胶粘剂电老化

H. Narushima, Y. Tsukamoto, J. Koshimura
{"title":"胶粘剂电老化","authors":"H. Narushima, Y. Tsukamoto, J. Koshimura","doi":"10.1109/CEIDP.1989.69541","DOIUrl":null,"url":null,"abstract":"Insulating reliability between adjacent leads formed on organic material is an important problem for printed circuits. This problem was investigated in connection with insulator deterioration between copper conductors exposed to high temperature and high humidity under fairly high electric fields in comparison with actual operating conditions. The investigation was performed on a copper foil laminated to a thermoset adhesive coated on polyimide film. Abrupt and intermittent changes in leakage current were found to occur at high humidity and high temperature under field application. Before the abrupt change occurred, the corrosion expanded toward the cathode from the anode. Thereafter a copper component migrated to the cathode from the corrosion zone. The copper migration and the corrosion progressed through the adhesive, not along the surface. A similar failure phenomenon was observed for adhesives made of polyamide, epoxy, and phenolic resins, but their times to failure were quite different. This was attributed to their hydrolysis.<<ETX>>","PeriodicalId":10719,"journal":{"name":"Conference on Electrical Insulation and Dielectric Phenomena,","volume":"392 1","pages":"168-172"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Electrical aging of adhesive\",\"authors\":\"H. Narushima, Y. Tsukamoto, J. Koshimura\",\"doi\":\"10.1109/CEIDP.1989.69541\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Insulating reliability between adjacent leads formed on organic material is an important problem for printed circuits. This problem was investigated in connection with insulator deterioration between copper conductors exposed to high temperature and high humidity under fairly high electric fields in comparison with actual operating conditions. The investigation was performed on a copper foil laminated to a thermoset adhesive coated on polyimide film. Abrupt and intermittent changes in leakage current were found to occur at high humidity and high temperature under field application. Before the abrupt change occurred, the corrosion expanded toward the cathode from the anode. Thereafter a copper component migrated to the cathode from the corrosion zone. The copper migration and the corrosion progressed through the adhesive, not along the surface. A similar failure phenomenon was observed for adhesives made of polyamide, epoxy, and phenolic resins, but their times to failure were quite different. This was attributed to their hydrolysis.<<ETX>>\",\"PeriodicalId\":10719,\"journal\":{\"name\":\"Conference on Electrical Insulation and Dielectric Phenomena,\",\"volume\":\"392 1\",\"pages\":\"168-172\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference on Electrical Insulation and Dielectric Phenomena,\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1989.69541\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1989.69541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在有机材料上形成的相邻引线之间的绝缘可靠性是印刷电路的重要问题。研究了铜导体在高温高湿条件下的绝缘子劣化问题,并与实际工作条件进行了比较。以热固性胶粘剂涂覆在聚酰亚胺薄膜上的铜箔为研究对象。在现场应用中发现,在高湿高温条件下,漏电电流会发生突发性和间歇性的变化。在突变发生之前,腐蚀从阳极向阴极扩展。此后,铜组分从腐蚀区迁移到阴极。铜的迁移和腐蚀是通过粘合剂进行的,而不是沿着表面进行的。聚酰胺、环氧树脂和酚醛树脂制成的粘合剂也有类似的失效现象,但它们的失效时间大不相同。这是由于它们的水解作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrical aging of adhesive
Insulating reliability between adjacent leads formed on organic material is an important problem for printed circuits. This problem was investigated in connection with insulator deterioration between copper conductors exposed to high temperature and high humidity under fairly high electric fields in comparison with actual operating conditions. The investigation was performed on a copper foil laminated to a thermoset adhesive coated on polyimide film. Abrupt and intermittent changes in leakage current were found to occur at high humidity and high temperature under field application. Before the abrupt change occurred, the corrosion expanded toward the cathode from the anode. Thereafter a copper component migrated to the cathode from the corrosion zone. The copper migration and the corrosion progressed through the adhesive, not along the surface. A similar failure phenomenon was observed for adhesives made of polyamide, epoxy, and phenolic resins, but their times to failure were quite different. This was attributed to their hydrolysis.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信