有源电力滤波器电流环数字PI控制研究

Xueliang Wei
{"title":"有源电力滤波器电流环数字PI控制研究","authors":"Xueliang Wei","doi":"10.1109/ICECE.2010.1041","DOIUrl":null,"url":null,"abstract":"With development of modern industry, more and more non-linear loads are used in power system, resulting in increasingly severe harmonic pollution. Harmonic becomes main factors affecting power quality. Active power filter, as the most effective method to eliminate harmonic, has been paid more and more attention recently. The current compensation performance of active power filter depends on the controller. At present, more and more active power filters have been controlled by digital controller, which has the advantage of flexible control strategy, powerful ability of signal processing. However, digital controller has inherent drawbacks, such as quantization error, signal delay caused by Zero-Order hold, sample and computation delay. With analyzing active power filter's decreased performance caused by digital controller, this paper concentrates on two reasons: Zero-Order hold, sample and computation delay.","PeriodicalId":6419,"journal":{"name":"2010 International Conference on Electrical and Control Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"57","resultStr":"{\"title\":\"Study on Digital PI Control of Current Loop in Active Power Filter\",\"authors\":\"Xueliang Wei\",\"doi\":\"10.1109/ICECE.2010.1041\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With development of modern industry, more and more non-linear loads are used in power system, resulting in increasingly severe harmonic pollution. Harmonic becomes main factors affecting power quality. Active power filter, as the most effective method to eliminate harmonic, has been paid more and more attention recently. The current compensation performance of active power filter depends on the controller. At present, more and more active power filters have been controlled by digital controller, which has the advantage of flexible control strategy, powerful ability of signal processing. However, digital controller has inherent drawbacks, such as quantization error, signal delay caused by Zero-Order hold, sample and computation delay. With analyzing active power filter's decreased performance caused by digital controller, this paper concentrates on two reasons: Zero-Order hold, sample and computation delay.\",\"PeriodicalId\":6419,\"journal\":{\"name\":\"2010 International Conference on Electrical and Control Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"57\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Electrical and Control Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECE.2010.1041\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Electrical and Control Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECE.2010.1041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 57

摘要

随着现代工业的发展,电力系统中使用的非线性负荷越来越多,造成的谐波污染日益严重。谐波已成为影响电能质量的主要因素。有源电力滤波器作为消除谐波最有效的方法,近年来越来越受到人们的重视。有源电力滤波器的电流补偿性能取决于控制器。目前,越来越多的有源电力滤波器采用数字控制器控制,具有控制策略灵活、信号处理能力强等优点。然而,数字控制器有其固有的缺点,如量化误差、零阶保持引起的信号延迟、采样和计算延迟。分析了数字控制器导致有源电力滤波器性能下降的原因,重点分析了零阶保持、采样和计算延迟两个方面的原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on Digital PI Control of Current Loop in Active Power Filter
With development of modern industry, more and more non-linear loads are used in power system, resulting in increasingly severe harmonic pollution. Harmonic becomes main factors affecting power quality. Active power filter, as the most effective method to eliminate harmonic, has been paid more and more attention recently. The current compensation performance of active power filter depends on the controller. At present, more and more active power filters have been controlled by digital controller, which has the advantage of flexible control strategy, powerful ability of signal processing. However, digital controller has inherent drawbacks, such as quantization error, signal delay caused by Zero-Order hold, sample and computation delay. With analyzing active power filter's decreased performance caused by digital controller, this paper concentrates on two reasons: Zero-Order hold, sample and computation delay.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信