{"title":"大型罐底板腐蚀的浸没声定位方法","authors":"Zhang Ying, Zhang Xiao, Zhu Zidong, Dang Na, C. Xiaolong","doi":"10.16265/J.CNKI.ISSN1003-3033.2020.03.006","DOIUrl":null,"url":null,"abstract":"In order to avoid detection dead zone in corrosion detection of large ̄scale storage tank floorꎬ an immersion acoustic method is proposedꎬ of which locating corrosion sound source is a key. Based on a passive source localization algorithm featuring time delay estimation and considering characteristics of immersed acoustic detection of tank floorꎬ a mobile planar five ̄element cross array acoustic method was applied to simulate positioning of bottom plate and verify the test. The results show that this method meets the requirement of corrosion detection in accuracy of direction finding and distance measurement. Direction finding accuracy is not affected by sound source angle φ and distance r while distance accuracy is only positively related to r and independent of φ. With the fitting relationship between relative error of distance and r obtained from experimentꎬ the maximum effective radius of immersed acoustic detecting unit can be 中 国 安 全 科 学 学 报 China Safety Science Journal 第30卷 2020年 determined.","PeriodicalId":9976,"journal":{"name":"中国安全科学学报","volume":"95 1","pages":"35"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Immersion acoustic positioning method of corrosion for large tank bottom plate\",\"authors\":\"Zhang Ying, Zhang Xiao, Zhu Zidong, Dang Na, C. Xiaolong\",\"doi\":\"10.16265/J.CNKI.ISSN1003-3033.2020.03.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to avoid detection dead zone in corrosion detection of large ̄scale storage tank floorꎬ an immersion acoustic method is proposedꎬ of which locating corrosion sound source is a key. Based on a passive source localization algorithm featuring time delay estimation and considering characteristics of immersed acoustic detection of tank floorꎬ a mobile planar five ̄element cross array acoustic method was applied to simulate positioning of bottom plate and verify the test. The results show that this method meets the requirement of corrosion detection in accuracy of direction finding and distance measurement. Direction finding accuracy is not affected by sound source angle φ and distance r while distance accuracy is only positively related to r and independent of φ. With the fitting relationship between relative error of distance and r obtained from experimentꎬ the maximum effective radius of immersed acoustic detecting unit can be 中 国 安 全 科 学 学 报 China Safety Science Journal 第30卷 2020年 determined.\",\"PeriodicalId\":9976,\"journal\":{\"name\":\"中国安全科学学报\",\"volume\":\"95 1\",\"pages\":\"35\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国安全科学学报\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.16265/J.CNKI.ISSN1003-3033.2020.03.006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国安全科学学报","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.16265/J.CNKI.ISSN1003-3033.2020.03.006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Immersion acoustic positioning method of corrosion for large tank bottom plate
In order to avoid detection dead zone in corrosion detection of large ̄scale storage tank floorꎬ an immersion acoustic method is proposedꎬ of which locating corrosion sound source is a key. Based on a passive source localization algorithm featuring time delay estimation and considering characteristics of immersed acoustic detection of tank floorꎬ a mobile planar five ̄element cross array acoustic method was applied to simulate positioning of bottom plate and verify the test. The results show that this method meets the requirement of corrosion detection in accuracy of direction finding and distance measurement. Direction finding accuracy is not affected by sound source angle φ and distance r while distance accuracy is only positively related to r and independent of φ. With the fitting relationship between relative error of distance and r obtained from experimentꎬ the maximum effective radius of immersed acoustic detecting unit can be 中 国 安 全 科 学 学 报 China Safety Science Journal 第30卷 2020年 determined.
期刊介绍:
China Safety Science Journal is administered by China Association for Science and Technology and sponsored by China Occupational Safety and Health Association (formerly China Society of Science and Technology for Labor Protection). It was first published on January 20, 1991 and was approved for public distribution at home and abroad.
China Safety Science Journal (CN 11-2865/X ISSN 1003-3033 CODEN ZAKXAM) is a monthly magazine, 12 issues a year, large 16 folo, the domestic price of each book is 40.00 yuan, the annual price is 480.00 yuan. Mailing code 82-454.
Honors:
Scopus database includes journals in the field of safety science of high-quality scientific journals classification catalog T1 level
National Chinese core journals China Science and technology core journals CSCD journals
The United States "Chemical Abstracts" search included the United States "Cambridge Scientific Abstracts: Materials Information" search included