{"title":"光纤传感器用于桥梁监测","authors":"Amal Jayawardena, G. Appuhamillage","doi":"10.31357/AIT.V1I2.4938","DOIUrl":null,"url":null,"abstract":"This paper presents the data obtained from monitoring a steel Struss bridge using Fiber Bragg Grating (FBG) sensors before and after a proposed repair for a crack propagation in the end plates. This paper details the operating mechanism behind the FBG sensors and advantages of using FBG sensors over resistive foil strain gauges for bridge structural health monitoring and also details how cracks on the outer web’s end plate originated and then provides a step-by-step guide to the completed repair. This technology can be use in other practical applications where structural health monitoring is needed.","PeriodicalId":52314,"journal":{"name":"Advances in Technology Innovation","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Using Fiber Optic Sensors for Bridge Monitoring\",\"authors\":\"Amal Jayawardena, G. Appuhamillage\",\"doi\":\"10.31357/AIT.V1I2.4938\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the data obtained from monitoring a steel Struss bridge using Fiber Bragg Grating (FBG) sensors before and after a proposed repair for a crack propagation in the end plates. This paper details the operating mechanism behind the FBG sensors and advantages of using FBG sensors over resistive foil strain gauges for bridge structural health monitoring and also details how cracks on the outer web’s end plate originated and then provides a step-by-step guide to the completed repair. This technology can be use in other practical applications where structural health monitoring is needed.\",\"PeriodicalId\":52314,\"journal\":{\"name\":\"Advances in Technology Innovation\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Technology Innovation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31357/AIT.V1I2.4938\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Technology Innovation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31357/AIT.V1I2.4938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
This paper presents the data obtained from monitoring a steel Struss bridge using Fiber Bragg Grating (FBG) sensors before and after a proposed repair for a crack propagation in the end plates. This paper details the operating mechanism behind the FBG sensors and advantages of using FBG sensors over resistive foil strain gauges for bridge structural health monitoring and also details how cracks on the outer web’s end plate originated and then provides a step-by-step guide to the completed repair. This technology can be use in other practical applications where structural health monitoring is needed.