不同水胶比和纤维含量对PVA-ECC材料流动性和力学性能的影响

IF 1 4区 工程技术 Q3 ENGINEERING, MULTIDISCIPLINARY
Qin Xin, Ruyu Gao, Peng-Cheng Shao, LV Wenbo, Hao Wei
{"title":"不同水胶比和纤维含量对PVA-ECC材料流动性和力学性能的影响","authors":"Qin Xin, Ruyu Gao, Peng-Cheng Shao, LV Wenbo, Hao Wei","doi":"10.17559/tv-20230426000576","DOIUrl":null,"url":null,"abstract":": With the development of fiber-reinforced cement composites, the diversity and complexity of application scenarios require enhanced strength and ductility and tough materials in practical engineering. To explore the effects of different water-binder ratios and fiber contents on the fluidity, bending resistance, tensile properties, fracture toughness, and fracture behavior of polyvinyl alcohol (PVA) fiber cement composites, several groups of high ductility test blocks (PVA-engineering cementitious composites (ECC)) with different mixing ratios were designed in this study. Based on the expansion degree, the mechanical experimental data, and the electron microscopy scanning image results, K -value analysis was performed on the strain hardening strength criterion. The effect of the water–binder ratio and the fiber dosing on the PVA-ECC material was determined. Results show that the greater the water-binder ratio is, the better the fluidity of the ECC matrix is. In the same cement system and at the same water-binder ratio, the fluidity of the ECC paste gradually deteriorates with the increase of the fiber content. The water-binder ratio significantly affects the flexural tensile strength of the composite. The flexural and tensile strengths of the PVA-ECC gradually increase as the water-binder ratio decreases, but the ductility gradually decreases. The water-binder ratio of the substrate directly influences the damage behavior of the fibers within the substrate. With the gradual increase of the water-binder ratio, the fiber at the crack interface gradually changes from pull-out morphology to fracture morphology. The strain capacity and the multi-crack cracking performance decrease. To achieve improved working performance in the actual project, the matrix water-binder ratio should be controlled at approximately 0.45, and the PVA fiber dose of 1.7% is optimal. This study can provide a good reference for","PeriodicalId":49443,"journal":{"name":"Tehnicki Vjesnik-Technical Gazette","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Different Water-Binder Ratios and Fiber Contents on the Fluidity and Mechanical Properties of PVA-ECC Materials\",\"authors\":\"Qin Xin, Ruyu Gao, Peng-Cheng Shao, LV Wenbo, Hao Wei\",\"doi\":\"10.17559/tv-20230426000576\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": With the development of fiber-reinforced cement composites, the diversity and complexity of application scenarios require enhanced strength and ductility and tough materials in practical engineering. To explore the effects of different water-binder ratios and fiber contents on the fluidity, bending resistance, tensile properties, fracture toughness, and fracture behavior of polyvinyl alcohol (PVA) fiber cement composites, several groups of high ductility test blocks (PVA-engineering cementitious composites (ECC)) with different mixing ratios were designed in this study. Based on the expansion degree, the mechanical experimental data, and the electron microscopy scanning image results, K -value analysis was performed on the strain hardening strength criterion. The effect of the water–binder ratio and the fiber dosing on the PVA-ECC material was determined. Results show that the greater the water-binder ratio is, the better the fluidity of the ECC matrix is. In the same cement system and at the same water-binder ratio, the fluidity of the ECC paste gradually deteriorates with the increase of the fiber content. The water-binder ratio significantly affects the flexural tensile strength of the composite. The flexural and tensile strengths of the PVA-ECC gradually increase as the water-binder ratio decreases, but the ductility gradually decreases. The water-binder ratio of the substrate directly influences the damage behavior of the fibers within the substrate. With the gradual increase of the water-binder ratio, the fiber at the crack interface gradually changes from pull-out morphology to fracture morphology. The strain capacity and the multi-crack cracking performance decrease. To achieve improved working performance in the actual project, the matrix water-binder ratio should be controlled at approximately 0.45, and the PVA fiber dose of 1.7% is optimal. This study can provide a good reference for\",\"PeriodicalId\":49443,\"journal\":{\"name\":\"Tehnicki Vjesnik-Technical Gazette\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tehnicki Vjesnik-Technical Gazette\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.17559/tv-20230426000576\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tehnicki Vjesnik-Technical Gazette","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.17559/tv-20230426000576","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

随着纤维增强水泥复合材料的发展,应用场景的多样性和复杂性要求在实际工程中增强材料的强度和延性,增强材料的韧性。为探讨不同水胶比和纤维含量对聚乙烯醇(PVA)纤维水泥复合材料流动性、抗弯性能、拉伸性能、断裂韧性和断裂行为的影响,设计了多组不同掺比的高延性试验块(PVA-工程胶凝复合材料(ECC))。根据膨胀程度、力学实验数据和电镜扫描图像结果,对应变硬化强度准则进行K值分析。研究了水胶比和纤维用量对聚乙烯醇- ecc材料性能的影响。结果表明,水胶比越大,ECC基质的流动性越好。在相同水泥体系、相同水胶比下,随着纤维含量的增加,ECC膏体的流动性逐渐变差。水胶比对复合材料的抗弯拉伸强度有显著影响。随着水胶比的减小,PVA-ECC的抗弯强度和抗拉强度逐渐增大,但延性逐渐降低。基材的水胶比直接影响基材内纤维的损伤行为。随着水胶比的逐渐增大,裂纹界面处的纤维逐渐由拉出形态转变为断裂形态。应变能力和多裂纹开裂性能下降。为了在实际工程中获得更好的工作性能,应将基体水胶比控制在0.45左右,以1.7%的PVA纤维用量为最佳。本文的研究可以为我国医药行业的发展提供很好的参考
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Different Water-Binder Ratios and Fiber Contents on the Fluidity and Mechanical Properties of PVA-ECC Materials
: With the development of fiber-reinforced cement composites, the diversity and complexity of application scenarios require enhanced strength and ductility and tough materials in practical engineering. To explore the effects of different water-binder ratios and fiber contents on the fluidity, bending resistance, tensile properties, fracture toughness, and fracture behavior of polyvinyl alcohol (PVA) fiber cement composites, several groups of high ductility test blocks (PVA-engineering cementitious composites (ECC)) with different mixing ratios were designed in this study. Based on the expansion degree, the mechanical experimental data, and the electron microscopy scanning image results, K -value analysis was performed on the strain hardening strength criterion. The effect of the water–binder ratio and the fiber dosing on the PVA-ECC material was determined. Results show that the greater the water-binder ratio is, the better the fluidity of the ECC matrix is. In the same cement system and at the same water-binder ratio, the fluidity of the ECC paste gradually deteriorates with the increase of the fiber content. The water-binder ratio significantly affects the flexural tensile strength of the composite. The flexural and tensile strengths of the PVA-ECC gradually increase as the water-binder ratio decreases, but the ductility gradually decreases. The water-binder ratio of the substrate directly influences the damage behavior of the fibers within the substrate. With the gradual increase of the water-binder ratio, the fiber at the crack interface gradually changes from pull-out morphology to fracture morphology. The strain capacity and the multi-crack cracking performance decrease. To achieve improved working performance in the actual project, the matrix water-binder ratio should be controlled at approximately 0.45, and the PVA fiber dose of 1.7% is optimal. This study can provide a good reference for
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Tehnicki Vjesnik-Technical Gazette
Tehnicki Vjesnik-Technical Gazette ENGINEERING, MULTIDISCIPLINARY-
CiteScore
1.90
自引率
11.10%
发文量
270
审稿时长
12.6 months
期刊介绍: The journal TEHNIČKI VJESNIK - TECHNICAL GAZETTE publishes scientific and professional papers in the area of technical sciences (mostly from mechanical, electrical and civil engineering, and also from their boundary areas). All articles have undergone peer review and upon acceptance are permanently free of all restrictions on access, for everyone to read and download. For all articles authors will be asked to pay a publication fee prior to the article appearing in the journal. However, this fee only to be paid after the article has been positively reviewed and accepted for publishing. All details can be seen at http://www.tehnicki-vjesnik.com/web/public/page First year of publication: 1994 Frequency (annually): 6
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信