Ping Song, Zheng Zhu, Wei-qiang Yao, Qi-qi Zhang, W. Si, P. Yuan
{"title":"基于声发射与超高频相结合的油内放电传感器在变压器放电检测中的应用,第二部分:实验验证","authors":"Ping Song, Zheng Zhu, Wei-qiang Yao, Qi-qi Zhang, W. Si, P. Yuan","doi":"10.1109/ICHVE49031.2020.9280014","DOIUrl":null,"url":null,"abstract":"A combined in-oil partial discharges (PD) sensor with acoustical emission (AE) and ultra high frequency (UHF) methods for PD detection in transformer is designed and developed, according to the disadvantages and advantages of electromagnetic and acoustic PD measurements shown in IEC TS 62478 Edition 1.0 2016–08. It is formed by placing an AE sensor inside the end part of UHF probe to fit for the transformer oil valve, which works independently of each other with two output channels for AE and UHF PD signals measurements. Test results of a 110 kV transformer with built-in tip, suspension and surface insulation defects show that the combined UHF/AE in-oil PD sensor designed and developed can effectively detect the electromagnetic wave and ultrasonic signal with a specific time difference $\\Delta\\mathbf{t}$ generated by the weak discharges in the transformer oil, which provides a new mixed electromagnetic and acoustic method for PD measurements of transformer.","PeriodicalId":6763,"journal":{"name":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","volume":"323 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel combined in-oil PD sensor with AE and UHF methods for PD detection in transformer, part 2: experimental verification\",\"authors\":\"Ping Song, Zheng Zhu, Wei-qiang Yao, Qi-qi Zhang, W. Si, P. Yuan\",\"doi\":\"10.1109/ICHVE49031.2020.9280014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A combined in-oil partial discharges (PD) sensor with acoustical emission (AE) and ultra high frequency (UHF) methods for PD detection in transformer is designed and developed, according to the disadvantages and advantages of electromagnetic and acoustic PD measurements shown in IEC TS 62478 Edition 1.0 2016–08. It is formed by placing an AE sensor inside the end part of UHF probe to fit for the transformer oil valve, which works independently of each other with two output channels for AE and UHF PD signals measurements. Test results of a 110 kV transformer with built-in tip, suspension and surface insulation defects show that the combined UHF/AE in-oil PD sensor designed and developed can effectively detect the electromagnetic wave and ultrasonic signal with a specific time difference $\\\\Delta\\\\mathbf{t}$ generated by the weak discharges in the transformer oil, which provides a new mixed electromagnetic and acoustic method for PD measurements of transformer.\",\"PeriodicalId\":6763,\"journal\":{\"name\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"volume\":\"323 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE49031.2020.9280014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE49031.2020.9280014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
根据IEC TS 62478 version 1.0 2016-08中电磁和声局部放电(PD)测量方法的优缺点,设计并开发了一种结合声发射和超高频(UHF)方法的油内局部放电(PD)传感器,用于变压器局部放电检测。它是在超高频探头的端部放置一个与变压器油阀相适应的声发射传感器而形成的,它们相互独立工作,有两个输出通道用于测量声发射和超高频PD信号。对110 kV变压器内置尖端、悬置和表面绝缘缺陷的试验结果表明,所设计研制的UHF/AE油内PD传感器能有效检测变压器油中弱放电产生的具有特定时差$\Delta\mathbf{t}$的电磁波和超声信号,为变压器PD测量提供了一种新的电磁声混合测量方法。
A novel combined in-oil PD sensor with AE and UHF methods for PD detection in transformer, part 2: experimental verification
A combined in-oil partial discharges (PD) sensor with acoustical emission (AE) and ultra high frequency (UHF) methods for PD detection in transformer is designed and developed, according to the disadvantages and advantages of electromagnetic and acoustic PD measurements shown in IEC TS 62478 Edition 1.0 2016–08. It is formed by placing an AE sensor inside the end part of UHF probe to fit for the transformer oil valve, which works independently of each other with two output channels for AE and UHF PD signals measurements. Test results of a 110 kV transformer with built-in tip, suspension and surface insulation defects show that the combined UHF/AE in-oil PD sensor designed and developed can effectively detect the electromagnetic wave and ultrasonic signal with a specific time difference $\Delta\mathbf{t}$ generated by the weak discharges in the transformer oil, which provides a new mixed electromagnetic and acoustic method for PD measurements of transformer.