{"title":"计算机动画数字电弧诊断系统","authors":"J. Shea, D. Boles, Y. Chien, R. Zeigler","doi":"10.1109/HOLM.1993.489682","DOIUrl":null,"url":null,"abstract":"An arc diagnostic system has been developed for analyzing arc motion, structure, and intensity in electrical components such as molded case circuit breakers and contactors. The system utilizes an array of fiber-optic cables and matching photodiode receivers to monitor the light from an arc and convert the light into electrical signals which are acquired by a high speed transient digitizing system. The two unique aspects of this system are in the animation and arc intensity capabilities. Acquired images of the arc (up to 1 image per microsecond) are superimposed on a CAD drawing of the device being tested and reanimated frame by frame on a personal computer screen. Arc intensity is proportional to the spot size shown in the reanimation. The system can also acquire corresponding current, arc voltage, and arc chamber pressure which are correlated to the reanimation. High power short circuit tests were performed on a current limiting molded case circuit breaker (MCCB) to illustrate system capabilities. Discussions about the acquired results are made as well as future refinements to the system.","PeriodicalId":11624,"journal":{"name":"Electrical Contacts - 2007 Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts","volume":"185 1","pages":"237-243"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Computer animated digital arc diagnostic system\",\"authors\":\"J. Shea, D. Boles, Y. Chien, R. Zeigler\",\"doi\":\"10.1109/HOLM.1993.489682\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An arc diagnostic system has been developed for analyzing arc motion, structure, and intensity in electrical components such as molded case circuit breakers and contactors. The system utilizes an array of fiber-optic cables and matching photodiode receivers to monitor the light from an arc and convert the light into electrical signals which are acquired by a high speed transient digitizing system. The two unique aspects of this system are in the animation and arc intensity capabilities. Acquired images of the arc (up to 1 image per microsecond) are superimposed on a CAD drawing of the device being tested and reanimated frame by frame on a personal computer screen. Arc intensity is proportional to the spot size shown in the reanimation. The system can also acquire corresponding current, arc voltage, and arc chamber pressure which are correlated to the reanimation. High power short circuit tests were performed on a current limiting molded case circuit breaker (MCCB) to illustrate system capabilities. Discussions about the acquired results are made as well as future refinements to the system.\",\"PeriodicalId\":11624,\"journal\":{\"name\":\"Electrical Contacts - 2007 Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts\",\"volume\":\"185 1\",\"pages\":\"237-243\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrical Contacts - 2007 Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.1993.489682\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Contacts - 2007 Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.1993.489682","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

电弧诊断系统已开发用于分析电弧运动,结构和强度的电气元件,如模壳断路器和接触器。该系统利用一组光纤电缆和匹配的光电二极管接收器来监测来自电弧的光,并将光转换为电信号,该电信号由高速瞬态数字化系统获取。该系统的两个独特方面是动画和弧强度能力。获取的弧线图像(每微秒最多1张图像)叠加在被测设备的CAD绘图上,并在个人电脑屏幕上逐帧重新显示。电弧强度与再现图中显示的光斑大小成正比。该系统还可以获取与再激活相关的相应电流、电弧电压和电弧室压力。对限流塑壳断路器(MCCB)进行了大功率短路试验,以说明系统性能。讨论了获得的结果,并对系统进行了进一步的改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computer animated digital arc diagnostic system
An arc diagnostic system has been developed for analyzing arc motion, structure, and intensity in electrical components such as molded case circuit breakers and contactors. The system utilizes an array of fiber-optic cables and matching photodiode receivers to monitor the light from an arc and convert the light into electrical signals which are acquired by a high speed transient digitizing system. The two unique aspects of this system are in the animation and arc intensity capabilities. Acquired images of the arc (up to 1 image per microsecond) are superimposed on a CAD drawing of the device being tested and reanimated frame by frame on a personal computer screen. Arc intensity is proportional to the spot size shown in the reanimation. The system can also acquire corresponding current, arc voltage, and arc chamber pressure which are correlated to the reanimation. High power short circuit tests were performed on a current limiting molded case circuit breaker (MCCB) to illustrate system capabilities. Discussions about the acquired results are made as well as future refinements to the system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信