Chengli Zhang, Dezhi Liang, Hai-qing Cui, D. Yin, Guoliang Song
{"title":"多组分泡沫驱堵塞能力数学模型的建立及敏感性分析","authors":"Chengli Zhang, Dezhi Liang, Hai-qing Cui, D. Yin, Guoliang Song","doi":"10.2174/1874123101509010084","DOIUrl":null,"url":null,"abstract":"Based on mass conservation, foam total amount balance thought and foam properties characterization model, a foam flooding mathematical model with three-phase and five components is established and numerically solved, the ex- plicit is used to solve the saturation equation and the implicit is used to solve the pressure equation in this model. By fit- ting the results of foam plugging capacity experiments and numerical calculation, the correctness of the model is verified. On this basis, the conceptual model is established to simulate and evaluate the sensitivity of influencing parameters of foam flooding plugging ability. The results show that: the plugging ability of foam system increases with the increase of foaming agent concentration. When the concentration of foaming agent is more than 0.3%, the resistance coefficient tends to steady; when gas-liquid ratio is 2:1, the foam plugging ability is the strongest. The plugging ability of foam system in- creases with the increase of permeability showing good permeability selectivity. If the permeability in the reservoir is higher then the profile control capability will also be stronger.","PeriodicalId":22933,"journal":{"name":"The Open Chemical Engineering Journal","volume":"38 1","pages":"84-89"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Establishment of Mathematical Model and Sensitivity Analysis of PluggingCapacity of Multi-Component Foam Flooding\",\"authors\":\"Chengli Zhang, Dezhi Liang, Hai-qing Cui, D. Yin, Guoliang Song\",\"doi\":\"10.2174/1874123101509010084\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on mass conservation, foam total amount balance thought and foam properties characterization model, a foam flooding mathematical model with three-phase and five components is established and numerically solved, the ex- plicit is used to solve the saturation equation and the implicit is used to solve the pressure equation in this model. By fit- ting the results of foam plugging capacity experiments and numerical calculation, the correctness of the model is verified. On this basis, the conceptual model is established to simulate and evaluate the sensitivity of influencing parameters of foam flooding plugging ability. The results show that: the plugging ability of foam system increases with the increase of foaming agent concentration. When the concentration of foaming agent is more than 0.3%, the resistance coefficient tends to steady; when gas-liquid ratio is 2:1, the foam plugging ability is the strongest. The plugging ability of foam system in- creases with the increase of permeability showing good permeability selectivity. If the permeability in the reservoir is higher then the profile control capability will also be stronger.\",\"PeriodicalId\":22933,\"journal\":{\"name\":\"The Open Chemical Engineering Journal\",\"volume\":\"38 1\",\"pages\":\"84-89\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Open Chemical Engineering Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1874123101509010084\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Open Chemical Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874123101509010084","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Establishment of Mathematical Model and Sensitivity Analysis of PluggingCapacity of Multi-Component Foam Flooding
Based on mass conservation, foam total amount balance thought and foam properties characterization model, a foam flooding mathematical model with three-phase and five components is established and numerically solved, the ex- plicit is used to solve the saturation equation and the implicit is used to solve the pressure equation in this model. By fit- ting the results of foam plugging capacity experiments and numerical calculation, the correctness of the model is verified. On this basis, the conceptual model is established to simulate and evaluate the sensitivity of influencing parameters of foam flooding plugging ability. The results show that: the plugging ability of foam system increases with the increase of foaming agent concentration. When the concentration of foaming agent is more than 0.3%, the resistance coefficient tends to steady; when gas-liquid ratio is 2:1, the foam plugging ability is the strongest. The plugging ability of foam system in- creases with the increase of permeability showing good permeability selectivity. If the permeability in the reservoir is higher then the profile control capability will also be stronger.