{"title":"差分脉冲伏安法同时测定药物制剂中氨氯地平和氢氯噻嗪的含量","authors":"B. Yılmaz, Umit Kocak","doi":"10.21608/APRH.2018.5851.1068","DOIUrl":null,"url":null,"abstract":"Objectives: In this study, a new, fast and reliable differential pulse voltammetry (DPV) method was developed and validated for the simultaneous determination of amlodipine (AML) and hydrochlorothiazide(HCT) in pharmaceutical preparations. Methods: Electrochemical behavior and simultaneous voltammetric determination of AML and HCT were investigated using glassy carbon electrode. Validation parameters such as specificity, linearity, accuracy, precision, ruggedness, stability, limit of quantification and limit of detection were studied according to the International Conference on Harmonisation (ICH) Guidelines. Results: The linearity of this developed method was established in the concentration range of 2.5-30 μg/mL for AML and HCT, respectively. The precision was less than 5.34 and 2.91 %, determined from quality control samples for AML and HCT, and accuracy was within 2.57 and 3.60 % in terms of relative error, respectively. The percentage recovery obtained for AML and HCT in pharmaceutical preparations were 99.6 and 100.1 %, respectively. Limits of detection and quantification for AML and HCT were 0.80 and 2.40 µg/mL, respectively. Conclusion: The developed DPV method can be used for routine analysis of AML and HCT in pharmaceutical preparations.","PeriodicalId":15017,"journal":{"name":"Journal of Advanced Pharmacy Research","volume":"50 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous Determination of Amlodipine and Hydrochlorothiazide in Pharmaceutical Preparations by Differential Pulse Voltammetry Method\",\"authors\":\"B. Yılmaz, Umit Kocak\",\"doi\":\"10.21608/APRH.2018.5851.1068\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives: In this study, a new, fast and reliable differential pulse voltammetry (DPV) method was developed and validated for the simultaneous determination of amlodipine (AML) and hydrochlorothiazide(HCT) in pharmaceutical preparations. Methods: Electrochemical behavior and simultaneous voltammetric determination of AML and HCT were investigated using glassy carbon electrode. Validation parameters such as specificity, linearity, accuracy, precision, ruggedness, stability, limit of quantification and limit of detection were studied according to the International Conference on Harmonisation (ICH) Guidelines. Results: The linearity of this developed method was established in the concentration range of 2.5-30 μg/mL for AML and HCT, respectively. The precision was less than 5.34 and 2.91 %, determined from quality control samples for AML and HCT, and accuracy was within 2.57 and 3.60 % in terms of relative error, respectively. The percentage recovery obtained for AML and HCT in pharmaceutical preparations were 99.6 and 100.1 %, respectively. Limits of detection and quantification for AML and HCT were 0.80 and 2.40 µg/mL, respectively. Conclusion: The developed DPV method can be used for routine analysis of AML and HCT in pharmaceutical preparations.\",\"PeriodicalId\":15017,\"journal\":{\"name\":\"Journal of Advanced Pharmacy Research\",\"volume\":\"50 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Pharmacy Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/APRH.2018.5851.1068\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Pharmacy Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/APRH.2018.5851.1068","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simultaneous Determination of Amlodipine and Hydrochlorothiazide in Pharmaceutical Preparations by Differential Pulse Voltammetry Method
Objectives: In this study, a new, fast and reliable differential pulse voltammetry (DPV) method was developed and validated for the simultaneous determination of amlodipine (AML) and hydrochlorothiazide(HCT) in pharmaceutical preparations. Methods: Electrochemical behavior and simultaneous voltammetric determination of AML and HCT were investigated using glassy carbon electrode. Validation parameters such as specificity, linearity, accuracy, precision, ruggedness, stability, limit of quantification and limit of detection were studied according to the International Conference on Harmonisation (ICH) Guidelines. Results: The linearity of this developed method was established in the concentration range of 2.5-30 μg/mL for AML and HCT, respectively. The precision was less than 5.34 and 2.91 %, determined from quality control samples for AML and HCT, and accuracy was within 2.57 and 3.60 % in terms of relative error, respectively. The percentage recovery obtained for AML and HCT in pharmaceutical preparations were 99.6 and 100.1 %, respectively. Limits of detection and quantification for AML and HCT were 0.80 and 2.40 µg/mL, respectively. Conclusion: The developed DPV method can be used for routine analysis of AML and HCT in pharmaceutical preparations.