M. Yen, Fang-Yu Zhou, Wen-Ling Chang, Hsiao-Chin Chen
{"title":"毫米波接收器前端无创血糖测量","authors":"M. Yen, Fang-Yu Zhou, Wen-Ling Chang, Hsiao-Chin Chen","doi":"10.1109/ISPACS48206.2019.8986240","DOIUrl":null,"url":null,"abstract":"A millimeter wave (MMW) receiver front-end is designed and implemented using 90-nm CMOS technology for noninvasive glucose measurement. The LNA achieves the power gain of 19.43 dB at 29 GHz and the minimum noise figure of 6 dB at 29 GHz. The mixer performs frequency translation to convert the signals at 28–30 GHz to 10 MHz. The receiver front-end achieves the conversion gain of 14 dB and the PldB of −23 dBm. The VCO delivers the frequency band of 28–30 GHz while achieving the FOM of −182.3 dBc/Hz.","PeriodicalId":6765,"journal":{"name":"2019 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS)","volume":"78 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"MMW Receiver Front-End for Noninvasive Glucose Measurement\",\"authors\":\"M. Yen, Fang-Yu Zhou, Wen-Ling Chang, Hsiao-Chin Chen\",\"doi\":\"10.1109/ISPACS48206.2019.8986240\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A millimeter wave (MMW) receiver front-end is designed and implemented using 90-nm CMOS technology for noninvasive glucose measurement. The LNA achieves the power gain of 19.43 dB at 29 GHz and the minimum noise figure of 6 dB at 29 GHz. The mixer performs frequency translation to convert the signals at 28–30 GHz to 10 MHz. The receiver front-end achieves the conversion gain of 14 dB and the PldB of −23 dBm. The VCO delivers the frequency band of 28–30 GHz while achieving the FOM of −182.3 dBc/Hz.\",\"PeriodicalId\":6765,\"journal\":{\"name\":\"2019 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS)\",\"volume\":\"78 1\",\"pages\":\"1-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISPACS48206.2019.8986240\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPACS48206.2019.8986240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
MMW Receiver Front-End for Noninvasive Glucose Measurement
A millimeter wave (MMW) receiver front-end is designed and implemented using 90-nm CMOS technology for noninvasive glucose measurement. The LNA achieves the power gain of 19.43 dB at 29 GHz and the minimum noise figure of 6 dB at 29 GHz. The mixer performs frequency translation to convert the signals at 28–30 GHz to 10 MHz. The receiver front-end achieves the conversion gain of 14 dB and the PldB of −23 dBm. The VCO delivers the frequency band of 28–30 GHz while achieving the FOM of −182.3 dBc/Hz.