{"title":"新型紫外光谱法测定原料药和刚果红制剂中l -谷胱甘肽含量的建立与验证","authors":"G. Gajeli, S. Kumbhar, G. Patel","doi":"10.52711/2231-5675.2022.00014","DOIUrl":null,"url":null,"abstract":"A novel UV-Spectroscopy method was developed and validated for the estimation of L-glutathione in bulk and dosage form with congo red. The wavelength at which L-glutathione and congo red mixture product showed maximum absorption at 568nm in distilled water. The developed method range was found to be10-90µg/ml. The developed method validated for linearity, precision, range, limit of detection, the limit of quantification, robustness, specificity, system suitability. The regression equation was found to be y = 0.0045x + 0.121 with correlation coefficient R² = 0.9983. The limit of detection and the quantification limit was 5.05 µg/ml and 15.32 µg/ml respectively. The developed method was found to be linear, precise, robust, economical for the evaluation of L-glutathione in bulk and dosage form.","PeriodicalId":8547,"journal":{"name":"Asian Journal of Pharmaceutical Analysis","volume":"13 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and Validation of Novel UV Spectroscopy Method for the Estimation of L-Glutathione in Bulk and Formulation with Congo Red\",\"authors\":\"G. Gajeli, S. Kumbhar, G. Patel\",\"doi\":\"10.52711/2231-5675.2022.00014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel UV-Spectroscopy method was developed and validated for the estimation of L-glutathione in bulk and dosage form with congo red. The wavelength at which L-glutathione and congo red mixture product showed maximum absorption at 568nm in distilled water. The developed method range was found to be10-90µg/ml. The developed method validated for linearity, precision, range, limit of detection, the limit of quantification, robustness, specificity, system suitability. The regression equation was found to be y = 0.0045x + 0.121 with correlation coefficient R² = 0.9983. The limit of detection and the quantification limit was 5.05 µg/ml and 15.32 µg/ml respectively. The developed method was found to be linear, precise, robust, economical for the evaluation of L-glutathione in bulk and dosage form.\",\"PeriodicalId\":8547,\"journal\":{\"name\":\"Asian Journal of Pharmaceutical Analysis\",\"volume\":\"13 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Pharmaceutical Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52711/2231-5675.2022.00014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Pharmaceutical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/2231-5675.2022.00014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development and Validation of Novel UV Spectroscopy Method for the Estimation of L-Glutathione in Bulk and Formulation with Congo Red
A novel UV-Spectroscopy method was developed and validated for the estimation of L-glutathione in bulk and dosage form with congo red. The wavelength at which L-glutathione and congo red mixture product showed maximum absorption at 568nm in distilled water. The developed method range was found to be10-90µg/ml. The developed method validated for linearity, precision, range, limit of detection, the limit of quantification, robustness, specificity, system suitability. The regression equation was found to be y = 0.0045x + 0.121 with correlation coefficient R² = 0.9983. The limit of detection and the quantification limit was 5.05 µg/ml and 15.32 µg/ml respectively. The developed method was found to be linear, precise, robust, economical for the evaluation of L-glutathione in bulk and dosage form.