故障检测与隔离问题:滑模模糊观测器与神经网络

J. Anzurez-Marín, E. Espinosa-Juárez, B. Castillo-Toledo
{"title":"故障检测与隔离问题:滑模模糊观测器与神经网络","authors":"J. Anzurez-Marín, E. Espinosa-Juárez, B. Castillo-Toledo","doi":"10.1109/ICEEE.2014.6978328","DOIUrl":null,"url":null,"abstract":"In this paper results of the application of a hybrid Fault Detection and Isolation scheme are presented. A Takagi-Sugeno fuzzy model is used to describe the system and a type of sliding mode observers are designed to estimate the system state vector; from this, the diagnostic signal-residual is generated by the comparison of measured and estimated output. Neural Networks are proposed in order to solve the fault isolation problem based on signal-residual. The faulted component is identified from the active signal-residuals by means of the application of the presented technique based on neural networks. This paper shows an application of the fault diagnosis technique, which was satisfactorily tested in a two-tank hydraulic system.","PeriodicalId":6661,"journal":{"name":"2014 11th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE)","volume":"102 1","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fault detection and isolation problem: Sliding mode fuzzy observers and neural networks\",\"authors\":\"J. Anzurez-Marín, E. Espinosa-Juárez, B. Castillo-Toledo\",\"doi\":\"10.1109/ICEEE.2014.6978328\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper results of the application of a hybrid Fault Detection and Isolation scheme are presented. A Takagi-Sugeno fuzzy model is used to describe the system and a type of sliding mode observers are designed to estimate the system state vector; from this, the diagnostic signal-residual is generated by the comparison of measured and estimated output. Neural Networks are proposed in order to solve the fault isolation problem based on signal-residual. The faulted component is identified from the active signal-residuals by means of the application of the presented technique based on neural networks. This paper shows an application of the fault diagnosis technique, which was satisfactorily tested in a two-tank hydraulic system.\",\"PeriodicalId\":6661,\"journal\":{\"name\":\"2014 11th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE)\",\"volume\":\"102 1\",\"pages\":\"1-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 11th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEEE.2014.6978328\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 11th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEEE.2014.6978328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文给出了一种混合故障检测和隔离方案的应用结果。采用Takagi-Sugeno模糊模型对系统进行描述,设计一种滑模观测器对系统状态向量进行估计;在此基础上,通过测量输出和估计输出的比较,产生诊断信号残差。为了解决基于信号残差的故障隔离问题,提出了神经网络。将该方法应用于基于神经网络的有源信号残差中进行故障分量的识别。本文介绍了故障诊断技术在双油箱液压系统中的应用,并取得了满意的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault detection and isolation problem: Sliding mode fuzzy observers and neural networks
In this paper results of the application of a hybrid Fault Detection and Isolation scheme are presented. A Takagi-Sugeno fuzzy model is used to describe the system and a type of sliding mode observers are designed to estimate the system state vector; from this, the diagnostic signal-residual is generated by the comparison of measured and estimated output. Neural Networks are proposed in order to solve the fault isolation problem based on signal-residual. The faulted component is identified from the active signal-residuals by means of the application of the presented technique based on neural networks. This paper shows an application of the fault diagnosis technique, which was satisfactorily tested in a two-tank hydraulic system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信