Baolei Xu, Yunfa Fu, G. Shi, Xuxian Yin, Zhidong Wang, Hongyi Li
{"title":"基于特征离散和优化的基于fnir的脑机接口分类改进","authors":"Baolei Xu, Yunfa Fu, G. Shi, Xuxian Yin, Zhidong Wang, Hongyi Li","doi":"10.4172/1662-100X.1000119","DOIUrl":null,"url":null,"abstract":"In this paper, we present a signal discretization and feature selection method to improve classification accuracy for fNIRS based brain computer interface (BCI) system, which can classifiy right hand clench force motor imagery and clench speed motor imagery at an accuracy of 69%-81% through 5 fold cross validation in 6 subjects. Difference between oxyhemoglobin and deoxyhemoglobin (we abbreviate this difference as HbD) is proposed as a new feature type and shows outstanding performance in some subjects. Linear kernal support vector machine (SVM) classification between clench force motor imagery and clench speed motor imagery using four concentration feature types (oxyhemoglobin, deoxyhemoglobin, totalhemoglobin, and HbD) is implemented. Our results demonstrate that feature discretization using Chi2 algorighm and feature optimization using ‘MIFS’ (Mutual Information Feature Selection) criterion can improve the classification accuracy by more than 35%. Except total hemoglobin, all the other three feature types can be used as the optimum feature for different subjects. The results of this paper can also be used in online BCI applications.","PeriodicalId":15198,"journal":{"name":"Journal of Biomimetics, Biomaterials and Tissue Engineering","volume":"108 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Improving Classification by Feature Discretization and Optimization for fNIRS-based BCI\",\"authors\":\"Baolei Xu, Yunfa Fu, G. Shi, Xuxian Yin, Zhidong Wang, Hongyi Li\",\"doi\":\"10.4172/1662-100X.1000119\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we present a signal discretization and feature selection method to improve classification accuracy for fNIRS based brain computer interface (BCI) system, which can classifiy right hand clench force motor imagery and clench speed motor imagery at an accuracy of 69%-81% through 5 fold cross validation in 6 subjects. Difference between oxyhemoglobin and deoxyhemoglobin (we abbreviate this difference as HbD) is proposed as a new feature type and shows outstanding performance in some subjects. Linear kernal support vector machine (SVM) classification between clench force motor imagery and clench speed motor imagery using four concentration feature types (oxyhemoglobin, deoxyhemoglobin, totalhemoglobin, and HbD) is implemented. Our results demonstrate that feature discretization using Chi2 algorighm and feature optimization using ‘MIFS’ (Mutual Information Feature Selection) criterion can improve the classification accuracy by more than 35%. Except total hemoglobin, all the other three feature types can be used as the optimum feature for different subjects. The results of this paper can also be used in online BCI applications.\",\"PeriodicalId\":15198,\"journal\":{\"name\":\"Journal of Biomimetics, Biomaterials and Tissue Engineering\",\"volume\":\"108 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomimetics, Biomaterials and Tissue Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/1662-100X.1000119\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomimetics, Biomaterials and Tissue Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/1662-100X.1000119","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improving Classification by Feature Discretization and Optimization for fNIRS-based BCI
In this paper, we present a signal discretization and feature selection method to improve classification accuracy for fNIRS based brain computer interface (BCI) system, which can classifiy right hand clench force motor imagery and clench speed motor imagery at an accuracy of 69%-81% through 5 fold cross validation in 6 subjects. Difference between oxyhemoglobin and deoxyhemoglobin (we abbreviate this difference as HbD) is proposed as a new feature type and shows outstanding performance in some subjects. Linear kernal support vector machine (SVM) classification between clench force motor imagery and clench speed motor imagery using four concentration feature types (oxyhemoglobin, deoxyhemoglobin, totalhemoglobin, and HbD) is implemented. Our results demonstrate that feature discretization using Chi2 algorighm and feature optimization using ‘MIFS’ (Mutual Information Feature Selection) criterion can improve the classification accuracy by more than 35%. Except total hemoglobin, all the other three feature types can be used as the optimum feature for different subjects. The results of this paper can also be used in online BCI applications.