Nde Masia, M. Smit, IA Mwamba, L. Fowler, L. Chown, S. Norgren, C. Öhman-Mägi, N. Hashe, L. Cornish
{"title":"生物医学应用Ti-Cu合金的腐蚀性能","authors":"Nde Masia, M. Smit, IA Mwamba, L. Fowler, L. Chown, S. Norgren, C. Öhman-Mägi, N. Hashe, L. Cornish","doi":"10.36303/satnt.2021cosaami.45","DOIUrl":null,"url":null,"abstract":"The Thermo-Calc™ program and TTTI3 database were used to predict the phases in Ti-Cu with 5, 25, and 40 wt% Cu. Based on the predicted results, experimental work was conducted and the Ti-Cu alloys were produced in a button arc furnace, and characterised in the as-cast and the annealed condition (900°C) followed by water quenching. Microstructures and compositions were determined using an electron probe micro-analyser, and the phases were identified by X-ray diffraction. The corrosion performance was measured by potentiodynamic polarisation in a phosphate buffered saline solution at 37 °C at 7.4 pH while purging with nitrogen gas. The Ti-5Cu and Ti-25Cu alloys comprised (αTi) and Ti2Cu phases, the Ti-40Cu alloy comprised Ti2Cu and TiCu. Although the addition of copper decreased the corrosion performance by down to 75%, the corrosion rates were still within the acceptable range (0.02-0.13 mm/y) for biocompatibility of metallic implants. Annealing at 900 °C did not improve the corrosion performance.","PeriodicalId":22035,"journal":{"name":"Suid-Afrikaanse Tydskrif vir Natuurwetenskap en Tegnologie","volume":"60 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Corrosion performance of Ti-Cu alloys targeted for biomedical applications\",\"authors\":\"Nde Masia, M. Smit, IA Mwamba, L. Fowler, L. Chown, S. Norgren, C. Öhman-Mägi, N. Hashe, L. Cornish\",\"doi\":\"10.36303/satnt.2021cosaami.45\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Thermo-Calc™ program and TTTI3 database were used to predict the phases in Ti-Cu with 5, 25, and 40 wt% Cu. Based on the predicted results, experimental work was conducted and the Ti-Cu alloys were produced in a button arc furnace, and characterised in the as-cast and the annealed condition (900°C) followed by water quenching. Microstructures and compositions were determined using an electron probe micro-analyser, and the phases were identified by X-ray diffraction. The corrosion performance was measured by potentiodynamic polarisation in a phosphate buffered saline solution at 37 °C at 7.4 pH while purging with nitrogen gas. The Ti-5Cu and Ti-25Cu alloys comprised (αTi) and Ti2Cu phases, the Ti-40Cu alloy comprised Ti2Cu and TiCu. Although the addition of copper decreased the corrosion performance by down to 75%, the corrosion rates were still within the acceptable range (0.02-0.13 mm/y) for biocompatibility of metallic implants. Annealing at 900 °C did not improve the corrosion performance.\",\"PeriodicalId\":22035,\"journal\":{\"name\":\"Suid-Afrikaanse Tydskrif vir Natuurwetenskap en Tegnologie\",\"volume\":\"60 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Suid-Afrikaanse Tydskrif vir Natuurwetenskap en Tegnologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36303/satnt.2021cosaami.45\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Suid-Afrikaanse Tydskrif vir Natuurwetenskap en Tegnologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36303/satnt.2021cosaami.45","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Corrosion performance of Ti-Cu alloys targeted for biomedical applications
The Thermo-Calc™ program and TTTI3 database were used to predict the phases in Ti-Cu with 5, 25, and 40 wt% Cu. Based on the predicted results, experimental work was conducted and the Ti-Cu alloys were produced in a button arc furnace, and characterised in the as-cast and the annealed condition (900°C) followed by water quenching. Microstructures and compositions were determined using an electron probe micro-analyser, and the phases were identified by X-ray diffraction. The corrosion performance was measured by potentiodynamic polarisation in a phosphate buffered saline solution at 37 °C at 7.4 pH while purging with nitrogen gas. The Ti-5Cu and Ti-25Cu alloys comprised (αTi) and Ti2Cu phases, the Ti-40Cu alloy comprised Ti2Cu and TiCu. Although the addition of copper decreased the corrosion performance by down to 75%, the corrosion rates were still within the acceptable range (0.02-0.13 mm/y) for biocompatibility of metallic implants. Annealing at 900 °C did not improve the corrosion performance.