塑料和钢纤维加固对钢锚强度的影响

D. Dudek, Kazimierz Konieczny
{"title":"塑料和钢纤维加固对钢锚强度的影响","authors":"D. Dudek, Kazimierz Konieczny","doi":"10.22630/aspa.2021.20.1.4","DOIUrl":null,"url":null,"abstract":"Abstract The paper describes changes of strength of steel anchors depending on the diameter of the drill hole, the crack width and presence of plastic and steel fibres. Tests were carried out on C20/25 concrete bases with two specific fibre admixtures. Two types of anchors were selected for the tests: stud and sleeve anchors with M12 diameter, for their frequent application in construction. Steelbet 50/0.8 fibres affect the strength of the connections which use stud anchors, reducing the pullout resistance by ca. 10% in non-cracked C20/25 concrete. For cracked concrete with crack width of 0.30 mm and connections using stud anchors, no effect of using steel fibres was found, a 30% increase in strength was found for connections using stud anchors and the minimum drill hole diameter and a 20% reduction in strength for the maximum drill hole diameter, as compared to the minimum diameter. For sleeve anchors, reductions and an increase of 10% in strength were observed. The obtained results indicate a need to develop assessment criteria for effects of external factors in the form of steel fibre admixtures.","PeriodicalId":33811,"journal":{"name":"Acta Scientiarum Polonorum Architectura","volume":"65 1","pages":"31 - 38"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of Plastic and Steel Fibre Reinforcement on the Strength of Steel Anchors\",\"authors\":\"D. Dudek, Kazimierz Konieczny\",\"doi\":\"10.22630/aspa.2021.20.1.4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The paper describes changes of strength of steel anchors depending on the diameter of the drill hole, the crack width and presence of plastic and steel fibres. Tests were carried out on C20/25 concrete bases with two specific fibre admixtures. Two types of anchors were selected for the tests: stud and sleeve anchors with M12 diameter, for their frequent application in construction. Steelbet 50/0.8 fibres affect the strength of the connections which use stud anchors, reducing the pullout resistance by ca. 10% in non-cracked C20/25 concrete. For cracked concrete with crack width of 0.30 mm and connections using stud anchors, no effect of using steel fibres was found, a 30% increase in strength was found for connections using stud anchors and the minimum drill hole diameter and a 20% reduction in strength for the maximum drill hole diameter, as compared to the minimum diameter. For sleeve anchors, reductions and an increase of 10% in strength were observed. The obtained results indicate a need to develop assessment criteria for effects of external factors in the form of steel fibre admixtures.\",\"PeriodicalId\":33811,\"journal\":{\"name\":\"Acta Scientiarum Polonorum Architectura\",\"volume\":\"65 1\",\"pages\":\"31 - 38\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Scientiarum Polonorum Architectura\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22630/aspa.2021.20.1.4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Scientiarum Polonorum Architectura","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22630/aspa.2021.20.1.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要本文描述了钢锚强度随钻孔直径、裂缝宽度以及塑料和钢纤维存在的变化。在C20/25混凝土基层上进行了两种特定纤维掺合料的试验。试验选择了两种锚杆:直径为M12的螺柱锚杆和套筒锚杆,因为它们在施工中经常使用。Steelbet 50/0.8纤维会影响螺栓锚固连接的强度,在无裂缝的C20/25混凝土中降低约10%的拉拔阻力。对于裂缝宽度为0.30 mm的开裂混凝土和使用螺柱锚的连接,没有发现使用钢纤维的影响,使用螺柱锚和最小钻孔直径的连接强度增加了30%,与最小直径相比,最大钻孔直径的强度降低了20%。对于套筒锚,强度降低和增加了10%。所得结果表明,需要制定钢纤维外加剂形式的外部因素影响的评估标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of Plastic and Steel Fibre Reinforcement on the Strength of Steel Anchors
Abstract The paper describes changes of strength of steel anchors depending on the diameter of the drill hole, the crack width and presence of plastic and steel fibres. Tests were carried out on C20/25 concrete bases with two specific fibre admixtures. Two types of anchors were selected for the tests: stud and sleeve anchors with M12 diameter, for their frequent application in construction. Steelbet 50/0.8 fibres affect the strength of the connections which use stud anchors, reducing the pullout resistance by ca. 10% in non-cracked C20/25 concrete. For cracked concrete with crack width of 0.30 mm and connections using stud anchors, no effect of using steel fibres was found, a 30% increase in strength was found for connections using stud anchors and the minimum drill hole diameter and a 20% reduction in strength for the maximum drill hole diameter, as compared to the minimum diameter. For sleeve anchors, reductions and an increase of 10% in strength were observed. The obtained results indicate a need to develop assessment criteria for effects of external factors in the form of steel fibre admixtures.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
32
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信