人眼模型介电值对射频暴露后比吸收率的影响

Lei Zhao, Dong-fang Liu, Geng Chen, Qin Ye
{"title":"人眼模型介电值对射频暴露后比吸收率的影响","authors":"Lei Zhao, Dong-fang Liu, Geng Chen, Qin Ye","doi":"10.1109/IMWS-BIO.2013.6756169","DOIUrl":null,"url":null,"abstract":"Specific absorption rate (SAR) is employed here to study the relationship between the radiation of a mobile handset and the human eye models. In the paper, the SAR in two human eye models, whose dielectric values are increased from the original by ±10% and ±20% are studied using the finite-difference time-domain method. A dipole antenna is used as an exposure source at 1800MHz. Through the simulation, the averaged values of SAR per 1g tissue and point SAR at frequency 1800MHz are obtained. The simulation results show that the variation of maximum averaged 1g SAR values is less than 12% when the dielectric properties change up to 20% at the operationfrequency of 1800 MHz. The variation of point SAR values is almost 30% when the dielectric properties change up to 20% at the operationfrequency of 1800 MHz.","PeriodicalId":6321,"journal":{"name":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","volume":"115 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effects of dielectric values of human eye models on specific absorption rate following rf exposure\",\"authors\":\"Lei Zhao, Dong-fang Liu, Geng Chen, Qin Ye\",\"doi\":\"10.1109/IMWS-BIO.2013.6756169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Specific absorption rate (SAR) is employed here to study the relationship between the radiation of a mobile handset and the human eye models. In the paper, the SAR in two human eye models, whose dielectric values are increased from the original by ±10% and ±20% are studied using the finite-difference time-domain method. A dipole antenna is used as an exposure source at 1800MHz. Through the simulation, the averaged values of SAR per 1g tissue and point SAR at frequency 1800MHz are obtained. The simulation results show that the variation of maximum averaged 1g SAR values is less than 12% when the dielectric properties change up to 20% at the operationfrequency of 1800 MHz. The variation of point SAR values is almost 30% when the dielectric properties change up to 20% at the operationfrequency of 1800 MHz.\",\"PeriodicalId\":6321,\"journal\":{\"name\":\"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)\",\"volume\":\"115 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMWS-BIO.2013.6756169\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMWS-BIO.2013.6756169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文采用比吸收率(SAR)来研究手机辐射与人眼模型的关系。本文采用时域有限差分方法,研究了介电值分别比原来增加±10%和±20%的人眼模型的SAR。偶极天线被用作1800兆赫的暴露源。通过仿真得到了每1g组织的SAR平均值和1800MHz频率下的点SAR值。仿真结果表明,在工作频率为1800 MHz时,当介电特性变化高达20%时,最大平均1g SAR值的变化小于12%。在工作频率为1800 MHz时,当介电特性变化高达20%时,点SAR值的变化幅度接近30%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of dielectric values of human eye models on specific absorption rate following rf exposure
Specific absorption rate (SAR) is employed here to study the relationship between the radiation of a mobile handset and the human eye models. In the paper, the SAR in two human eye models, whose dielectric values are increased from the original by ±10% and ±20% are studied using the finite-difference time-domain method. A dipole antenna is used as an exposure source at 1800MHz. Through the simulation, the averaged values of SAR per 1g tissue and point SAR at frequency 1800MHz are obtained. The simulation results show that the variation of maximum averaged 1g SAR values is less than 12% when the dielectric properties change up to 20% at the operationfrequency of 1800 MHz. The variation of point SAR values is almost 30% when the dielectric properties change up to 20% at the operationfrequency of 1800 MHz.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信