牙科用Au50-Ag25-Pd25和Ni88.6-Cr11.4合金的腐蚀行为比较

IF 2.9 Q2 ELECTROCHEMISTRY
Irfan Liaquat, A. Ziya, Athar Ibrahim, Urva Malik, Gao Qilong, Muhammad Danial
{"title":"牙科用Au50-Ag25-Pd25和Ni88.6-Cr11.4合金的腐蚀行为比较","authors":"Irfan Liaquat, A. Ziya, Athar Ibrahim, Urva Malik, Gao Qilong, Muhammad Danial","doi":"10.5599/jese.1931","DOIUrl":null,"url":null,"abstract":"The electrochemical behaviour of alloys (Au50-Ag25-Pd25 and Ni88.6-Cr11.4) was studied in Fusayama's artificial saliva at pH 6.5 and 37 °C by using open circuit potential, electro­chemical impedance spectroscopy, and potentiodynamic polarization measure­ments. Electrochemical impedance spectroscopy results were simulated with an equivalent electrical circuit. After immersion in artificial saliva, surface characterization of samples was done using scanning electron microscopy connected with energy-dispersive spectro­scopy. All obtained results revealed that Au50-Ag25-Pd25 alloy is much more resistive than Ni88.6-Cr11.4 and can be recommended for the effective treatment of patients with dental prosthetics that have metal frameworks.\ns.","PeriodicalId":15660,"journal":{"name":"Journal of Electrochemical Science and Engineering","volume":"1 1","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2023-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative corrosion behavior of Au50-Ag25-Pd25 and Ni88.6-Cr11.4 alloys utilized in dental applications\",\"authors\":\"Irfan Liaquat, A. Ziya, Athar Ibrahim, Urva Malik, Gao Qilong, Muhammad Danial\",\"doi\":\"10.5599/jese.1931\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The electrochemical behaviour of alloys (Au50-Ag25-Pd25 and Ni88.6-Cr11.4) was studied in Fusayama's artificial saliva at pH 6.5 and 37 °C by using open circuit potential, electro­chemical impedance spectroscopy, and potentiodynamic polarization measure­ments. Electrochemical impedance spectroscopy results were simulated with an equivalent electrical circuit. After immersion in artificial saliva, surface characterization of samples was done using scanning electron microscopy connected with energy-dispersive spectro­scopy. All obtained results revealed that Au50-Ag25-Pd25 alloy is much more resistive than Ni88.6-Cr11.4 and can be recommended for the effective treatment of patients with dental prosthetics that have metal frameworks.\\ns.\",\"PeriodicalId\":15660,\"journal\":{\"name\":\"Journal of Electrochemical Science and Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electrochemical Science and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5599/jese.1931\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrochemical Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5599/jese.1931","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

摘要

采用开路电位、电化学阻抗谱和动电位极化测量等方法研究了Au50-Ag25-Pd25和Ni88.6-Cr11.4合金在pH 6.5和37℃条件下在Fusayama人工唾液中的电化学行为。用等效电路对电化学阻抗谱结果进行了模拟。在人工唾液中浸泡后,用扫描电镜结合能量色散光谱对样品进行表面表征。结果表明,Au50-Ag25-Pd25合金具有比Ni88.6-Cr11.4更高的电阻性,可推荐用于具有金属框架的修复体患者的有效治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative corrosion behavior of Au50-Ag25-Pd25 and Ni88.6-Cr11.4 alloys utilized in dental applications
The electrochemical behaviour of alloys (Au50-Ag25-Pd25 and Ni88.6-Cr11.4) was studied in Fusayama's artificial saliva at pH 6.5 and 37 °C by using open circuit potential, electro­chemical impedance spectroscopy, and potentiodynamic polarization measure­ments. Electrochemical impedance spectroscopy results were simulated with an equivalent electrical circuit. After immersion in artificial saliva, surface characterization of samples was done using scanning electron microscopy connected with energy-dispersive spectro­scopy. All obtained results revealed that Au50-Ag25-Pd25 alloy is much more resistive than Ni88.6-Cr11.4 and can be recommended for the effective treatment of patients with dental prosthetics that have metal frameworks. s.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
27.30%
发文量
90
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信