可编程温度蒸发器减少食品中农药残留分析中的基质效应

Q3 Pharmacology, Toxicology and Pharmaceutics
Vitae Pub Date : 2013-12-17 DOI:10.17533/udea.vitae.11056
D. A. AHUMADA FORIGUA, J. A. GUERRERO DALLOS
{"title":"可编程温度蒸发器减少食品中农药残留分析中的基质效应","authors":"D. A. AHUMADA FORIGUA, J. A. GUERRERO DALLOS","doi":"10.17533/udea.vitae.11056","DOIUrl":null,"url":null,"abstract":"Background: The phenomenon known as the “matrix-induced chromatographic response enhancement” commonly affects the sensibility, precision, and accuracy in pesticide residue analysis. The presence of matrix effects can be given by adsorption and/or thermal decomposition of pesticides on the gas chromatograph injection port. Objective: To reduce the matrix-induced chromatographic response enhancement on pesticide residues analysis in food through the use of several operational modes of programmable temperature vaporizer inlet. Methods: The analyses were carried out in potato (Solanum tuberosum) extracts by gas chromatography with mass spectrometry detector. In this study, four programmable temperature vaporizer splitless modes were investigated: hot, pulsed, cold and solvent vent. Another topic developed in this study has to do with the influence of injection volume, assessed for the matrix effects. Results: The analysis of variance (ANOVA) (α = 0.05) indicates that when the hot splitless is used most compounds are subjected to matrix-induced chromatographic response enhancement. Furthermore, with the pulsed splitless, a decrease in the number of compounds with matrix-induced chromatographic response enhancement was found, approximately 20% compared to the classic hot splitless. Finally, a remarkable decrease in matrix-induced effects was found when cold splitless mode was used, since there was up to 55% reduction in the compounds, relative to traditional hot splitless, that showed statistical differences between responses in matrix-free standards and matrix-matched standards. Conclusions: It was found that the use of conventional hot splitless and pulsed splitless modes caused matrix-induced effects in more than 70% of the studied compounds. In addition, the results indicate that for most compounds there is an inverse relationship between matrix-induced chromatographic response enhancement and the volume of injection.","PeriodicalId":51213,"journal":{"name":"Vitae","volume":"46 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2013-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reduction of matrix effects in pesticide residue analysis in food by programmable temperature vaporizer\",\"authors\":\"D. A. AHUMADA FORIGUA, J. A. GUERRERO DALLOS\",\"doi\":\"10.17533/udea.vitae.11056\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The phenomenon known as the “matrix-induced chromatographic response enhancement” commonly affects the sensibility, precision, and accuracy in pesticide residue analysis. The presence of matrix effects can be given by adsorption and/or thermal decomposition of pesticides on the gas chromatograph injection port. Objective: To reduce the matrix-induced chromatographic response enhancement on pesticide residues analysis in food through the use of several operational modes of programmable temperature vaporizer inlet. Methods: The analyses were carried out in potato (Solanum tuberosum) extracts by gas chromatography with mass spectrometry detector. In this study, four programmable temperature vaporizer splitless modes were investigated: hot, pulsed, cold and solvent vent. Another topic developed in this study has to do with the influence of injection volume, assessed for the matrix effects. Results: The analysis of variance (ANOVA) (α = 0.05) indicates that when the hot splitless is used most compounds are subjected to matrix-induced chromatographic response enhancement. Furthermore, with the pulsed splitless, a decrease in the number of compounds with matrix-induced chromatographic response enhancement was found, approximately 20% compared to the classic hot splitless. Finally, a remarkable decrease in matrix-induced effects was found when cold splitless mode was used, since there was up to 55% reduction in the compounds, relative to traditional hot splitless, that showed statistical differences between responses in matrix-free standards and matrix-matched standards. Conclusions: It was found that the use of conventional hot splitless and pulsed splitless modes caused matrix-induced effects in more than 70% of the studied compounds. In addition, the results indicate that for most compounds there is an inverse relationship between matrix-induced chromatographic response enhancement and the volume of injection.\",\"PeriodicalId\":51213,\"journal\":{\"name\":\"Vitae\",\"volume\":\"46 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vitae\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17533/udea.vitae.11056\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Pharmacology, Toxicology and Pharmaceutics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vitae","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17533/udea.vitae.11056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

摘要

背景:在农药残留分析中,“基质诱导色谱响应增强”现象经常影响灵敏度、精密度和准确性。基质效应的存在可以通过农药在气相色谱仪进样口的吸附和/或热分解得到。目的:通过可编程温度蒸发器入口的几种操作模式,减少基质诱导色谱在食品中农药残留分析中的响应增强。方法:采用气相色谱-质谱联用法对马铃薯提取物进行分析。在这项研究中,研究了四种可编程温度汽化器无分裂模式:热,脉冲,冷和溶剂排气。本研究中发展的另一个主题与注射量的影响有关,评估了基质效应。结果:方差分析(ANOVA) (α = 0.05)表明,当使用热裂解时,大多数化合物的基质诱导色谱响应增强。此外,与经典的热无劈裂相比,脉冲无劈裂使基质诱导色谱响应增强的化合物数量减少了约20%。最后,当使用冷无分裂模式时,发现基质诱导效应显著降低,因为与传统的热无分裂模式相比,化合物减少了55%,这表明在无基质标准和基质匹配标准之间的响应存在统计学差异。结论:使用传统的热无裂和脉冲无裂模式对70%以上的化合物产生基质诱导效应。此外,结果表明,对于大多数化合物,基质诱导的色谱响应增强与进样体积呈反比关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reduction of matrix effects in pesticide residue analysis in food by programmable temperature vaporizer
Background: The phenomenon known as the “matrix-induced chromatographic response enhancement” commonly affects the sensibility, precision, and accuracy in pesticide residue analysis. The presence of matrix effects can be given by adsorption and/or thermal decomposition of pesticides on the gas chromatograph injection port. Objective: To reduce the matrix-induced chromatographic response enhancement on pesticide residues analysis in food through the use of several operational modes of programmable temperature vaporizer inlet. Methods: The analyses were carried out in potato (Solanum tuberosum) extracts by gas chromatography with mass spectrometry detector. In this study, four programmable temperature vaporizer splitless modes were investigated: hot, pulsed, cold and solvent vent. Another topic developed in this study has to do with the influence of injection volume, assessed for the matrix effects. Results: The analysis of variance (ANOVA) (α = 0.05) indicates that when the hot splitless is used most compounds are subjected to matrix-induced chromatographic response enhancement. Furthermore, with the pulsed splitless, a decrease in the number of compounds with matrix-induced chromatographic response enhancement was found, approximately 20% compared to the classic hot splitless. Finally, a remarkable decrease in matrix-induced effects was found when cold splitless mode was used, since there was up to 55% reduction in the compounds, relative to traditional hot splitless, that showed statistical differences between responses in matrix-free standards and matrix-matched standards. Conclusions: It was found that the use of conventional hot splitless and pulsed splitless modes caused matrix-induced effects in more than 70% of the studied compounds. In addition, the results indicate that for most compounds there is an inverse relationship between matrix-induced chromatographic response enhancement and the volume of injection.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Vitae
Vitae PHARMACOLOGY & PHARMACY-
CiteScore
1.20
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: The journal VITAE is the four-monthly official publication of the School of Pharmaceutical and Food Sciences, and its mission is the diffusion of the scientific and investigative knowledge in the various fields of pharmaceutical and food research, and their related industries. The Journal VITAE is an open-access journal that publishes original and unpublished manuscripts, which are selected by the Editorial Board and then peer-reviewed. The editorial pages express the opinion of the Faculty regarding the various topics of interest. The judgments, opinions, and points of view expressed in the published articles are the responsibility of their authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信