基于模糊稳定器的多机电力系统性能评价

M. Jalaluddin, H. .. Saikumar, Bansilal
{"title":"基于模糊稳定器的多机电力系统性能评价","authors":"M. Jalaluddin, H. .. Saikumar, Bansilal","doi":"10.1109/TAPENERGY.2015.7229614","DOIUrl":null,"url":null,"abstract":"Power system operates under secure state. Any disturbance in terms of fault or major load change introduces oscillations in the power system. These oscillations cause stability problems, if not damped in short span of time. In a multi machine power system the rotor swing between generators makes the problem more complicated. In this paper Fuzzy Logic based Power System Stabilizer (FLPSS) is designed to damp the low frequency oscillations arising out of small and large disturbances in multi machine system. FLPSS is designed with speed deviation and rotor acceleration as input signals. The novelty about the work reported in this paper is that nine linguistic variables are considered to design the FLPSS. A four machine, two-area system is considered to validate the design of the proposed FLPSS. The superiority of the FLPSS is demonstrated by comparing its performance with that of a Conventional PSS (CPSS) by carrying out nonlinear simulation on the multi machine.","PeriodicalId":6552,"journal":{"name":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","volume":"54 1","pages":"182-186"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Performance evaluation of multi machine power system with Fuzzy based Power System Stabilizer\",\"authors\":\"M. Jalaluddin, H. .. Saikumar, Bansilal\",\"doi\":\"10.1109/TAPENERGY.2015.7229614\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power system operates under secure state. Any disturbance in terms of fault or major load change introduces oscillations in the power system. These oscillations cause stability problems, if not damped in short span of time. In a multi machine power system the rotor swing between generators makes the problem more complicated. In this paper Fuzzy Logic based Power System Stabilizer (FLPSS) is designed to damp the low frequency oscillations arising out of small and large disturbances in multi machine system. FLPSS is designed with speed deviation and rotor acceleration as input signals. The novelty about the work reported in this paper is that nine linguistic variables are considered to design the FLPSS. A four machine, two-area system is considered to validate the design of the proposed FLPSS. The superiority of the FLPSS is demonstrated by comparing its performance with that of a Conventional PSS (CPSS) by carrying out nonlinear simulation on the multi machine.\",\"PeriodicalId\":6552,\"journal\":{\"name\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"volume\":\"54 1\",\"pages\":\"182-186\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAPENERGY.2015.7229614\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAPENERGY.2015.7229614","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

电力系统在安全状态下运行。任何由故障或主要负荷变化引起的扰动都会引起电力系统的振荡。这些振荡如果不能在短时间内得到抑制,就会引起稳定性问题。在多机电力系统中,发电机之间的转子摆动使问题更加复杂。本文设计了基于模糊逻辑的电力系统稳定器(FLPSS),以抑制多机系统中因大大小小的干扰而产生的低频振荡。FLPSS以转速偏差和转子加速度作为输入信号。本文工作的新颖之处在于,在设计FLPSS时考虑了9个语言变量。以四机两区系统为例,验证了FLPSS的设计。通过多机非线性仿真,将FLPSS与传统PSS (CPSS)的性能进行了比较,证明了FLPSS的优越性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance evaluation of multi machine power system with Fuzzy based Power System Stabilizer
Power system operates under secure state. Any disturbance in terms of fault or major load change introduces oscillations in the power system. These oscillations cause stability problems, if not damped in short span of time. In a multi machine power system the rotor swing between generators makes the problem more complicated. In this paper Fuzzy Logic based Power System Stabilizer (FLPSS) is designed to damp the low frequency oscillations arising out of small and large disturbances in multi machine system. FLPSS is designed with speed deviation and rotor acceleration as input signals. The novelty about the work reported in this paper is that nine linguistic variables are considered to design the FLPSS. A four machine, two-area system is considered to validate the design of the proposed FLPSS. The superiority of the FLPSS is demonstrated by comparing its performance with that of a Conventional PSS (CPSS) by carrying out nonlinear simulation on the multi machine.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信