V. Bogacheva, V. Stepanenko, L. Krikunova, A. Petukhov, G. Kulieva, T.V. Kolyshenkov, E. Zharova, V. A. Korotkov, S. A. Ivanov, P. Shegay, A. Kaprin
{"title":"高剂量率近距离放疗在妇科肿瘤中的腔内“体内”剂量测定","authors":"V. Bogacheva, V. Stepanenko, L. Krikunova, A. Petukhov, G. Kulieva, T.V. Kolyshenkov, E. Zharova, V. A. Korotkov, S. A. Ivanov, P. Shegay, A. Kaprin","doi":"10.21870/0131-3878-2022-31-4-119-131","DOIUrl":null,"url":null,"abstract":"The technology for construction and application of flexible dosimetric assemblies with LiF:Mg,Ti microcrystals (sizes of about 0.1 mm) for off-line measurements of the spatial distribution of the absorbed dose inside organs at risk (rectum, urethra, vagina) at high dose rate brachytherapy in oncoginecology has been developed. The transfer from the usage of luminescent dosimeters LiF:Mg,Ti with macro sizes (more than 1 mm) to microdosimetrs with sizes of about 0.1 mm, in combination with the developed protocols of dose estimations using mini-aliquots (10 mg) of lu-minescent microdosimeters, provided possibility to increase the accuracy of dose measurements in the therapeutic dose range at high dose rate brachytherapy of gynecological malignancies. The developed technology of intracavitary dosimetry at a high dose rate brachytherapy (Ir-129 source) in oncogynecology was tested in the clinic (25 patients). It was found that, as a rule, the measured doses were in a good agreement with the calculated doses in the areas of interest. However, in four cases (16% of all patients) there was an excess of the measured local absorbed doses over the calculated ones (from 0.6 to 1 Gy) in the urethra and rectum (in the organs of maximum calculated doses). These cases may be considered as a basis for monitoring of the patients’ condition in the post-therapeutic period. However, the values of maximal dose were within acceptable dose range, as recommended by GEC-ESTRO. The developed technology of «in vivo» dosimetry allows to adjust the dosimetrical plans at multifractional high dose rate brachytherapy. The results of clinical approbation of the developed technology of «in vivo» dosimetry show the importance of this technology as an essential element of dosimetric assurance of the quality of high dose rate brachytherapy in oncogynecology.","PeriodicalId":6315,"journal":{"name":"\"Radiation and Risk\" Bulletin of the National Radiation and Epidemiological Registry","volume":"25 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intracavitary «in vivo» dosimetry at the high dose rate brachytherapy in oncogynecology\",\"authors\":\"V. Bogacheva, V. Stepanenko, L. Krikunova, A. Petukhov, G. Kulieva, T.V. Kolyshenkov, E. Zharova, V. A. Korotkov, S. A. Ivanov, P. Shegay, A. Kaprin\",\"doi\":\"10.21870/0131-3878-2022-31-4-119-131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The technology for construction and application of flexible dosimetric assemblies with LiF:Mg,Ti microcrystals (sizes of about 0.1 mm) for off-line measurements of the spatial distribution of the absorbed dose inside organs at risk (rectum, urethra, vagina) at high dose rate brachytherapy in oncoginecology has been developed. The transfer from the usage of luminescent dosimeters LiF:Mg,Ti with macro sizes (more than 1 mm) to microdosimetrs with sizes of about 0.1 mm, in combination with the developed protocols of dose estimations using mini-aliquots (10 mg) of lu-minescent microdosimeters, provided possibility to increase the accuracy of dose measurements in the therapeutic dose range at high dose rate brachytherapy of gynecological malignancies. The developed technology of intracavitary dosimetry at a high dose rate brachytherapy (Ir-129 source) in oncogynecology was tested in the clinic (25 patients). It was found that, as a rule, the measured doses were in a good agreement with the calculated doses in the areas of interest. However, in four cases (16% of all patients) there was an excess of the measured local absorbed doses over the calculated ones (from 0.6 to 1 Gy) in the urethra and rectum (in the organs of maximum calculated doses). These cases may be considered as a basis for monitoring of the patients’ condition in the post-therapeutic period. However, the values of maximal dose were within acceptable dose range, as recommended by GEC-ESTRO. The developed technology of «in vivo» dosimetry allows to adjust the dosimetrical plans at multifractional high dose rate brachytherapy. The results of clinical approbation of the developed technology of «in vivo» dosimetry show the importance of this technology as an essential element of dosimetric assurance of the quality of high dose rate brachytherapy in oncogynecology.\",\"PeriodicalId\":6315,\"journal\":{\"name\":\"\\\"Radiation and Risk\\\" Bulletin of the National Radiation and Epidemiological Registry\",\"volume\":\"25 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\\\"Radiation and Risk\\\" Bulletin of the National Radiation and Epidemiological Registry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21870/0131-3878-2022-31-4-119-131\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"\"Radiation and Risk\" Bulletin of the National Radiation and Epidemiological Registry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21870/0131-3878-2022-31-4-119-131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用LiF:Mg,Ti微晶体(尺寸约为0.1 mm)构建和应用柔性剂量计组件的技术,用于离线测量肿瘤生态学中高剂量率近距离放射治疗中危险器官(直肠、尿道、阴道)内吸收剂量的空间分布。从使用宏观尺寸(大于1mm)的发光剂量计LiF:Mg,Ti转变为使用约0.1 mm尺寸的微剂量计,结合使用小当量(10mg)发光微剂量计的剂量估计方案,为提高高剂量率近距离妇科恶性肿瘤治疗剂量范围内剂量测量的准确性提供了可能。在妇科肿瘤的高剂量率近距离放射治疗(Ir-129源)中发展的腔内剂量测定技术在临床(25例患者)中进行了测试。结果发现,在有关地区,通常测量的剂量与计算的剂量是完全一致的。然而,在4例(占所有患者的16%)中,尿道和直肠(最大计算剂量的器官)的测量局部吸收剂量超过计算剂量(从0.6 Gy到1 Gy)。这些病例可作为治疗后患者病情监测的基础。然而,最大剂量值在可接受的剂量范围内,根据GEC-ESTRO推荐。发达的“体内”剂量测定技术允许在多段式高剂量率近距离治疗中调整剂量测量计划。“体内”剂量测定技术的临床批准结果表明,该技术作为保证妇科肿瘤近距离高剂量率放射治疗质量的剂量测定基本要素的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intracavitary «in vivo» dosimetry at the high dose rate brachytherapy in oncogynecology
The technology for construction and application of flexible dosimetric assemblies with LiF:Mg,Ti microcrystals (sizes of about 0.1 mm) for off-line measurements of the spatial distribution of the absorbed dose inside organs at risk (rectum, urethra, vagina) at high dose rate brachytherapy in oncoginecology has been developed. The transfer from the usage of luminescent dosimeters LiF:Mg,Ti with macro sizes (more than 1 mm) to microdosimetrs with sizes of about 0.1 mm, in combination with the developed protocols of dose estimations using mini-aliquots (10 mg) of lu-minescent microdosimeters, provided possibility to increase the accuracy of dose measurements in the therapeutic dose range at high dose rate brachytherapy of gynecological malignancies. The developed technology of intracavitary dosimetry at a high dose rate brachytherapy (Ir-129 source) in oncogynecology was tested in the clinic (25 patients). It was found that, as a rule, the measured doses were in a good agreement with the calculated doses in the areas of interest. However, in four cases (16% of all patients) there was an excess of the measured local absorbed doses over the calculated ones (from 0.6 to 1 Gy) in the urethra and rectum (in the organs of maximum calculated doses). These cases may be considered as a basis for monitoring of the patients’ condition in the post-therapeutic period. However, the values of maximal dose were within acceptable dose range, as recommended by GEC-ESTRO. The developed technology of «in vivo» dosimetry allows to adjust the dosimetrical plans at multifractional high dose rate brachytherapy. The results of clinical approbation of the developed technology of «in vivo» dosimetry show the importance of this technology as an essential element of dosimetric assurance of the quality of high dose rate brachytherapy in oncogynecology.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信