电动阀诊断的专家神经系统

E. Trykov, I. Trykova, Konstantin I. Kotsoyev
{"title":"电动阀诊断的专家神经系统","authors":"E. Trykov, I. Trykova, Konstantin I. Kotsoyev","doi":"10.3897/nucet.7.78339","DOIUrl":null,"url":null,"abstract":"Trouble-free operation of motor-driven valves (MDV) is one of the key factors behind the operating safety of NPPs. As critical components, MDVs are a part of a safety system and a safety-related system. This imposes the highest possible requirements on the MDV reliability.\n MDVs are the most numerous category of the NPP components. Depending on design, one power unit contains 1500 to 3000 motor-driven valves alone. It follows from an analysis of the NPP failures that many of these are caused by failed motor-driven valves of safety and safety-related systems.\n The paper presents a description of an automated system for diagnostics of shutoff and control MDVs used in the NPP pipelines. The developed diagnostic algorithms make it possible to take into account the variability of the MDV technical parameters, while taking into account, at the same time, rated restrictions on diagnostic parameters, if any.","PeriodicalId":100969,"journal":{"name":"Nuclear Energy and Technology","volume":"38 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An expert neural system for diagnostics of motor-driven valves\",\"authors\":\"E. Trykov, I. Trykova, Konstantin I. Kotsoyev\",\"doi\":\"10.3897/nucet.7.78339\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Trouble-free operation of motor-driven valves (MDV) is one of the key factors behind the operating safety of NPPs. As critical components, MDVs are a part of a safety system and a safety-related system. This imposes the highest possible requirements on the MDV reliability.\\n MDVs are the most numerous category of the NPP components. Depending on design, one power unit contains 1500 to 3000 motor-driven valves alone. It follows from an analysis of the NPP failures that many of these are caused by failed motor-driven valves of safety and safety-related systems.\\n The paper presents a description of an automated system for diagnostics of shutoff and control MDVs used in the NPP pipelines. The developed diagnostic algorithms make it possible to take into account the variability of the MDV technical parameters, while taking into account, at the same time, rated restrictions on diagnostic parameters, if any.\",\"PeriodicalId\":100969,\"journal\":{\"name\":\"Nuclear Energy and Technology\",\"volume\":\"38 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Energy and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3897/nucet.7.78339\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Energy and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3897/nucet.7.78339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电动阀的无故障运行是核电站安全运行的关键因素之一。作为关键部件,mdv是安全系统和安全相关系统的一部分。这对MDV的可靠性提出了最高的要求。mdv是NPP成分中数量最多的一类。根据设计的不同,一个动力单元仅包含1500到3000个电机驱动阀门。根据对核电站故障的分析,其中许多故障是由电机驱动的安全阀门和安全相关系统故障引起的。本文介绍了一种用于核电厂管道关闭诊断和控制的自动化系统。所开发的诊断算法可以考虑MDV技术参数的可变性,同时考虑到对诊断参数的额定限制(如果有的话)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An expert neural system for diagnostics of motor-driven valves
Trouble-free operation of motor-driven valves (MDV) is one of the key factors behind the operating safety of NPPs. As critical components, MDVs are a part of a safety system and a safety-related system. This imposes the highest possible requirements on the MDV reliability. MDVs are the most numerous category of the NPP components. Depending on design, one power unit contains 1500 to 3000 motor-driven valves alone. It follows from an analysis of the NPP failures that many of these are caused by failed motor-driven valves of safety and safety-related systems. The paper presents a description of an automated system for diagnostics of shutoff and control MDVs used in the NPP pipelines. The developed diagnostic algorithms make it possible to take into account the variability of the MDV technical parameters, while taking into account, at the same time, rated restrictions on diagnostic parameters, if any.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信