{"title":"地铁车站顶管井及管接头防水试验研究","authors":"Zhi Qiang Wang, Z. Lei","doi":"10.4028/p-73d553","DOIUrl":null,"url":null,"abstract":"Through the indoor waterproof test, the water pressure resistance performance of the waterproof system formed by setting embedded grouting pipe in the middle of double water swelling sealants was studied to ensure that the station pipe joint could meet the operation requirements. The results show that there must be enough distance between the outside sealant and the edge of the pouring concrete, otherwise the new and old concretes cannot be poured tightly; after swelling, the water pressure resistance of sealants is improved in the range of 0-0.55 MPa, with individual differences; the two kinds of slurries have obvious influence on the improvement of water pressure resistance, but the improvement effect of waterborne epoxy slurry is better than that of polyurethane slurry.","PeriodicalId":7184,"journal":{"name":"Advanced Engineering Forum","volume":"78 1","pages":"1 - 15"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Study on Waterproofing of Pipe Jacking Shaft and Pipe Joint in Metro Station\",\"authors\":\"Zhi Qiang Wang, Z. Lei\",\"doi\":\"10.4028/p-73d553\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Through the indoor waterproof test, the water pressure resistance performance of the waterproof system formed by setting embedded grouting pipe in the middle of double water swelling sealants was studied to ensure that the station pipe joint could meet the operation requirements. The results show that there must be enough distance between the outside sealant and the edge of the pouring concrete, otherwise the new and old concretes cannot be poured tightly; after swelling, the water pressure resistance of sealants is improved in the range of 0-0.55 MPa, with individual differences; the two kinds of slurries have obvious influence on the improvement of water pressure resistance, but the improvement effect of waterborne epoxy slurry is better than that of polyurethane slurry.\",\"PeriodicalId\":7184,\"journal\":{\"name\":\"Advanced Engineering Forum\",\"volume\":\"78 1\",\"pages\":\"1 - 15\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Engineering Forum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4028/p-73d553\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Engineering Forum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/p-73d553","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

通过室内防水试验,研究了在双水膨胀密封胶中间设置预埋注浆管形成的防水体系的抗水压性能,确保站管接头满足使用要求。结果表明:外密封胶与浇筑混凝土边缘之间必须有足够的距离,否则新老混凝土不能浇筑紧密;溶胀后密封胶的耐水压性能在0 ~ 0.55 MPa范围内有所提高,存在个体差异;两种浆料对提高耐水压性能均有明显影响,但水性环氧浆料的改善效果优于聚氨酯浆料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental Study on Waterproofing of Pipe Jacking Shaft and Pipe Joint in Metro Station
Through the indoor waterproof test, the water pressure resistance performance of the waterproof system formed by setting embedded grouting pipe in the middle of double water swelling sealants was studied to ensure that the station pipe joint could meet the operation requirements. The results show that there must be enough distance between the outside sealant and the edge of the pouring concrete, otherwise the new and old concretes cannot be poured tightly; after swelling, the water pressure resistance of sealants is improved in the range of 0-0.55 MPa, with individual differences; the two kinds of slurries have obvious influence on the improvement of water pressure resistance, but the improvement effect of waterborne epoxy slurry is better than that of polyurethane slurry.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信