K-200的混凝土特性采用了2%的重量,比例为L/D

T. Mulyono
{"title":"K-200的混凝土特性采用了2%的重量,比例为L/D","authors":"T. Mulyono","doi":"10.32497/wahanats.v27i1.3675","DOIUrl":null,"url":null,"abstract":"This research aims to determine the characteristics of K-200 concrete according to Permen PUPR No. 28/PRT/M/2016 article B.06, using steel fibers (bendrat wire) with 2% steel fiber by weight of concrete volume and variations in the L/D ratio through laboratory tests. The total population is 12 specimens with a sample of compressive strength 5 specimens and split tensile strength 4 specimens for each treatment which is a random sample, i.e.: A (reference concrete); B, C, D, and E for concrete with 2% fiber and L/D ratio of 50; 62.5; 75 and 87.5. The test results of concrete materials meet the SNI. The significance level of 0.05 indicates that the test data are normal distribution and uniform. The hypothesis result shows that there is a difference between the reference concrete and the concrete fiber with variations L/D. The unit weight of concrete between the reference concrete and the concrete with variations of L/D is slightly different. The slump value decreases with the L/D ratio. Characteristics of the concrete increase up to L/D 75. Based on the design of K-200 concrete per-as Permen PUPR No. 28/PRT/M/2016 article B.06, compressive strength, split tensile strength, and flexural strength for reference concrete are 17,316 MPa, 2,317 MPa, and 3,083 MPa, greater than 35,9%, 43,8%, and 28,7% of design. Fiber concrete with variation of L/D, compared with reference concrete is greater than 32,7%, 39,7% and 26,2%.","PeriodicalId":34836,"journal":{"name":"Prokons","volume":"27 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"KARAKTERISTIK BETON MUTU K-200 MENGGUNAKAN SERAT 2% BERAT VOLUME DENGAN VARIASI RASIO L/D\",\"authors\":\"T. Mulyono\",\"doi\":\"10.32497/wahanats.v27i1.3675\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research aims to determine the characteristics of K-200 concrete according to Permen PUPR No. 28/PRT/M/2016 article B.06, using steel fibers (bendrat wire) with 2% steel fiber by weight of concrete volume and variations in the L/D ratio through laboratory tests. The total population is 12 specimens with a sample of compressive strength 5 specimens and split tensile strength 4 specimens for each treatment which is a random sample, i.e.: A (reference concrete); B, C, D, and E for concrete with 2% fiber and L/D ratio of 50; 62.5; 75 and 87.5. The test results of concrete materials meet the SNI. The significance level of 0.05 indicates that the test data are normal distribution and uniform. The hypothesis result shows that there is a difference between the reference concrete and the concrete fiber with variations L/D. The unit weight of concrete between the reference concrete and the concrete with variations of L/D is slightly different. The slump value decreases with the L/D ratio. Characteristics of the concrete increase up to L/D 75. Based on the design of K-200 concrete per-as Permen PUPR No. 28/PRT/M/2016 article B.06, compressive strength, split tensile strength, and flexural strength for reference concrete are 17,316 MPa, 2,317 MPa, and 3,083 MPa, greater than 35,9%, 43,8%, and 28,7% of design. Fiber concrete with variation of L/D, compared with reference concrete is greater than 32,7%, 39,7% and 26,2%.\",\"PeriodicalId\":34836,\"journal\":{\"name\":\"Prokons\",\"volume\":\"27 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Prokons\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32497/wahanats.v27i1.3675\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prokons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32497/wahanats.v27i1.3675","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在根据Permen PUPR No. 28/PRT/M/2016文章B.06确定K-200混凝土的特性,通过实验室测试,使用钢纤维(弯丝)占混凝土体积重量的2%,L/D比的变化。总体为12个试件,每个处理的抗压强度为5个试件,劈裂抗拉强度为4个试件,为随机试样,即:a(参考混凝土);B、C、D、E为纤维含量为2%、L/D比为50的混凝土;62.5;75和87.5。混凝土材料的试验结果满足SNI要求。显著性水平为0.05表示检验数据呈正态分布且均匀。假设结果表明,随L/D的变化,参考混凝土与混凝土纤维之间存在差异。参考混凝土和随L/D变化的混凝土的单位重量略有不同。坍落度随L/D比减小。混凝土的特性提高到L/D 75。根据Permen PUPR No. 28/PRT/M/2016 B.06条款K-200混凝土设计,参考混凝土的抗压强度、劈裂抗拉强度、抗弯强度分别为17316 MPa、2317 MPa、3083 MPa,分别大于设计值的35.9%、43.8%、28.7%。纤维混凝土随L/D的变化,与参考混凝土相比分别大于32.7%、39.7%和26.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
KARAKTERISTIK BETON MUTU K-200 MENGGUNAKAN SERAT 2% BERAT VOLUME DENGAN VARIASI RASIO L/D
This research aims to determine the characteristics of K-200 concrete according to Permen PUPR No. 28/PRT/M/2016 article B.06, using steel fibers (bendrat wire) with 2% steel fiber by weight of concrete volume and variations in the L/D ratio through laboratory tests. The total population is 12 specimens with a sample of compressive strength 5 specimens and split tensile strength 4 specimens for each treatment which is a random sample, i.e.: A (reference concrete); B, C, D, and E for concrete with 2% fiber and L/D ratio of 50; 62.5; 75 and 87.5. The test results of concrete materials meet the SNI. The significance level of 0.05 indicates that the test data are normal distribution and uniform. The hypothesis result shows that there is a difference between the reference concrete and the concrete fiber with variations L/D. The unit weight of concrete between the reference concrete and the concrete with variations of L/D is slightly different. The slump value decreases with the L/D ratio. Characteristics of the concrete increase up to L/D 75. Based on the design of K-200 concrete per-as Permen PUPR No. 28/PRT/M/2016 article B.06, compressive strength, split tensile strength, and flexural strength for reference concrete are 17,316 MPa, 2,317 MPa, and 3,083 MPa, greater than 35,9%, 43,8%, and 28,7% of design. Fiber concrete with variation of L/D, compared with reference concrete is greater than 32,7%, 39,7% and 26,2%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
6
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信