使用kinect传感器测量颈椎运动。

Xiaolong Ma, Guanghua Xu, Min Li, Jun Xie, Longting Chen, Wei Pei
{"title":"使用kinect传感器测量颈椎运动。","authors":"Xiaolong Ma, Guanghua Xu, Min Li, Jun Xie, Longting Chen, Wei Pei","doi":"10.1109/EMBC.2015.7318966","DOIUrl":null,"url":null,"abstract":"The incidence of cervical vertebra spondylosis is increasing with the pace of life while there is no high-efficient measurement method. This study proposed a non-contact, high-efficient, and high-precisionmethod measuring the cervical vertebra activities which obtains the cervical vertebra activities by combining the function of skeletal tracking and face tracking. A comparison study between the proposed and traditional methods has been conducted here. Statistics shows that the efficiency of the proposed measurement method at least is 6 times faster than modified square shaped goniometers that is the represent of traditional measurement, and it's angular error in average is 0.35°. Moreover, the proposed measuring method has been tested in hospital clinical environment and the results show that the proposed method can be used easily and have little interference.","PeriodicalId":72689,"journal":{"name":"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference","volume":"24 1","pages":"2771-4"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measuring cervical vertebra movements using kinect sensor.\",\"authors\":\"Xiaolong Ma, Guanghua Xu, Min Li, Jun Xie, Longting Chen, Wei Pei\",\"doi\":\"10.1109/EMBC.2015.7318966\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The incidence of cervical vertebra spondylosis is increasing with the pace of life while there is no high-efficient measurement method. This study proposed a non-contact, high-efficient, and high-precisionmethod measuring the cervical vertebra activities which obtains the cervical vertebra activities by combining the function of skeletal tracking and face tracking. A comparison study between the proposed and traditional methods has been conducted here. Statistics shows that the efficiency of the proposed measurement method at least is 6 times faster than modified square shaped goniometers that is the represent of traditional measurement, and it's angular error in average is 0.35°. Moreover, the proposed measuring method has been tested in hospital clinical environment and the results show that the proposed method can be used easily and have little interference.\",\"PeriodicalId\":72689,\"journal\":{\"name\":\"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference\",\"volume\":\"24 1\",\"pages\":\"2771-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMBC.2015.7318966\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBC.2015.7318966","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着生活节奏的加快,颈椎病的发病率越来越高,但目前尚无高效的测量方法。本研究提出了一种非接触、高效、高精度的颈椎活动测量方法,将骨骼跟踪和面部跟踪功能相结合,获得颈椎活动数据。本文对所提出的方法与传统方法进行了比较研究。统计表明,该测量方法的测量效率比传统测量方法的代表——改进的方形测角仪至少快6倍,平均角度误差为0.35°。此外,所提出的测量方法已在医院临床环境中进行了测试,结果表明该方法易于使用,干扰小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measuring cervical vertebra movements using kinect sensor.
The incidence of cervical vertebra spondylosis is increasing with the pace of life while there is no high-efficient measurement method. This study proposed a non-contact, high-efficient, and high-precisionmethod measuring the cervical vertebra activities which obtains the cervical vertebra activities by combining the function of skeletal tracking and face tracking. A comparison study between the proposed and traditional methods has been conducted here. Statistics shows that the efficiency of the proposed measurement method at least is 6 times faster than modified square shaped goniometers that is the represent of traditional measurement, and it's angular error in average is 0.35°. Moreover, the proposed measuring method has been tested in hospital clinical environment and the results show that the proposed method can be used easily and have little interference.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信