugel, S. Luckhardt, R. Maingi, M. Maiorano, T. Munsat, S. Raftopoulos, T. Rognlein, J. Spaleta, V. Soukhanovskii, D. Stutman, G. Taylor, J. Timberlake, M. Ulrickson, D. Whyte\",\"doi\":\"10.1109/FUSION.2002.1027707\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Attention has focused recently on flowing liquid lithium as a first wall for a reactor because of its potentially attractive physics and engineering features. In order to test the suitability of liquid lithium as a plasma facing component, the Current Drive eXperiment - Upgrade (CDX-U) at the Princeton Plasma Physics Laboratory has recently installed a fully toroidal liquid lithium limiter. CDX-U is a compact (R = 34 cm, a = 22 cm, B/sub toroidal/ = 2 kG, I/sub p/ =100 kA, T/sub e/(O) /spl sim/ 100 eV, n/sub e/(0) /spl sim/ 5 /spl times/ 10/sup 19/ m/sup -3/ short-pulse (< 25 msec) spherical torus (ST) with extensive diagnostics. The limiter, which consists of a shallow circular stainless steel tray of radius 34 cm and width 10 cm, is filled with lithium to a depth of a few millimeters, and forms the lower limiting surface for the discharge. Heating elements beneath the tray are used to liquefy the lithium (melting point = 180.5/spl deg/C) prior to the experiment. The total area of liquid lithium exposed to the plasma is approximately 2000 cm/sup 2/. The design of the limiter, modifications to CDX-U to accommodate in-vessel inventories of approximately 1 liter of liquid lithium, techniques for loading lithium onto the limiter, and other preparations will be described. CDX-U has previously been successfully operated with a smaller area cm/sup 2/) liquid lithium rail limiter. Diagnostics specific to lithium operations include multichord spectrometry of the 135 /spl Aring/ LiIII line in the core plasma, monitors for neutral lithium light at the lithium limiter, and a fast (10,000 frame per second) camera which monitors motion of the liquid during the discharge. First results of plasma operations with the toroidal liquid lithium limiter will also be given.\",\"PeriodicalId\":44192,\"journal\":{\"name\":\"NINETEENTH CENTURY MUSIC\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2002-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NINETEENTH CENTURY MUSIC\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FUSION.2002.1027707\",\"RegionNum\":1,\"RegionCategory\":\"艺术学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"MUSIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NINETEENTH CENTURY MUSIC","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.2002.1027707","RegionNum":1,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"MUSIC","Score":null,"Total":0}
引用次数: 0

摘要

由于液态锂在物理和工程上具有潜在的吸引力,人们最近把注意力集中在了液态锂作为反应堆的第一堵墙上。为了测试液体锂作为等离子体面向组件的适用性,普林斯顿等离子体物理实验室的电流驱动实验升级(CDX-U)最近安装了一个全环形液体锂限制器。CDX-U是一个紧凑的(R = 34 cm, a = 22 cm, B/sub环面/ = 2 kG, I/sub p/ =100 kA, T/sub e/(O) /spl sim/ 100 eV, n/sub e/(0) /spl sim/ 5 /spl times/ 10/sup 19/ m/sup -3/短脉冲(< 25 msec)球面环面(ST),具有广泛的诊断功能。限位器由一个半径34厘米、宽度10厘米的浅圆形不锈钢托盘组成,里面填充了几毫米深的锂,形成放电的下限表面。在实验之前,托盘下面的加热元件用于液化锂(熔点= 180.5/spl℃)。暴露在等离子体中的液态锂的总面积约为2000cm /sup /。本文将介绍限流器的设计、对CDX-U进行修改以适应约1升液体锂的容器库存、将锂装载到限流器上的技术以及其他准备工作。CDX-U之前已经成功地使用了面积更小(cm/sup 2/)的液态锂轨限制器。针对锂离子作业的诊断包括对核心等离子体中135 /spl的Aring/ LiIII线进行多弦光谱分析,在锂限制器处监测中性锂光,以及在放电过程中监测液体运动的快速(每秒10,000帧)相机。还将给出环形液体锂限制器等离子体操作的初步结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A toroidal liquid lithium limiter for CDX-U
Attention has focused recently on flowing liquid lithium as a first wall for a reactor because of its potentially attractive physics and engineering features. In order to test the suitability of liquid lithium as a plasma facing component, the Current Drive eXperiment - Upgrade (CDX-U) at the Princeton Plasma Physics Laboratory has recently installed a fully toroidal liquid lithium limiter. CDX-U is a compact (R = 34 cm, a = 22 cm, B/sub toroidal/ = 2 kG, I/sub p/ =100 kA, T/sub e/(O) /spl sim/ 100 eV, n/sub e/(0) /spl sim/ 5 /spl times/ 10/sup 19/ m/sup -3/ short-pulse (< 25 msec) spherical torus (ST) with extensive diagnostics. The limiter, which consists of a shallow circular stainless steel tray of radius 34 cm and width 10 cm, is filled with lithium to a depth of a few millimeters, and forms the lower limiting surface for the discharge. Heating elements beneath the tray are used to liquefy the lithium (melting point = 180.5/spl deg/C) prior to the experiment. The total area of liquid lithium exposed to the plasma is approximately 2000 cm/sup 2/. The design of the limiter, modifications to CDX-U to accommodate in-vessel inventories of approximately 1 liter of liquid lithium, techniques for loading lithium onto the limiter, and other preparations will be described. CDX-U has previously been successfully operated with a smaller area cm/sup 2/) liquid lithium rail limiter. Diagnostics specific to lithium operations include multichord spectrometry of the 135 /spl Aring/ LiIII line in the core plasma, monitors for neutral lithium light at the lithium limiter, and a fast (10,000 frame per second) camera which monitors motion of the liquid during the discharge. First results of plasma operations with the toroidal liquid lithium limiter will also be given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
11
期刊介绍: 19th-Century Music covers all aspects of Western art music between the mid-eighteenth and mid-twentieth centuries. We welcome--in no particular order--considerations of composers and compositions, styles, performance, historical watersheds, cultural formations, critical methods, musical institutions, ideas, and topics not named on this list. Our aim is to publish contributions to ongoing conversations at the leading edge of musical and multidisciplinary scholarship.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信